kyungho kim

kyungho kim


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2006
Verified
Conference Paper
Closed access
JLJeong-Whan Lee
Jeong-Whan Lee
KLKang-Hwi Lee
Kang-Hwi Lee
KKKyeong-Seop Kim
Kyeong-Seop Kim
DKDong-Jun Kim
Dong-Jun Kim
KKkyungho kim
kyungho kim
The design of an intelligent toothbrush, capable of monitoring brushing motion, orientation through the grip axis, during toothbrushing is described. Inappropriate tooth-brushing styles, even in adults, sometimes cause dental problems, cavities, gingivitis, etc. This smart system provides user to monitor his or her brushing pattern using accelerometer and magnetic sensors for evaluation of toothbrushing style. Directional information of toothbrush with respect to the earth's magnetic field and activity data were measured by a miniaturized low-power micro-controller, MSP430 and transmitted to personal computer by 2.4 GHz radio transmitter, nRF2401. A personal computer provides an on-line display of activity and orientation measurements during toothbrushing. The signal trace is then analyzed to extract clinically relevant information. This preliminary study showed that the proposed monitoring system was conceived to aid dental care personnel in patient education and instruction in oral hygiene regarding brushing style

1 August 2007 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
KLKang-Hwi Lee
Kang-Hwi Lee
JLJeong-Whan Lee
Jeong-Whan Lee
KKKyeong-Seop Kim
Kyeong-Seop Kim
DKDong-Jun Kim
Dong-Jun Kim
KKkyungho kim
kyungho kim
BLByungchae Lee
Byungchae Lee
The concept of intelligent toothbrush, capable of monitoring brushing motion, orientation through the grip axis, during toothbrushing was suggested in our previous study. In this study, we describe a tooth brushing pattern classification algorithm using three-axis accelerometer and three-axis magnetic sensor. We have found that inappropriate tooth brushing pattern showed specific moving patterns. In order to trace the position and orientation of toothbrush in a mouth, we need to know absolute coordinate information of toothbrush. By applying tilt-compensated azimuth (heading) calculation algorithm, which is generally used in small telematics devices, we could find the inclination and orientation information of toothbrush. To assess the feasibility of the proposed algorithm, 8 brushing patterns were preformed by 6 individual healthy subjects. The proposed algorithm showed the detection ratio of 98%. This study showed that the proposed monitoring system was conceived to aid dental care personnel in patient education and instruction in oral hygiene regarding brushing style.

1 January 2006
Verified
Conference Paper
Closed access
JLJeong-Whan Lee
Jeong-Whan Lee
LHLee-Yon Hong
Lee-Yon Hong
JJJaehoon Jun
Jaehoon Jun
KLKang-Hwi Lee
Kang-Hwi Lee
KKKyeong-Seop Kim
Kyeong-Seop Kim
KKkyungho kim
kyungho kim
Medical practioners usually measure dorsiflection of the human joint angle for medical assessment purpose. In order to measure the joint angle, a more or less standard mechanical or electro-mechanical goniometer is used. But mechanical construction has many problems. This research is originated from the lack of user-friendly, versatile and not expensive apparatus which are commercially available. In this paper, we present new design concepts of goniometer utilizing the light refraction characteristics of optical fiber in order to measure angular displacement of the human joints. In order to form an asymmetrical beam profile at the end of fiber tips, we cut the end of fiber tip at an angle of 35 degrees. Phototransistor is used to measure beam intensity as a function of optical fiber angle with respect to optical axis of fiber. Thus the sensed signal represented an indirect measure of curvature angle. The result showed that asymmetrical beam profile provide wider linear relationship than symmetrical one. Eventually, overall performance of the proposed sensor is quite suitable for measurement of the human joint angle

1 November 2015 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
KHKap-Soo Han
Kap-Soo Han
HNHyun Do Nam
Hyun Do Nam
KKkyungho kim
kyungho kim
Core muscle Strengthening Effect During Spine Stabilization Exercise Core muscle strengthening;Spine stabilization exercise device;Whole body tilt;Musculoskeletal model; Core spinal muscles are related to trunk stability and assume the main role of stabilizing the spine during daily activities; strengthening of core muscles around the spine can therefore reduce the chance of back pain. The objective of the study was to investigate the effect of core muscle strengthening in the spine during spine stabilization exercise using a whole body tilt device. To achieve this, a validated musculoskeletal (MS) model of the whole body was used to replicate the input motion from the whole body tilting exercise. An inverse dynamics analysis was executed to estimate spine loads and muscle forces depending on the tilting angles of the exercise device. The activation of long and superficial back muscles such as the erector spinae (iliocostalis and longissimus) were mainly affected by the forward direction (-40°) of the tilt, while the front muscles (psoas major, quadratus lumborum, and external and internal obliques) were mainly affected by the backward tilting direction (40°). Deep muscles such as the multifidi and short muscles were activated in most directions of the rotation and tilt. The backward directions of the tilt using this device could be carefully applied for the elderly and for rehabilitation patients who are expected to have less muscle strength. In this study, it was shown that the spine stabilization exercise device can provide considerable muscle exercise effect.

1 February 2007
Verified
Conference Paper
Closed access
JIJeong-Don Ihm
Jeong-Don Ihm
SBSeung-Jun Bae
Seung-Jun Bae
KPKwang Il Park
Kwang Il Park
HSHo-Young Song
Ho-Young Song
WLWoo Jin Lee
Woo Jin Lee
SCSoo-In Cho
Soo-In Cho
A 4Gb/s/pin 32b parallel 512Mb GDDR4 SDRAM is implemented in an 80nm DRAM process. It employs a data-bus inversion coding scheme with an analog majority voter insensitive to mismatch, which reduces peak-to-peak jitter by 21 ps and voltage fluctuation by 68mV. A dual duty-cycle corrector is proposed to average duty error, and tuning is added to the auto-calibration of driver and termination impedance.

19 January 2021 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
CYChulseung Yang
Chulseung Yang
Giwon KuGiwon Ku
Giwon Ku
JLJeong Gi Lee
Jeong Gi Lee
KKkyungho kim
kyungho kim