Jaehoon Jun

Prof. Jaehoon Jun

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JJJaehoon Jun
Jaehoon Jun
JRJooyeol Rhee
Jooyeol Rhee
SKSangwoo Kim
Sangwoo Kim
SKSuhwan Kim
Suhwan Kim
CRCyuyeol Rhee
Cyuyeol Rhee
This paper presents a switched capacitor interface circuit for a monolithic three-axis capacitive micro-electro-mechanical system (MEMS) accelerometer. The MEMS sensor and the interface circuit of our system-in-package-type MEMS accelerometer are 3-D stacked to optimize integration density with a small package footprint. The proposed fully integrated interface circuit includes a capacitance-to-voltage converter followed by a Δ Σ analog-to-digital converter (ADC). To optimize system power and area, the programmable-gain functionality is embedded to the second-order Δ Σ ADC without any stability degradation. The offset and 1/f noise of the fully differential interface circuit are mitigated by a correlated double sampling technique. The rest of the low-frequency error from system mismatch is also suppressed by calibration using fine metal-oxide-semiconductor capacitor array. The measurement results of our MEMS accelerometer show a 13.7-b maximum effective resolution with the 197-μg/√Hz noise floor in a conversion time of 1 ms with a maximum nonlinearity of 1.09%. Implemented in a standard 0.18-μm CMOS technology, the fabricated chip consumes only 247-μA current from a 3.3-V supply, and 37-μA current from a 1.8-V supply.

27 August 2019 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
JJJaehoon Jun
Jaehoon Jun
SPSoungchul Park
Soungchul Park
JKJunho Kang
Junho Kang
SKSuhwan Kim
Suhwan Kim

30 May 2012 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Closed access
PDF file
JKJiwon Kim
Jiwon Kim
YKYuri Kwon
Yuri Kwon
GEGwang-Moon Eom
Gwang-Moon Eom
JJJaehoon Jun
Jaehoon Jun
JLJeong-Whan Lee
Jeong-Whan Lee
GTGye-Rae Tack
Gye-Rae Tack

18 August 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JJJaehoon Jun
Jaehoon Jun
SSSangmin Shin
Sangmin Shin
MKMinsung Kim
Minsung Kim
YAYongjoon Ahn
Yongjoon Ahn
SKSuhwan Kim
Suhwan Kim
This paper describes a high accurate humidity sensing system. The humidity sensor and the interface circuit of our system-in-package (SiP) are 3-D stacked to optimize integration density with small foot print. A single reconfigurable ADC is utilized for both 3-D stacked humidity and on-chip temperature sensors. An incremental ΔΣ ADC with a reconfigurable ΔΣ modulator is employed with dual input stages. With the combination of chopping, correlated double sampling (CDS), dynamic element matching (DEM), and system-level chopping techniques, high accuracy sensing system is achieved. The interface circuit, implemented in a standard CMOS 0.18 μm CMOS technology, occupies an area of 1.24 mm2. The SiP sensing system dissipates only 146.5 μA and 25 μA from 3.3 V supply and 1.8 V supply, respectively. Its humidity inaccuracy is 0.15 %RH with a resolution of 0.012 %RH, while a temperature inaccuracy is 0.44 °C (3σ) with a resolution of 0.015 °C.

1 January 2006
Verified
Conference Paper
Closed access
JLJeong-Whan Lee
Jeong-Whan Lee
LHLee-Yon Hong
Lee-Yon Hong
JJJaehoon Jun
Jaehoon Jun
KLKang-Hwi Lee
Kang-Hwi Lee
KKKyeong-Seop Kim
Kyeong-Seop Kim
KKkyungho kim
kyungho kim
Medical practioners usually measure dorsiflection of the human joint angle for medical assessment purpose. In order to measure the joint angle, a more or less standard mechanical or electro-mechanical goniometer is used. But mechanical construction has many problems. This research is originated from the lack of user-friendly, versatile and not expensive apparatus which are commercially available. In this paper, we present new design concepts of goniometer utilizing the light refraction characteristics of optical fiber in order to measure angular displacement of the human joints. In order to form an asymmetrical beam profile at the end of fiber tips, we cut the end of fiber tip at an angle of 35 degrees. Phototransistor is used to measure beam intensity as a function of optical fiber angle with respect to optical axis of fiber. Thus the sensed signal represented an indirect measure of curvature angle. The result showed that asymmetrical beam profile provide wider linear relationship than symmetrical one. Eventually, overall performance of the proposed sensor is quite suitable for measurement of the human joint angle

1 February 2018
Verified
Conference Paper
Closed access
JJJaehoon Jun
Jaehoon Jun
JRJooyeol Rhee
Jooyeol Rhee
MKMinsung Kim
Minsung Kim
JKJunho Kang
Junho Kang
SKSuhwan Kim
Suhwan Kim
CRCyuyeol Rhee
Cyuyeol Rhee
High-resolution read-out integrated circuits (ROICs) are often used in DC measurement systems such as bridge transducers. Since these typically output small-amplitude signals with a bandwidth of a few hertz, a highly linear gain ROIC is required with a resolution above 20b [1,2]. In previous work, high-precision instrumentation amplifiers (IAs) followed by analog-to-digital converters (ADCs) were reported [1-4]. However, IA topologies based on switched-capacitor (SC) or multiple operational amplifiers (opamps) suffer from a poor power-noise tradeoff due to noise folding [2], or the number of amplifiers [3], respectively. Current-feedback IAs (CFIAs) are more power-efficient, but require highly linear feedback resistors [4,5]. This drawback can be addressed by capacitively-coupled IAs (CCIAs), which are even more power efficient [1].