22 September 2021 in Molecules
Verified
Journal Article
Open access
PDF file
MGMałgorzata Gołąb
Małgorzata Gołąb
MPMartyna Przybyłowska
Martyna Przybyłowska
PKPetr Kubáň
Petr Kubáň
PIPetra Itterheimová
Petra Itterheimová
Michal WozniakiewiczMichal Wozniakiewicz
Michal Wozniakiewicz
A fast method for the determination of tropane alkaloids, using a portable CE instrument with a capacitively coupled contactless conductivity detector (CE-C4D) was developed and validated for determination of atropine and scopolamine in seeds from Solanaceae family plants. Separation was obtained within 5 min, using an optimized background electrolyte consisting of 0.5 M acetic acid with 0.25% (w/v) β-CD. The limit of detection and quantification was 0.5 µg/mL and 1.5 µg/mL, respectively, for both atropine and scopolamine. The developed method was validated with the following parameters—precision (CV): 1.07–2.08%, accuracy of the assay (recovery, RE): 101.0–102.7% and matrix effect (ME): 92.99–94.23%. Moreover, the optimized CE-C4D method was applied to the analysis of plant extracts and pharmaceuticals, proving its applicability and accuracy.

18 April 2020 in Molecules
Verified
Journal Article
Open access
PDF file
JPJustyna Paluch
Justyna Paluch
JKJoanna Kozak
Joanna Kozak
MWMarcin Wieczorek
Marcin Wieczorek
Michal WozniakiewiczMichal Wozniakiewicz
Michal Wozniakiewicz
MGMałgorzata Gołąb
Małgorzata Gołąb
Paweł KościelniakPaweł Kościelniak
Paweł Kościelniak
A preconcentration module operated in flow mode and integrated with a sequential injection system with spectrophotometric detection was developed. Using the system, preconcentration was performed in continuous mode and was based on a membraneless evaporation process under diminished pressure. The parameters of the proposed system were optimized and the system was tested on the example of the spectrophotometric determination of Cr(III). The preconcentration effectiveness was determined using the signal enhancement factor. In the optimized conditions for Cr(III), it was possible to obtain the signal enhancement factors of around 10 (SD: 0.9, n = 4) and determine Cr(III) with precision and intermediate precision of 8.4 and 5.1% (CV), respectively. Depending on the initial sample volume, signal enhancement factor values of about 20 were achieved. Applicability of the developed preconcentration system was verified in combination with the capillary electrophoresis method with spectrophotometric detection on the example of determination of Zn in certified reference materials of drinking water and wastewater. Taking into account the enhancement factor of 10, a detection limit of 0.025 mg L−1 was obtained for Zn determination. Zn was determined with precision less than 6% (CV) and the results were consistent with the certified values.

6 August 2022 in Molecules
Verified
Journal Article
Open access
PDF file
PNPaweł Mateusz Nowak
Paweł Mateusz Nowak
MKMaria Klag
Maria Klag
GKGabriela Kózka
Gabriela Kózka
MGMałgorzata Gołąb
Małgorzata Gołąb
Michal WozniakiewiczMichal Wozniakiewicz
Michal Wozniakiewicz
This article presents the first successful application of a capillary electrophoresis-microscale thermophoresis tandem technique (CE-MST) for determining the values of equilibrium constant, realized by connecting online the CE and MST instruments using a fused-silica capillary. The acid-base dissociation of fluorescein isothiocyanate, expressed by the acidity constant value (pKa), was used as a model. The measurement procedure consisted of introducing a mixture containing the analyte and a deliberately added interferent into the CE capillary, electrophoretic separation of the analyte from the interferent, the detection of the analyte with a CE-integrated detector, detection with a MST detector, and then stopping the flow temporarily by turning off the voltage source to conduct the thermophoretic measurement. The analysis of migration times, peak areas and MST responses obtained concurrently for the same sample allowed us to determine the pKa value using three independent methods integrated within one instrumentation. The analyte was effectively separated from the interferent, and the acidity values turned out to be consistent with each other. An attempt was also made to replace the standard commercial CE instrument with a home-made portable CE setup. As a result, the similar pKa value was obtained, at the same time proving the possibility of increasing cost efficiency and reducing energy consumption. Overall, the CE-MST technique has a number of limitations, but its unique analytical capabilities may be beneficial for some applications, especially when sample separation is needed prior to the thermophoretic measurement.

16 October 2021 in Molecules
Verified
Journal Article
Open access
PDF file
MGMałgorzata Gołąb
Małgorzata Gołąb
Michal WozniakiewiczMichal Wozniakiewicz
Michal Wozniakiewicz
PNPaweł Mateusz Nowak
Paweł Mateusz Nowak
Paweł KościelniakPaweł Kościelniak
Paweł Kościelniak
In this paper, a novel procedure for preparing calibration solutions for capillary electrophoresis (CE)-based quantitative analysis is proposed. Our approach, named the automated hydrodynamically mediated technique (AHMT), uses a capillary and a pressure system to deliver the expected amount of working solution and diluent directly to a sample vial. As a result, calibration solutions are prepared automatically inside the CE instrument, without any or with minimal manual operation. Two different modes were tested: forward and reverse, differing in the direction of hydrodynamic flow. The calibration curves obtained for a model mixture of analytes using AHMT were thorough compared to the standard procedure based on manual pipetting. The results were consistent, though the volume of obtained calibration solutions and the potential risk of random errors were significantly minimized by AHMT. Its effectiveness was further enhanced by the application of SCIEX® nanoVials, reducing the actual volume of calibration solutions down to 10 μL.