Arian Marcelino-Argemi

Mr. Arian Marcelino-Argemi

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2026 in Regenerative Therapy
Verified
Journal Article
Open access
MVMarta Martín - Vega
Marta Martín - Vega
ACAlvaro Gomez Carrion
Alvaro Gomez Carrion
IZIgnacio Zaragoza-García
Ignacio Zaragoza-García
IOIsmael Ortuño-Soriano
Ismael Ortuño-Soriano
AMArian Marcelino-Argemi
Arian Marcelino-Argemi
Ruben Sanchez-GomezRuben Sanchez-Gomez
Ruben Sanchez-Gomez
Osteoarthritis is an increasingly prevalent condition with limited conservative treatments. Platelet-rich plasma (PRP) therapy has gained attention, but its efficacy may depend on the type used. In particular, leukocyte-rich (LR-PRP) and leukocyte-poor (LP-PRP) formulations may influence outcomes, yet direct comparisons are limited. a systematic literature search and analysis of clinical trials, through PubMed database, were conducted to evaluate the effect of leukocyte – rich and leukocyte – poor platelet rich plasma in the treatment of osteoarthritis. 11 articles were analyzed individually, including both in vivo and in vitro studies, to examine the effect of leukocytes in PRP. This review highlights that current evidence is insufficient to determine whether adding leukocytes to PRP provides a clinical benefit in the treatment of osteoarthritis. Overall, results generally show no significant differences between LR-PRP and LP-PRP, suggesting that both may be effective. Although leukocytes were initially thought to induce inflammation, there is no conclusive evidence that local reactions are directly caused by them. Given the limitations of existing studies, further research is required to clarify the role of leukocytes in PRP therapy.

7 April 2026 in Life
Verified
Journal Article
Open access
PDF file
AMArian Marcelino-Argemi
Arian Marcelino-Argemi
DAN IULIAN ALEXEDAN IULIAN ALEXE
DAN IULIAN ALEXE
IOIsmael Ortuño-Soriano
Ismael Ortuño-Soriano
IZIgnacio Zaragoza-García
Ignacio Zaragoza-García
ÁSÁlvaro Saura Sempere
Álvaro Saura Sempere
Ruben Sanchez-GomezRuben Sanchez-Gomez
Ruben Sanchez-Gomez
Background/Objectives: Several methods have been proposed to assess lower limb-length discrepancies; however, none have demonstrated sufficient reliability and validity for diagnosing anatomical discrepancies (DA). Objectives: This study primarily aims to evaluate the accuracy of two traditional tests—the Modified Iliac Crests Palpation and Pelvimeter with Blocks test (ICPBL) and plantar pressure analysis—by comparing them with the gold standard telemetry (TE) method for diagnosing DA. The secondary objective is to assess the intra-rater reliability of these two tests and determine their potential applicability in clinical settings. Methods: Thirty subjects between the ages of 20 and 80 were enrolled in the present prospective, cross-sectional diagnostic accuracy pilot study; thirteen with a positive TE for DA of more than 3 mm were classified into the group with the condition DA, and 17 were classified into the group without the condition DA. Pelvic tilting and plantar pressures were evaluated. Results: The TE revealed a difference of 8.09 ± 3.24 mm between the short and long limbs, while subjects without DA had only a 0.41 mm difference (p < 0.001). Similarly, the Modified ICPBL test showed a 4.38 ± 2.10 mm difference in subjects with DA, compared to 0.51 ± 0.53 mm in those without DA (p < 0.001). Additionally, plantar pressure measurements supported these findings, with a difference of 5.17 ± 3.28 kg/cm2 between the short and long limbs in subjects with DA, versus 2.28 ± 1.77 kg/cm2 in subjects without DA (p < 0.05). The area under the receiver operating characteristic (ROC) curve was 0.783 (95% CI: 0.456–0.877) for plantar pressures and 1.000 (95% CI: 0.742–0.942) for the Modified ICPBL test. Conclusions: The Modified ICPBL and plantar pressure tests demonstrated high diagnostic accuracy within the sample studied, suggesting they are useful tools for supporting the diagnosis of DA. In this pilot study, the Modified ICPBL showed very high discriminative ability, while plantar pressure testing demonstrated moderate sensitivity. Both methods may serve as preliminary practical alternatives to telemetry TE, potentially reducing X-ray exposure; however, these results should be interpreted with caution due to the limited sample size and the specific clinical setting of this study.