Ruben Sanchez-Gomez

Prof. Dr. Ruben Sanchez-Gomez

Universidad Complutense de Madrid, Avda. Complutense, 28040 Madrid (Spain)
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2020 in Foot & Ankle International
Verified
Journal Article
Closed access
PDF file
Ruben Sanchez-GomezRuben Sanchez-Gomez
Ruben Sanchez-Gomez
RVRicardo Becerro de Bengoa Vallejo
Ricardo Becerro de Bengoa Vallejo
MIMarta Elena Losa Iglesias
Marta Elena Losa Iglesias
César Calvo LoboCésar Calvo Lobo
César Calvo Lobo
Emmanuel Navarro FloresEmmanuel Navarro Flores
Emmanuel Navarro Flores
Daniel López-LópezDaniel López-López
Daniel López-López
Functional hallux limitus (FHL) refers to dorsiflexion hallux mobility limitation when the first metatarsal head is under loading conditions but not in the unloaded state. The goal of the study was to evaluate 3 common manual tests (Buell, Dananberg, and Jack tests) for assessing first metatarsophalangeal joint (MPJ) mobility and determining the normal values needed to detect FHL, and clarify the signs and symptoms associated with this pathology. Forty-four subjects were included in this reliability study. Subjects were divided into healthy control (non-FHL) and FHL groups according to the Buell first MPJ limitation values in addition to signs and symptoms derived from the literature. In both groups, we measured the mobility in the Buell, Dananberg, and Jack tests using a goniometer; their intraclass correlation coefficients (ICCs), sensitivities, and specificity indexes were also calculated. All techniques showed high reliability across measurement trials with ICCs ranging from 0.928 to 0.999. The optimal mobility grades for predicting FHL were 68.6 ± 3.7 degrees, 21 ± 5.9 degrees, and 25.5 ± 6.5 degrees (mean±SD) (P < .05) for the Buell, Dananberg, and Jack tests, respectively. Normal and limited mobility values were established for assessing FHL using each technique. The sensitivity and specificity data were perfect for the Dananberg and Jack tests, thus identifying these tests as specific and valid tools for use in FHL diagnosis. Pinch callus was the sign most associated with FHL. Level II, comparative series.

1 December 2018 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
ARAndrea Roca-Dols
Andrea Roca-Dols
MIMarta Elena Losa Iglesias
Marta Elena Losa Iglesias
Ruben Sanchez-GomezRuben Sanchez-Gomez
Ruben Sanchez-Gomez
RVRicardo Becerro de Bengoa Vallejo
Ricardo Becerro de Bengoa Vallejo
Daniel López-LópezDaniel López-López
Daniel López-López
César Calvo LoboCésar Calvo Lobo
César Calvo Lobo

4 March 2024 in Behavioral Sciences
Verified
Journal Article
Open access
PDF file
SASahreen Anwar
Sahreen Anwar
JZJunaid Zahid
Junaid Zahid
Cristina Ioana AlexeCristina Ioana Alexe
Cristina Ioana Alexe
AGAbdullah Ghazi
Abdullah Ghazi
GMGabriel Mares
Gabriel Mares
Qais GasibatQais Gasibat
Qais Gasibat
The purpose of this randomized controlled trial was to evaluate the effectiveness of the Myofascial Release Technique (MRT) along with Cognitive Behavioral Therapy (CBT) on pain, craniovertebral angle (CVA), and neck disability in university students with chronic neck pain and forward head posture. A total of sixty-six eligible participants with chronic neck pain and forward head posture were randomized into the Myofascial Release Therapy (MRT) group (n = 33) and MRT and Cognitive Behavior Therapy (CBT) group (n = 33). Clinical outcomes included neck pain measured using the numerical pain rating scale, neck disability measured through the neck disability index, and forward head posture measured through the cranial vertebral angle. The outcomes were assessed at baseline and the four and eight weeks after the intervention. Both groups showed significant improvement in pain intensity, CVA, and neck disability after the intervention. However, the CBT group demonstrated greater improvements than the MRT group. The difference in outcomes between the groups was statistically significant. Myofascial Release Therapy combined with CBT is an effective treatment method for patients with chronic neck pain and forward head posture.

2 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Carlos Romero-MoralesCarlos Romero-Morales
Carlos Romero-Morales
PMPedro Javier Martín-Llantino
Pedro Javier Martín-Llantino
César Calvo LoboCésar Calvo Lobo
César Calvo Lobo
Daniel López-LópezDaniel López-López
Daniel López-López
Ruben Sanchez-GomezRuben Sanchez-Gomez
Ruben Sanchez-Gomez
DRDavid Rodriguez
David Rodriguez
Purpose: The goal of the present study was to assess, by ultrasound imaging (USI), the thickness of the plantar fascia (PF) at the insertion of the calcaneus, mid and forefoot fascial locations, and the calcaneal fat pad (CFP) in patients with Achilles tendinopathy (AT). Methods: An observational case-control study. A total sample of 143 individuals from 18 to 55 years was evaluated by USI in the study. The sample was divided into two groups: A group composed of the chronic non-insertional AT (n = 71) and B group comprised by healthy subjects (n = 72). The PF thicknesses at insertion on the calcaneus, midfoot, rearfoot and CFP were evaluated by USI. Results: the CFP and PF at the calcaneus thickness showed statistically significant differences (P < 0.01) with a decrease for the tendinopathy group with respect to the control group. For the PF midfoot and forefoot thickness, no significant differences (P > 0.05) were observed between groups. Conclusion: The thickness of the PF at the insertion and the CPF is reduced in patients with AT measured by USI.

20 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SSSahar Safarloo
Sahar Safarloo
ANArántzazu Núñez-Cascajero
Arántzazu Núñez-Cascajero
Ruben Sanchez-GomezRuben Sanchez-Gomez
Ruben Sanchez-Gomez
CVCarmen Vazquez
Carmen Vazquez
The proper measurement of plantar pressure during gait is critical for the clinical diagnosis of foot problems. Force platforms and wearable devices have been developed to study gait patterns during walking or running. However, these devices are often expensive, cumbersome, or have boundary constraints that limit the participant’s motions. Recent advancements in the quality of plastic optical fiber (POF) have made it possible to manufacture a low-cost bend sensor with a novel design for use in plantar pressure monitoring. An intensity-based POF bend sensor is not only lightweight, non-invasive, and easy to construct, but it also produces a signal that requires almost no processing. In this work, we have designed, fabricated, and characterized a novel intensity POF sensor to detect the force applied by the human foot and measure the gait pattern. The sensors were put through a series of dynamic and static tests to determine their measurement range, sensitivity, and linearity, and their response was compared to that of two different commercial force sensors, including piezo resistive sensors and a clinical force platform. The results suggest that this novel POF bend sensor can be used in a wide range of applications, given its low cost and non-invasive nature. Feedback walking monitoring for ulcer prevention or sports performance could be just one of those applications.

6 May 2023 in Healthcare
Verified
Journal Article
Open access
PDF file
Julio Alberto Mateos ArroyoJulio Alberto Mateos Arroyo
Julio Alberto Mateos Arroyo
IZIgnacio Zaragoza-García
Ignacio Zaragoza-García
Ruben Sanchez-GomezRuben Sanchez-Gomez
Ruben Sanchez-Gomez
PPPaloma Posada-Moreno
Paloma Posada-Moreno
IOIsmael Ortuño-Soriano
Ismael Ortuño-Soriano
In order to predict the high mortality due to COVID-19, simple, useful and remote instruments are required. To assess the validity of the baseline Barthel Index score as a predictor of in-hospital mortality among COVID-19 patients, a validation study of a clinical prediction tool in a cohort of patients with COVID-19 was conducted. The primary variable was mortality and the Barthel Index was the main explanatory variable. Demographic, clinical and laboratory variables were collected. Other mortality predictor scores were also assessed: Pneumonia Severity Index, CURB-65 and A-DROP. The Receiver Operating Characteristic Area under the Curve (ROC AUC), sensitivity and specificity were calculated for both the Barthel Index and the other predictor scores. An analysis of the association between the main variables was conducted, adjusting by means of three multivariate models. Three hundred and twelve patients were studied. Mortality was 16.4%. A mortality Odds Ratio (OR) of 5.95 was associated with patients with a Barthel Index ≤ 90. The model number 3 was developed to predict in-hospital mortality before COVID-19 infection occurs. It exhibits an OR of 3.44, a ROC AUC of 0.792, a sensitivity of 74.5% and a specificity of 73.9%. The Baseline Barthel Index proved useful in our population as a predictor of in-hospital mortality due to COVID-19.