Thi Kim Dung Doan

Dr. Thi Kim Dung Doan

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2009 in Journal of Physics: Conference Series
Verified
Conference Paper
Closed access
TDThi Kim Dung Doan
Thi Kim Dung Doan
THTran Hoang Hai
Tran Hoang Hai
LPLe Hong Phuc
Le Hong Phuc
BLBui Duc Long
Bui Duc Long
LVLe Khanh Vinh
Le Khanh Vinh
PTPhan Nha Truc
Phan Nha Truc

4 March 2020 in Biomaterials Science
Verified
Journal Article
Closed access
PDF file
GYGil Yeroslavsky
Gil Yeroslavsky
MUMasakazu Umezawa
Masakazu Umezawa
KOKyohei Okubo
Kyohei Okubo
KNKarina Nigoghossian
Karina Nigoghossian
TDThi Kim Dung Doan
Thi Kim Dung Doan
KSKohei Soga
Kohei Soga
One of the most commonly used near infrared (NIR) dyes is indocyanine green (ICG), which has been extensively used for NIR bioimaging, photothermal and photodynamic therapy. However, upon excitation this dye can react with molecular oxygen to form singlet oxygen (SO), which can then cleave ICG to form non-fluorescent debris. In order to reduce the reaction between ICG and oxygen, we used energy transfer (ET) between the former and the NIR dye IR-1061. The two dyes were encapsulated in micelles composed of biocompatible poly(ethylene glycol)-block-poly(ε-caprolactone) (PCL–PEG). Micelles were characterized for their size using dynamic light scattering (DLS) and were found to measure about 35 nm in diameter. Fluorescence emission measurements were conducted to show that the stability of ICG against photodecomposition is increased. Moreover, this increased stability allows the encapsulated dye to generate more heat and for a longer time, compared to its free form. Studies with a SO indicator showed that as more IR-1061 is added to the micelles, less SO is produced. These results show how by changing the amount of added IR-1061 it is possible to tune the heat and SO generated by the system. Cell viability studies demonstrated that while particles were nontoxic under physiological conditions, upon 808 nm irradiation they become potent at eradicating MCF7 cancer cells. Moreover, it was demonstrated that both the increase of temperature and the creation of decomposition debris play a role in the cytotoxic efficacy of the micelles. Dye-loaded micelles that were injected to live mice showed bright fluorescence in the over 1000 nm NIR (OTN-NIR) region, allowing for visualization of blood vessels and internal organs. Most importantly, the encapsulated dyes remained stable for over 30 minutes, gradually accumulating in the liver and spleen. The presence of IR-1061 in addition to the heat-generating dye ICG allowed for simultaneous temperature modification and monitoring. We were able to assess the change in temperature by measuring the change in the fluorescence intensity of IR-1061 in the OTN-NIR region, a range with deep penetration of living tissues. These features illustrate the potential use of ICG/IR-1061 in PCL–PEG micelles as promising candidates for cancer treatment and diagnosis.

6 September 2016 in Nanomaterials
Verified
Journal Article
Open access
PDF file
TDThi Kim Dung Doan
Thi Kim Dung Doan
SFShoichiro Fukushima
Shoichiro Fukushima
TFTaichi Taichi Furukawa
Taichi Taichi Furukawa
HNHirohiko Niioka
Hirohiko Niioka
TSTakumi Sannomiya
Takumi Sannomiya
Jun MiyakeJun Miyake
Jun Miyake
Comprehensive imaging of a biological individual can be achieved by utilizing the variation in spatial resolution, the scale of cathodoluminescence (CL), and near-infrared (NIR), as favored by imaging probe Gd2O3 co-doped lanthanide nanophosphors (NPPs). A series of Gd2O3:Ln3+/Yb3+ (Ln3+: Tm3+, Ho3+, Er3+) NPPs with multispectral emission are prepared by the sol-gel method. The NPPs show a wide range of emissions spanning from the visible to the NIR region under 980 nm excitation. The dependence of the upconverting (UC)/downconverting (DC) emission intensity on the dopant ratio is investigated. The optimum ratios of dopants obtained for emissions in the NIR regions at 810 nm, 1200 nm, and 1530 nm are applied to produce nanoparticles by the homogeneous precipitation (HP) method. The nanoparticles produced from the HP method are used to investigate the dual NIR and CL imaging modalities. The results indicate the possibility of using Gd2O3 co-doped Ln3+/Yb3+ (Ln3+: Tm3+, Ho3+, Er3+) in correlation with NIR and CL imaging. The use of Gd2O3 promises an extension of the object dimension to the whole-body level by employing magnetic resonance imaging (MRI).

29 August 2020 in Structural Chemistry
Verified
Journal Article
Closed access
PDF file
BTBui Thi Phuong Thuy
Bui Thi Phuong Thuy
TMTran Thi Ai My
Tran Thi Ai My
NHNguyen Thi Thanh Hai
Nguyen Thi Thanh Hai
HLHuynh Thi Phuong Loan
Huynh Thi Phuong Loan
LHLe Trung Hieu
Le Trung Hieu
NNNhung Nguyen
Nhung Nguyen

24 June 2019 in Journal of Photopolymer Science and Technology
Verified
Journal Article
Open access
PDF file
GYGil Yeroslavsky
Gil Yeroslavsky
MUMasakazu Umezawa
Masakazu Umezawa
KOKyohei Okubo
Kyohei Okubo
KNKarina Nigoghossian
Karina Nigoghossian
TDThi Kim Dung Doan
Thi Kim Dung Doan
KSKohei Soga
Kohei Soga
Indocyanine Green (ICG) is one of the most common fluorescent dyes that emits in the near-infrared (NIR) region, with extensive use in the medical field. However, this dye is susceptible to photobleaching, thermal degradation and oxidation in acidic conditions. The major pathway by which ICG photobleaches involves sensitization to form singlet oxygen, which can react with the dye’s backbone, resulting in decomposition to non-fluorescent debris. In this paper we introduce the concept of using energy transfer (ET) for the protection of NIR dyes against photodecomposition. The dye IR-1061 was chosen as an ET pair due to its spectral overlap with ICG. First, it was shown that the presence of the former in solution reduced disintegration of the latter by absorbance and fluorescence spectroscopy. A singlet oxygen-reactive fluorescent indicator was employed to demonstrate that the production of this reactive species is also greatly reduced. This photoprotective effect was improved by encapsulation of the dyes in phospholipid-PEG micelles, which reduces the distance between them, thus enhancing the ET efficiency. The micelles were characterized for their optical properties and their size was determined to be about 10 nm with dynamic light scattering (DLS) techniques. The ET particles displayed greater fluorescence over 1000 nm compared to either dye encapsulated alone. The micelles proved to be superior than the free dye in terms of chemical, thermal and photo-stability. Moreover, the system demonstrated improved heating due to a greater photothermal effect compared to ICG dye in free or encapsulated form.

11 January 2022 in Biomaterials Science
Verified
Journal Article
Open access
PDF file
TDThi Kim Dung Doan
Thi Kim Dung Doan
MUMasakazu Umezawa
Masakazu Umezawa
KOKazunobu Ohnuki
Kazunobu Ohnuki
Karina NigoghossianKarina Nigoghossian
Karina Nigoghossian
KOKyohei Okubo
Kyohei Okubo
KSKohei Soga
Kohei Soga
Multimodal imaging can provide multidimensional information for understanding concealed microstructures or bioprocesses in biological objects. The combination of over–1000 nm near–infrared (OTN–NIR) fluorescence imaging and magnetic resonance (MR) imaging is promising in providing high sensitivity and structural information of lesions. This combination can be facilitated by the development of an imaging probe. The OTN–NIR and MR bimodal fluorescence probes reported to date primarily involve ceramic particles for fluorescence and MRI contrast enhancement effect. In this study, we designed a new bimodal OTN–NIR/MR imaging probe from organic components including an OTN–NIR fluorescent organic dye (IR–1061) encapsulated in the core of a micelle composed of poly(lactic–co–glycolic acid)–block–poly(ethylene glycol) copolymer (PLGA–PEG). For the MRI contrast, gadobutrol (Gd–DOTA) was introduced at the end of the PEG chain at various ratios. Subsequently, the OTN–NIR fluorescence and MR bimodal imaging probes of ca. 20 nm in size were successfully prepared and applied in mouse imaging. The probe exhibited absorption and emission in the OTN–NIR, and T1 contrast enhancement effects on MRI. Moreover, it demonstrated bright OTN–NIR fluorescence and MRI contrast enhancement to depict the blood veins and observe the organs in live mice. The imaging results revealed that the Gd–DOTA introduction ratio is of great importance for controlling the biological response of the probe without reducing the contrast enhancement effect.