The quartz crystal microbalance (QCM) is an ultra-sensitive measuring device and has been commonly used in many specific applications. The mass sensitivity distribution curve of m-m type QCM (QCM with symmetrical electrode) is a Gaussian distribution. However, achieving highly accurate and repeatable measurements requires the uniform distribution of mass sensitivity. To improve the uniformity of QCM mass sensitivity while ensuring high absolute mass sensitivity, the double-ring electrode geometry is designed. This study improves the size design of the double-ring electrode, and reveals the rules for varying sensitivity and electrode parameters based on a mathematical model. Through analyzing the mass sensitivity distribution of different electrode structures of QCMs, the uniformity of the double-ring electrode QCM is proved. The effects of mass sensitivity distribution of QCM are studied using the finite element method (FEM) by the variation of the size of electrodes, and an optimal size of electrode was discovered. Our results show that the double-ring type QCM has better uniformity of the mass sensitivity distribution and it can maintain the high mass sensitivity when the size of the inner ring of the double-ring electrode is close to half of the size of the outer ring. Meanwhile, there is an optimal outer radius that enables us to obtain an ideal and desirable displacement distribution. The numerical simulation results provide design ideas for the physical design of the double-ring type QCM.
Uniformization of mass sensitivity distribution is conducive to the application of the quartz crystal microbalance (QCM) in some fields. However, the sensitivity of the QCM sensor surface perpendicular to the displacement direction is higher that of the displacement direction in the mass sensitivity distribution of ring and double-ring QCMs, which leads to poor reproducibility of the sensor. Considering the effect of the electrode structure on the mass sensitivity distribution, we found that for ring- and double-ring-type QCMs, when the elliptical single ring and double-ring electrode structures are combined, an approximately uniform mass sensitivity can be obtained in all directions. Therefore, this study proposes the elliptical single-ring and elliptical double-ring electrode structure design. Through theoretical calculations and three-dimensional finite element analysis verification, a systematic investigation is carried out to quantify the effect of the ratio of the minor axis to the major axis of the elliptical electrode on the mass sensitivity distribution in different directions, and the optimal ratio is found to be 0.8. Comparing the mass sensitivity of the new type of electrodes and the original electrodes, the result shows that the mass sensitivity distribution of the elliptical double-ring electrode structure is more uniform. Hence, these specially designed electrodes are conducive to improving the repeatability.
Introduction: For patients with schizophrenia, clozapine (CLZ) in combination with clonazepam (CLNAZ) is one of the viable therapeutic options. We successfully reduced the doses of CLZ and CLNAZ to the safe range of a polydrug abuse patient. As far as we know, this is the first case of this problem. As there are no relevant guidelines to reduce CLZ or CLNAZ, we hope to share this case to provide a reference for the prevention and treatment of similar patients with multidrug abuse. Case Presentation: This case report describes a 46-year-old male with a 24-year history of schizophrenia. His main clinical manifestations are auditory hallucinations, persecutory delusion, and emotional instability. In 2012, the patient started taking rifampicin due to tuberculosis and gradually overused CLZ and CLNAZ. Before admission, he took 1,275 mg of CLZ every day and 26 mg of CLNAZ every night. With the help of Therapeutic Drug Monitoring (TDM) and pharmacogenetic testing, we gradually reduced his daily dose of CLZ and CLNAZ and formulated a more reasonable dosing schedule for him. At the time of discharge, the patient took CLZ 450 mg per day and CLNAZ 2 mg per night, with no obvious symptoms of psychosis. Conclusion: In the process of drug maintenance treatment of schizophrenia, it is necessary to adopt TDM strategy to reduce and treat the abuse of multiple prescription drugs.
1 November 2021 in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
EEG can be used to characterize the electrical activity of the cerebral cortex, but it is also susceptible to interference. Compared with the other artifacts, Electrooculogram (EOG) artifacts have a greater impact on EEG processing and are more difficult to remove. Here, we mainly compared the regression and ICA algorithms both based on the EOG channels for the effect of removing EOG artifacts in the Stroop experiment of methamphetamine addicts. From the perspective of time domain and power spectral density, the ICA algorithm based on the EOG channels is more effective. However, the regression algorithm based on the EOG channels is less complex, more time-saving, and more suitable for real-time tasks.Clinical Relevance— For clinical purposes, this research has a certain reference value for selecting appropriate methods of removing EOG artifacts when processing the EEG of methamphetamine addicts.