Producers have to guarantee the extra virgin olive oil (EVOO) quality characteristics reported in the Regulation (CEE) 2568/91 throughout the product shelf-life (SL). Unfortunately, due to the development of oxidative reactions, some quality indices change during storage leading to a progressive deterioration of EVOO quality. To avoid the risk of product downgrading in the virgin oil category, the development of effective shelf-life prediction models is extremely important for the olive oil industry. In this research, the accelerated shelf-life testing (ASLT) protocol was applied to evaluate the temperature dependence of selected oxidation indexes as well as to develop a shelf-life predictive model. The evolution of conventional (peroxide value, K232, K270, polyphenols, tocopherols and hexanal) and unconventional parameters (conjugated trienes and pyropheophytin a) was monitored in bottled EVOO stored in the dark at increasing temperature (25, 40, 50 and 60 °C). Accordingly, for well-packed products with reduced oxygen in headspace, the best shelf-life index allowing the ability to predict EVOO SL turned out to be K270. In addition, pyropheophytin a (%) has been shown to be more sensitive to temperature changes than the secondary oxidation indices, thus suggesting its use as a freshness indicator for storage temperatures higher than 25 °C.
A method based on the selective extraction of zearalenone (ZON) from edible vegetable oils using molecularly imprinted polymer (MIP) has been developed and validated. Ultra-high-pressure liquid chromatography coupled with a fluorescence detection system was employed for the detection of zearalenone. The method was applied to the analysis of zearalenone in maize oil samples spiked at four concentration levels within the maximum permitted amount specified by the European Commission Regulation (EC) No. 1126/2007. As a result, the proposed methodology provided high recoveries (>72%) with good linearity (R2 > 0.999) in the range of 10–2000 μg/kg and a repeatability relative standard deviation below 1.8%. These findings meet the analytical performance criteria specified by the European Commission Regulation No. 401/2006 and reveal that the proposed methodology can be successfully applied for monitoring zearalenone at trace levels in different edible vegetable oils. A comparison of MIP behavior with the ones of QuEChERS and liquid–liquid extraction was also performed, showing higher extraction rates and precision of MIP. Finally, the evolution of ZON contamination during the maize oil refining process was also investigated, demonstrating how the process is unable to completely remove (60%) ZON from oil samples.
The fatty acid (FA) composition of fats and oils is commonly determined by gas chromatography after preparing fatty acid methyl esters (FAME). Capillary columns coated with polyethylene glycol (PEG) emerged as the preferred separation tool for the quantification of the polyunsaturated fatty acids (PUFA) contained primarily in marine oils. However, their selectivity is inadequate for measuring the trans fatty acids (TFA) contained in refined vegetable oils, dairy fats, and ultimately marine oils. Highly polar 100% poly(biscyanopropyl siloxane) (BCS) capillary columns provide the necessary selectivity, but small differences in the phase polarity caused by column age, conditioning, or manufacturing variations affect the reproducibility of their separations of these complex samples. In this study, a simple procedure is described to compensate for small variations in column selectivity by adjusting the elution temperature. The balance between the dipole-induced dipole interactions (DIDI) and dispersive interactions (DI) was determined by measuring Selectivity Factors (SF(i)), corresponding to the elution of an unsaturated FAME such as 18:3n-3 relative to two saturated FAME such as 20:0 and 22:0. Knowing the SF(i) provided by the installed capillary column at a given elution temperature, and the SF(i) of the target separation, we propose a simple calculation to determine the necessary elution temperature adjustment to achieve (or restore) the desired separation. After determining the SF(i) which provides the optimal separation of TFA, the novel methodology was applied to the separation of refined vegetable oils, butter fats, and marine oils.
Minor compounds in vegetable oils are distributed between free and esterified forms, and the ratio of these two fractions could represent an important parameter for assessment of oil authenticity. A simple method based on offline SPE-GC-FID for the analysis of free and esterified hydroxylated minor compounds in olive and sunflower oils has been developed and in-house validated. A satisfactory repeatability relative standard deviation (<7.5%) was obtained in all cases. The method, which requires simple instrumentation, allows for reliable quantification in a single chromatographic run with the advantages of minimizing sample manipulation, use of toxic solvents and reagents, and time consumption. The analytical procedure was applied to pure oil samples, including 15 authentic extra virgin olive oils collected from different European countries (Spain, Italy, Greece, and Portugal). Finally, the proposed SPE-GC-FID methodology could detect changes in the ratio between the free and esterified forms in pure extra virgin olive oil when mixed with refined sunflower oil at different percentages of 2, 5, 10, 15, and 20% (w/w) to simulate adulteration.
The evaluation of the content of waxes is request both by IOC Trade Standard and by Regulation (EEC) 2568/91 and its further amendments. The official method uses 15 g of silicic acid and elutes several fractions by using huge volumes of dangerous solvent (n-hexane). The developed method uses 1 g of silicic acid with a different particle size and less than 20 mL of solvent mixture, substituting n-hexane with less toxic isooctane. Briefly, after spiking with a suitable internal standard, oil sample is fractionated by SPE (Solid Phase Extraction) cartridge with 1 g of silica, waxes are eluted with 14 mL of isooctane/ethyl ether 99/1 (6 mL discarded and 8 mL collected), then, after elution sample is reconstitute in 200 μL of n-heptane and analysed by capillary GC. Data of “In home” validation, (repeatability, accuracy and recovery) and relative chromatograms are reported in this paper.