Nicolina Sciaraffa

Dr. Nicolina Sciaraffa

Department of Molecular Medicine, Sapienza University of Rome, 00185 Rome, Italy

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AGAndrea Giorgi
Andrea Giorgi
VRVincenzo Ronca
Vincenzo Ronca
AVAlessia Vozzi
Alessia Vozzi
Nicolina SciaraffaNicolina Sciaraffa
Nicolina Sciaraffa
AFAntonello di Florio
Antonello di Florio
Gianluca BorghiniGianluca Borghini
Gianluca Borghini
The capability of monitoring user’s performance represents a crucial aspect to improve safety and efficiency of several human-related activities. Human errors are indeed among the major causes of work-related accidents. Assessing human factors (HFs) could prevent these accidents through specific neurophysiological signals’ evaluation but laboratory sensors require highly-specialized operators and imply a certain grade of invasiveness which could negatively interfere with the worker’s activity. On the contrary, consumer wearables are characterized by their ease of use and their comfortability, other than being cheaper compared to laboratory technologies. Therefore, wearable sensors could represent an ideal substitute for laboratory technologies for a real-time assessment of human performances in ecological settings. The present study aimed at assessing the reliability and capability of consumer wearable devices (i.e., Empatica E4 and Muse 2) in discriminating specific mental states compared to laboratory equipment. The electrooculographic (EOG), electrodermal activity (EDA) and photoplethysmographic (PPG) signals were acquired from a group of 17 volunteers who took part to the experimental protocol in which different working scenarios were simulated to induce different levels of mental workload, stress, and emotional state. The results demonstrated that the parameters computed by the consumer wearable and laboratory sensors were positively and significantly correlated and exhibited the same evidences in terms of mental states discrimination.

29 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
HZHong Zeng
Hong Zeng
XLXiuFeng Li
XiuFeng Li
Gianluca BorghiniGianluca Borghini
Gianluca Borghini
YZYue Zhao
Yue Zhao
Pietro AricòPietro Aricò
Pietro Aricò
Fabio BabiloniFabio Babiloni
Fabio Babiloni
Fatigued driving is one of the main causes of traffic accidents. The electroencephalogram (EEG)-based mental state analysis method is an effective and objective way of detecting fatigue. However, as EEG shows significant differences across subjects, effectively “transfering” the EEG analysis model of the existing subjects to the EEG signals of other subjects is still a challenge. Domain-Adversarial Neural Network (DANN) has excellent performance in transfer learning, especially in the fields of document analysis and image recognition, but has not been applied directly in EEG-based cross-subject fatigue detection. In this paper, we present a DANN-based model, Generative-DANN (GDANN), which combines Generative Adversarial Networks (GAN) to enhance the ability by addressing the issue of different distribution of EEG across subjects. The comparative results show that in the analysis of cross-subject tasks, GDANN has a higher average accuracy of 91.63% in fatigue detection across subjects than those of traditional classification models, which is expected to have much broader application prospects in practical brain–computer interaction (BCI).

10 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AVAlessia Vozzi
Alessia Vozzi
VRVincenzo Ronca
Vincenzo Ronca
Pietro AricòPietro Aricò
Pietro Aricò
Gianluca BorghiniGianluca Borghini
Gianluca Borghini
Nicolina SciaraffaNicolina Sciaraffa
Nicolina Sciaraffa
Gianluca Di FlumeriGianluca Di Flumeri
Gianluca Di Flumeri
The sample size is a crucial concern in scientific research and even more in behavioural neurosciences, where besides the best practice it is not always possible to reach large experimental samples. In this study we investigated how the outcomes of research change in response to sample size reduction. Three indices computed during a task involving the observations of four videos were considered in the analysis, two related to the brain electroencephalographic (EEG) activity and one to autonomic physiological measures, i.e., heart rate and skin conductance. The modifications of these indices were investigated considering five subgroups of sample size (32, 28, 24, 20, 16), each subgroup consisting of 630 different combinations made by bootstrapping n (n = sample size) out of 36 subjects, with respect to the total population (i.e., 36 subjects). The correlation analysis, the mean squared error (MSE), and the standard deviation (STD) of the indexes were studied at the participant reduction and three factors of influence were considered in the analysis: the type of index, the task, and its duration (time length). The findings showed a significant decrease of the correlation associated to the participant reduction as well as a significant increase of MSE and STD (p < 0.05). A threshold of subjects for which the outcomes remained significant and comparable was pointed out. The effects were to some extents sensitive to all the investigated variables, but the main effect was due to the task length. Therefore, the minimum threshold of subjects for which the outcomes were comparable increased at the reduction of the spot duration.

21 July 2017 in Brain Sciences
Verified
Journal Article
Open access
PDF file
Nicolina SciaraffaNicolina Sciaraffa
Nicolina Sciaraffa
GBGianluca Borghini
Gianluca Borghini
Pietro AricòPietro Aricò
Pietro Aricò
Gianluca Di FlumeriGianluca Di Flumeri
Gianluca Di Flumeri
ACAlfredo Colosimo
Alfredo Colosimo
Fabio BabiloniFabio Babiloni
Fabio Babiloni
Subjects’ interaction is the core of most human activities. This is the reason why a lack of coordination is often the cause of missing goals, more than individual failure. While there are different subjective and objective measures to assess the level of mental effort required by subjects while facing a situation that is getting harder, that is, mental workload, to define an objective measure based on how and if team members are interacting is not so straightforward. In this study, behavioral, subjective and synchronized electroencephalographic data were collected from couples involved in a cooperative task to describe the relationship between task difficulty and team coordination, in the sense of interaction aimed at cooperatively performing the assignment. Multiple-brain connectivity analysis provided information about the whole interacting system. The results showed that averaged local properties of a brain network were affected by task difficulty. In particular, strength changed significantly with task difficulty and clustering coefficients strongly correlated with the workload itself. In particular, a higher workload corresponded to lower clustering values over the central and parietal brain areas. Such results has been interpreted as less efficient organization of the network when the subjects’ activities, due to high workload tendencies, were less coordinated.

15 January 2020 in Brain Sciences
Verified
Journal Article
Open access
PDF file
MSMarika Sebastiani
Marika Sebastiani
Gianluca Di FlumeriGianluca Di Flumeri
Gianluca Di Flumeri
Pietro AricòPietro Aricò
Pietro Aricò
Nicolina SciaraffaNicolina Sciaraffa
Nicolina Sciaraffa
Fabio BabiloniFabio Babiloni
Fabio Babiloni
Gianluca BorghiniGianluca Borghini
Gianluca Borghini
Vigilance degradation usually causes significant performance decrement. It is also considered the major factor causing the out-of-the-loop phenomenon (OOTL) occurrence. OOTL is strongly related to a high level of automation in operative contexts such as the Air Traffic Management (ATM), and it could lead to a negative impact on the Air Traffic Controllers’ (ATCOs) engagement. As a consequence, being able to monitor the ATCOs’ vigilance would be very important to prevent risky situations. In this context, the present study aimed to characterise and assess the vigilance level by using electroencephalographic (EEG) measures. The first study, involving 13 participants in laboratory settings allowed to find out the neurophysiological features mostly related to vigilance decrements. Those results were also confirmed under realistic ATM settings recruiting 10 professional ATCOs. The results demonstrated that (i) there was a significant performance decrement related to vigilance reduction; (ii) there were no substantial differences between the identified neurophysiological features in controlled and ecological settings, and the EEG-channel configuration defined in laboratory was able to discriminate and classify vigilance changes in ATCOs’ vigilance with high accuracy (up to 84%); (iii) the derived two EEG-channel configuration was able to assess vigilance variations reporting only slight accuracy reduction.

8 April 2020 in Brain Sciences
Verified
Journal Article
Open access
PDF file
Nicolina SciaraffaNicolina Sciaraffa
Nicolina Sciaraffa
MKManousos Klados
Manousos Klados
Gianluca BorghiniGianluca Borghini
Gianluca Borghini
Gianluca Di FlumeriGianluca Di Flumeri
Gianluca Di Flumeri
Fabio BabiloniFabio Babiloni
Fabio Babiloni
Pietro AricòPietro Aricò
Pietro Aricò
The need for automatic detection and classification of high-frequency oscillations (HFOs) as biomarkers of the epileptogenic tissue is strongly felt in the clinical field. In this context, the employment of artificial intelligence methods could be the missing piece to achieve this goal. This work proposed a double-step procedure based on machine learning algorithms and tested it on an intracranial electroencephalogram (iEEG) dataset available online. The first step aimed to define the optimal length for signal segmentation, allowing for an optimal discrimination of segments with HFO relative to those without. In this case, binary classifiers have been tested on a set of energy features. The second step aimed to classify these segments into ripples, fast ripples and fast ripples occurring during ripples. Results suggest that LDA applied to 10 ms segmentation could provide the highest sensitivity (0.874) and 0.776 specificity for the discrimination of HFOs from no-HFO segments. Regarding the three-class classification, non-linear methods provided the highest values (around 90%) in terms of specificity and sensitivity, significantly different to the other three employed algorithms. Therefore, this machine-learning-based procedure could help clinicians to automatically reduce the quantity of irrelevant data.