Ivan Hafner

Mr. Ivan Hafner

Faculty of Civil Engineering, University of Zagreb
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
LLLuka Lulić
Luka Lulić
KOKarlo Ožić
Karlo Ožić
Tomislav KišičekTomislav Kišiček
Tomislav Kišiček
IHIvan Hafner
Ivan Hafner
Mislav StepinacMislav Stepinac
Mislav Stepinac
In the wake of recent strong earthquakes in Croatia, there is a need for a detailed and more comprehensive post-earthquake damage assessment. Given that masonry structures are highly vulnerable to horizontal actions caused by earthquakes and a majority of the Croatian building stock is made of masonry, this field is particularly important for Croatia. In this paper, a complete assessment of an educational building in Zagreb Lower Town is reported. An extensive program of visual inspection and geometrical surveys has been planned and performed. Additionally, an in situ shear strength test is presented. After extensive fieldwork, collected data and results were input in 3Muri software for structural modeling. Moreover, a non-linear static (pushover) analysis was performed to individuate the possible failure mechanisms and to compare real-life damage to software results.

25 February 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Mislav StepinacMislav Stepinac
Mislav Stepinac
Tomislav KišičekTomislav Kišiček
Tomislav Kišiček
TRTvrtko Renić
Tvrtko Renić
IHIvan Hafner
Ivan Hafner
Chiara BedonChiara Bedon
Chiara Bedon
Masonry structures are notoriously vulnerable to horizontal actions caused by earthquakes. Given the high seismicity of the European region, and that the European building stock comprises a lot of masonry buildings, knowledge about their structural response to seismic excitation is particularly important, but at the same time difficult to determine, due to the heterogenous nature of materials and/or constructional techniques in use. An additional issue is represented by the current methods for mechanical properties assessment, that do not provide a reliable framework for accurate structural estimations of existing buildings characterized by different typological properties. Every structure, in other words, should be separately inspected in regard to its mechanical behaviour, based on dedicated approaches able to capture potential critical issues. In this review paper, an insight on the Croatian ARES project is presented (Assessment and Rehabilitation of Existing Structures), including a state-of-the-art of the actual building stock and giving evidence of major difficulties concerning the assessment of existing structures. The most commonly used techniques and tools are compared, with a focus on their basic features and field of application. A brief overview of prevailing structural behaviours and Finite Element numerical modelling issues are also mentioned. As shown, the general tendency is to ensure “sustainable” and energy-efficient building systems. The latter, however, seem in disagreement with basic principles of structural maintenance and renovation. The aim of the ongoing ARES project, in this context, is to improve the current knowledge regarding the assessment and strengthening of structures, with a focus on a more reliable design and maintenance process for existing masonry buildings.

13 June 2023 in Buildings
Verified
Journal Article
Open access
PDF file
IHIvan Hafner
Ivan Hafner
Tomislav KišičekTomislav Kišiček
Tomislav Kišiček
Matija GamsMatija Gams
Matija Gams
The seismic strengthening of buildings in earthquake-prone areas has been a hot topic in recent years, especially for masonry structures. Because there are so many masonry structures and because most were built before seismic codes existed, their seismic vulnerability is an unavoidable issue. Over the years, several methods for seismic strengthening of masonry piers and walls have been developed that may roughly be classified as traditional or modern. In this paper, an overview of the most commonly used and effective methods will be presented with an emphasis on modern methods based on a Fabric-Reinforced Cementitious Matrix. The advantages and disadvantages will be discussed from the point of view of usability, feasibility, and effectiveness. Finally, a comparison will be drawn between traditional and new methods based on composite materials.

8 March 2022 in Buildings
Verified
Journal Article
Open access
PDF file
IHIvan Hafner
Ivan Hafner
DLDamir Lazarević
Damir Lazarević
Tomislav KišičekTomislav Kišiček
Tomislav Kišiček
Mislav StepinacMislav Stepinac
Mislav Stepinac
After the Zagreb earthquakes in March 2020, around 25,000 buildings were estimated damaged, most of them being in the historic city center. This fact is not that surprising since most of the city center buildings are unreinforced masonry structures that have not been assessed in quite some time and usually no retrofitting methods were ever applied. The rapid post-disaster assessment began the same day after the first earthquake occurred. Through mostly visual assessment methods, the basic idea is to identify the safety and usability of buildings in general. This type of assessment was also conducted in one of the oldest Croatian cultural institutions, Matica Hrvatska. It is a building of great historical significance and cultural value, as is most of the city center. Accordingly, this building was constructed with no consideration given to seismic events and with the use of traditional materials and building techniques. In the scope of this paper, urgent actions that were taken are shown with problems and challenges that occurred. Furthermore, the decision-making process after an earthquake is elaborated. In addition, a numerical model is developed in 3Muri software for structural modeling. A non-linear static pushover analysis is performed, and possible failure mechanisms are examined. Furthermore, real-life damage is compared to the software results, and a conclusion process of the building’s usability is explained. In the end, the results obtained are analyzed and conclusions regarding the efficiency of the used software are drawn.

29 May 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
Tomislav KišičekTomislav Kišiček
Tomislav Kišiček
TRTvrtko Renić
Tvrtko Renić
DLDamir Lazarević
Damir Lazarević
IHIvan Hafner
Ivan Hafner
The amount of energy dissipated during an earthquake depends on the type of failure of the concrete element. Shear failure should be avoided because less energy is spent than that due to bending failure. Compression controlled failure is usually avoided by increasing the thickness of a wall. Considering that the current code largely decreases this strength, this becomes hard to achieve in practice. Because of that, the analysis described in this paper is made to determine the reason for a large strength reduction at high curvatures. Mechanisms contributing to compression controlled shear strength are analysed. Using Rankine’s strength theorem, section equilibrium, arch mechanism and bending moment-curvature diagrams, the influence of different parameters are observed and charted. The findings are compared to the existing procedures and a new, simple and safe analytical equation is derived. Compression controlled shear strength is mainly influenced by axial force, followed by the amount of longitudinal reinforcement and the achieved confinement. Results show that the value of strength reduces significantly with the increase of ductility and that some reduction exists even for lower levels of curvature. Current code provisions may lead to unsafe design, so designers should be careful when dealing with potentially critical walls.

30 December 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
IHIvan Hafner
Ivan Hafner
AVAnđelko Vlašić
Anđelko Vlašić
Tomislav KišičekTomislav Kišiček
Tomislav Kišiček
TRTvrtko Renić
Tvrtko Renić
Horizontal loads such as earthquake and wind are considered dominant loads for the design of tall buildings. One of the most efficient structural systems in this regard is the tube structural system. Even though such systems have a high resistance when it comes to horizontal loads, the shear lag effect that is characterized by an incomplete and uneven activation of vertical elements may cause a series of problems such as the deformation of internal panels and secondary structural elements, which cumulatively grow with the height of the building. In this paper, the shear lag effect in a typical tube structure will be observed and analyzed on a series of different numerical models. A parametric analysis will be conducted with a great number of variations in the structural elements and building layout, for the purpose of giving recommendations for an optimal design of a tube structural system.