Johanna Gleichauf

Ms. Johanna Gleichauf

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JGJohanna Gleichauf
Johanna Gleichauf
SHSven Herrmann
Sven Herrmann
LHLukas Hennemann
Lukas Hennemann
HKHannes Krauss
Hannes Krauss
JNJanina Nitschke
Janina Nitschke
AKAlexander Kölpin
Alexander Kölpin
This paper introduces an automatic non-contact monitoring method based on the synchronous evaluation of a 3D time-of-flight (ToF) camera and a microwave interferometric radar sensor for measuring the respiratory rate of neonates. The current monitoring on the Neonatal Intensive Care Unit (NICU) has several issues which can cause pressure marks, skin irritations and eczema. To minimize these risks, a non-contact system made up of a 3D time-of-flight camera and a microwave interferometric radar sensor is presented. The 3D time-of-flight camera delivers 3D point clouds which can be used to calculate the change in distance of the moving chest and from it the respiratory rate. The disadvantage of the ToF camera is that the heartbeat cannot be determined. The microwave interferometric radar sensor determines the change in displacement caused by the respiration and is even capable of measuring the small superimposed movements due to the heartbeat. The radar sensor is very sensitive towards movement artifacts due to, e.g., the baby moving its arms. To allow a robust vital parameter detection the data of both sensors was evaluated synchronously. In this publication, we focus on the first step: determining the respiratory rate. After all processing steps, the respiratory rate determined by the radar sensor was compared to the value received from the 3D time-of-flight camera. The method was validated against our gold standard: a self-developed neonatal simulation system which can simulate different breathing patterns. In this paper, we show that we are the first to determine the respiratory rate by evaluating the data of an interferometric microwave radar sensor and a ToF camera synchronously. Our system delivers very precise breaths per minute (BPM) values within the norm range of 20–60 BPM with a maximum difference of 3 BPM (for the ToF camera itself at 30 BPM in normal mode). Especially in lower respiratory rate regions, i.e., 5 and 10 BPM, the synchronous evaluation is required to compensate the drawbacks of the ToF camera. In the norm range, the ToF camera performs slightly better than the radar sensor.

18 April 2019
Verified
Book Chapter
Closed access
PDF file
JGJohanna Gleichauf
Johanna Gleichauf
JVJohannes Vollet
Johannes Vollet
CPChristian Pfitzner
Christian Pfitzner
PKPhilipp Koch
Philipp Koch
SMStefan May
Stefan May

19 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JGJohanna Gleichauf
Johanna Gleichauf
LHLukas Hennemann
Lukas Hennemann
Fabian Benedikt FahlbuschFabian Benedikt Fahlbusch
Fabian Benedikt Fahlbusch
OHOliver Hofmann
Oliver Hofmann
CNChristine Niebler
Christine Niebler
AKAlexander Kölpin
Alexander Kölpin
The monitoring of vital signs and increasing patient comfort are cornerstones of modern neonatal intensive care. Commonly used monitoring methods are based on skin contact which can cause irritations and discomfort in preterm neonates. Therefore, non-contact approaches are the subject of current research aiming to resolve this dichotomy. Robust neonatal face detection is essential for the reliable detection of heart rate, respiratory rate and body temperature. While solutions for adult face detection are established, the unique neonatal proportions require a tailored approach. Additionally, sufficient open-source data of neonates on the NICU is lacking. We set out to train neural networks with the thermal-RGB-fusion data of neonates. We propose a novel indirect fusion approach including the sensor fusion of a thermal and RGB camera based on a 3D time-of-flight (ToF) camera. Unlike other approaches, this method is tailored for close distances encountered in neonatal incubators. Two neural networks were used with the fusion data and compared to RGB and thermal networks. For the class “head” we reached average precision values of 0.9958 (RetinaNet) and 0.9455 (YOLOv3) for the fusion data. Compared with the literature, similar precision was achieved, but we are the first to train a neural network with fusion data of neonates. The advantage of this approach is in calculating the detection area directly from the fusion image for the RGB and thermal modality. This increases data efficiency by 66%. Our results will facilitate the future development of non-contact monitoring to further improve the standard of care for preterm neonates.

1 September 2024
Verified
Conference Paper
Open access
PRPhilipp Renner
Philipp Renner
JGJohanna Gleichauf
Johanna Gleichauf
SWSven Winkelmann
Sven Winkelmann
Monitoring drivers’ health is crucial for saving lives in emergencies and enabling in-car health applications. The state of the art in pulse monitoring is contact-based sensors which impair the driving experience and have to be applied manually before driving. This paper focuses on automated hyper parameter optimizing the Eulerian Video Magnification (EVM) algorithm, which detects heart rates through non-contact facial camera images, for use in driving scenarios. We conducted a user study where 21 participants performed a driving simulation while their heart rates were recorded by a wearable fitness tracker (serving as ground truth) and facial images with an RGB camera. Our findings indicate that, despite using the optuna library for hyper parameter tuning, the Eulerian Video Magnification algorithm is insufficient for accurate pulse detection in a driving simulator environment.

23 January 2024 in Scientific Data
Verified
Journal Article
Open access
PDF file
JGJohanna Gleichauf
Johanna Gleichauf
SHSven Herrmann
Sven Herrmann
CNChristine Niebler
Christine Niebler
AKAlexander Koelpin
Alexander Koelpin
In this paper we present an open-source Time-of-Flight and radar dataset of a neonatal thorax simulator for the development of respiratory rate detection algorithms. As it is very difficult to gain recordings of (preterm) neonates and there is hardly any open-source data available, we built our own neonatal thorax simulator which simulates the movement of the thorax due to respiration. We recorded Time-of-Flight (ToF) and radar data at different respiratory rates in a range of 5 to 80 breaths per minute (BPM) and with varying upstroke heights. As gold standard a laser micrometer was used. The open-source data can be used to test new algorithms for non-contact respiratory rate detection.