Unsteady flow is highly related to flow loss and aerodynamic performance degradation in the axial compressor. In this paper, the dynamic mode decomposition method was used to investigate in-depth flow structures and related evolutionary mechanisms of the internal flow field. Four main flow structures were observed through flow field decoupling: the oscillation of the tip leakage vortex (TLV) region, the circumferential migration of the leakage-induced vortex (LIV), the axial migration of the rear part of the leakage vortex (RLV), and the oscillation of the leading edge vortex (LEV). All of those four structures indicated the presence of internal high disturbance regions. The reconstruction of the dominant mode flow field revealed that the unsteady evolutionary mechanism of the flow field mainly consisted of two components: the axial evolution of the RLV and the circumferential evolution of the LIV. It was further revealed that the axial evolution of the RLV was the primary reason for the formation of low-energy fluid mass within the passage; under the influence of the “leading edge overflow,” the LIV eventually fused with the LEV. The blocking effect of the LEV led to the formation of a high oscillation region at the leading edge of the adjacent blade pressure surface, resulting in a synchronous moment between the emergence of the LIV and the LEV. The analysis of the two unsteady evolution mechanism components further supported TLV breakdown as the main cause of flow unsteadiness. This study laid the foundation for further accurate flow unsteadiness control.
It is of great value to study the impact of abnormal blade installation angle on the inducement mechanism of rotating stall to achieve the active control of rotating stall in an axial fan. Based on throttle value function and SST k-ω turbulence model, numerical simulations of the unsteady flow process in stall condition of an axial flow fan with adjustable vanes were carried out, and the influence mechanism of abnormal stagger angle of a single blade in the second stage rotor on induced position and type of stall inception and evolution process of rotating stall were analyzed. The results show that compared with synchronous adjustment of blade angle, the blade with abnormal stagger angle will cause the increase of flow rate at the beginning of stall and make the fan fall into an unstable condition in advance. The existence of blade with abnormal angle does not cause the change of the induced position and type of stall inception and the inducement mechanism of rotating stall, which are the same as the axial fan with normal blade angle. Moreover, the single blade with abnormal deviation angle has important impacts on the 3D unsteady evolution process from stall inception to stall cell formation in two rotors.
20 November 2013 in Chinese Journal of Mechanical Engineering
Current studies of fan performance optimization mainly focus on two aspects: one is to improve the blade profile, and another is only to consider the influence of single impeller structural parameter on fan performance. However, there are few studies on the comprehensive effect of the key parameters such as blade number, exit stagger angle of blade and the impeller outlet width on the fan performance. The G4-73 backward centrifugal fan widely used in power plants is selected as the research object. Based on orthogonal design and BP neural network, a model for predicting the centrifugal fan performance parameters is established, and the maximum relative errors of the total pressure and efficiency are 0.974% and 0.333%, respectively. Multi-objective optimization of total pressure and efficiency of the fan is conducted with genetic algorithm, and the optimum combination of impeller structural parameters is proposed. The optimized parameters of blade number, exit stagger angle of blade and the impeller outlet width are seperately 14, 43.9°, and 21 cm. The experiments on centrifugal fan performance and noise are conducted before and after the installation of the new impeller. The experimental results show that with the new impeller, the total pressure of fan increases significantly in total range of the flow rate, and the fan efficiency is improved when the relative flow is above 75%, also the high efficiency area is broadened. Additionally, in 65% −100% relative flow, the fan noise is reduced. Under the design operating condition, total pressure and efficiency of the fan are improved by 6.91% and 0.5%, respectively. This research sheds light on the considering of comprehensive effect of impeller structrual parameters on fan performance, and a new impeller can be designed to satisfy the engineering demand such as energy-saving, noise reduction or solving air pressure insufficiency for power plants.
Due to the nonlinear behavior of carbon dioxide properties at its critical point and the size effect of the supercritical carbon dioxide (S-CO2) centrifugal compressor, the stall causation mechanism differs between the S-CO2 centrifugal compressor and a conventional air compressor. The comprehension of the induced principle of the S-CO2 compressor rotating stall holds immense significance in enhancing stall margin and efficiency. This paper employs unsteady simulations to investigate the causes of the impeller rotating stall in the S-CO2 centrifugal compressor. The results show that the leading edge breakdown vortex (LEBV) formed by the tip leakage vortex (TLV) breakdown and the reverse flow in the passage are the reasons for blocking the passage and ultimately causing the rotating stall of the impeller. The migration motion of the LEBV not only induces the leading edge spillage phenomenon but also influences the intensity of the tip leakage flow (TLF) in adjacent passages, causing the propagation of the TLV breakdown phenomenon in the opposite direction to that of impeller rotation. The TLV undergoes intermittent breakdown in flow field, which is influenced by variations in TLF intensity. Additionally, there is a preceding process of breakdown-induced vortex formation and disappearance prior to TLV fragmentation.
Rotating stalls are generally the first instability met in turbomachinery, before surges. This 3D phenomenon is characterized by one or more stalled flow cells which rotate at a fraction of the impeller speed. The goal of the present work is to shed some light on the entropy generation in a centrifugal fan under rotating stall conditions. A numerical simulation of entropy generation is carried out with the ANSYS Fluent software which solves the Navier-Stokes equations and user defined function (UDF). The entropy generation characteristics in the centrifugal fan for five typical conditions are presented and discussed, involving the design condition, conditions on occurrence and development of stall inception, the rotating stall conditions with two throttle coefficients. The results show that the entropy generation increases after the occurrence of stall inception. The high entropy generation areas move along the circumferential and axial directions, and finally merge into one stall cell. The entropy generation rate during circumferential propagation of the stall cell is also discussed, showing that the entropy generation history is similar to sine curves in impeller and volute, and the volute tongue has a great influence on entropy generation in the centrifugal fan.
Tip leakage vortex breakdown, as a strong unsteady phenomenon, is recognized as an important inducing factor for compressor rotating stall. In this study, a validated numerical simulation was conducted to analyze the impact and control mechanism of synthetic jets on the performance of a transonic compressor from the perspective of tip leakage vortex breakdown suppression. The results indicate that the baseline compressor's stall mechanism is as follows: under near stall condition, an unsteady flow process dominated by the tip leakage vortex breakdown exists in the blade tip. During this process, the flow capacity diminishes, leading to an emergence of leading-edge spillage, which subsequently triggers rotating stall. Synthetic jets yield considerable improvement in the compressor performance. In cases synthetic jets positioned at 25%, Cax achieves a maximum improvement of 10.97% in the stability margin, while synthetic jets placed at 50% Cax gives an improvement of peak efficiency by 0.82%. The mechanism for performance improvement is as follows: synthetic jets suppress the vortex breakdown, disrupt the inherent feedback mechanism in the tip flow field, and reduce the blockage within the passage, thereby achieving an extension of the stability margin. Specifically, during the injection phase, an induced vortex suppresses the breakdown of the tip leakage vortex, thereby reducing the blade loading. In the suction phase, the tip leakage flow is reduced, which weakens the recirculation zone and causes the interface between the mainstream and the leakage flow to shift downstream. This research provides technical support for the development and optimization of efficient, wide-margin compressors.