Joanna Kozak

Prof. Joanna Kozak


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2015 in Talanta
Verified
Journal Article
Closed access
JKJoanna Kozak
Joanna Kozak
KLK. Latocha
K. Latocha
JKJ. Kochana
J. Kochana
MWM. Wieczorek
M. Wieczorek
PKP. Kościelniak
P. Kościelniak

1 February 2016 in Talanta
Verified
Journal Article
Closed access
JKJoanna Kozak
Joanna Kozak
JPJ. Paluch
J. Paluch
AWA. Węgrzecka
A. Węgrzecka
MKM. Kozak
M. Kozak
MWM. Wieczorek
M. Wieczorek
PKP. Kościelniak
P. Kościelniak

26 June 2021 in Molecules
Verified
Journal Article
Open access
PDF file
Paweł KościelniakPaweł Kościelniak
Paweł Kościelniak
PNPaweł Mateusz Nowak
Paweł Mateusz Nowak
JKJoanna Kozak
Joanna Kozak
MWMarcin Wieczorek
Marcin Wieczorek
An original strategy to evaluate analytical procedures is proposed and applied to verify if the flow-based methods, generally favorable in terms of green chemistry, are competitive when their evaluation also relies on other criteria. To this end, eight methods for the determination of zinc in waters, including four flow-based ones, were compared and the Red–Green–Blue (RGB) model was exploited. This model takes into account several features related to the general quality of an analytical method, namely, its analytical efficiency, compliance with the green analytical chemistry, as well as practical and economic usefulness. Amongst the investigated methods, the best was the flow-based spectrofluorimetric one, and a negative example was that one involving a flow module, ICP ionization and MS detection, which was very good in analytical terms, but worse in relation to other aspects, which significantly limits its overall potential. Good assessments were also noted for non-flow electrochemical methods, which attract attention with a high degree of balance of features and, therefore, high versatility. The original attempt to confront several worldwide accepted analytical strategies, although to some extent subjective and with limitations, provides interesting information and indications, establishing a novel direction towards the development and evaluation of analytical methods.

17 March 2011 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
PKPaweł Kościelniak
Paweł Kościelniak
JKJoanna Kozak
Joanna Kozak
MWMarcin Wieczorek
Marcin Wieczorek
A simple novel calibration approach called ‘the standard addition and indicative dilution method’ (SAIDM) is presented. It consists in addition of a standard solution to a sample and in successive dilution of this solution until the signal measured is equal to the signal produced by the undiluted sample. Due to the presence of the analyte in the sample environment, SAIDM can be effectively used when interference effects occur. It has been theoretically and experimentally proved that the method proposed is capable of overcoming strong interferences in flame atomic absorption spectrometry even in such cases where the standard addition method (SAM)—conventionally used for this purpose—fails. In addition, due to the possibility of avoiding the extrapolation process, it offers better precision than SAM. However, it has also been revealed that SAIDM cannot be considered as a versatile calibration approach because it leads to worse analytical results in terms of accuracy than SAM when the interference effect is of a multiplicative character.

18 April 2020 in Molecules
Verified
Journal Article
Open access
PDF file
JPJustyna Paluch
Justyna Paluch
JKJoanna Kozak
Joanna Kozak
MWMarcin Wieczorek
Marcin Wieczorek
Michal WozniakiewiczMichal Wozniakiewicz
Michal Wozniakiewicz
MGMałgorzata Gołąb
Małgorzata Gołąb
Paweł KościelniakPaweł Kościelniak
Paweł Kościelniak
A preconcentration module operated in flow mode and integrated with a sequential injection system with spectrophotometric detection was developed. Using the system, preconcentration was performed in continuous mode and was based on a membraneless evaporation process under diminished pressure. The parameters of the proposed system were optimized and the system was tested on the example of the spectrophotometric determination of Cr(III). The preconcentration effectiveness was determined using the signal enhancement factor. In the optimized conditions for Cr(III), it was possible to obtain the signal enhancement factors of around 10 (SD: 0.9, n = 4) and determine Cr(III) with precision and intermediate precision of 8.4 and 5.1% (CV), respectively. Depending on the initial sample volume, signal enhancement factor values of about 20 were achieved. Applicability of the developed preconcentration system was verified in combination with the capillary electrophoresis method with spectrophotometric detection on the example of determination of Zn in certified reference materials of drinking water and wastewater. Taking into account the enhancement factor of 10, a detection limit of 0.025 mg L−1 was obtained for Zn determination. Zn was determined with precision less than 6% (CV) and the results were consistent with the certified values.

27 March 2020 in Molecules
Verified
Journal Article
Open access
PDF file
JKJoanna Kozak
Joanna Kozak
JPJustyna Paluch
Justyna Paluch
MKMarek Kozak
Marek Kozak
MDMarta Duracz
Marta Duracz
MWMarcin Wieczorek
Marcin Wieczorek
Paweł KościelniakPaweł Kościelniak
Paweł Kościelniak
A novel approach to automated flow titration with spectrophotometric detection for the determination of Fe(III) is presented. The approach is based on the possibility of strict and simultaneous control of the flow rates of sample and titrant streams over time. It consists of creating different but precisely defined concentration gradients of titrant and analyte in each successively formed monosegments, and is based on using the calculated titrant dilution factor. The procedure was verified by complexometric titration of Fe(III) in the form of a complex with sulfosalicylic acid, using EDTA as a titrant. Fe(III) and Fe(II) (after oxidation to Fe(III) with the use of H2O2) were determined with good precision (CV lower than 1.7%, n = 6) and accuracy ( | RE | lower than 3.3%). The approach was applied to determine Fe(III) and Fe(II) in artesian water samples. Results of determinations were consistent with values obtained using the ICP–OES reference method. Using the procedure, it was possible to perform titration in 6 min for a wide range of analyte concentrations, using 2.4 mL of both sample and titrant.