A ducted photovoltaic façade (DPV) unit was studied using experimental prototype and simulated in a full scale computational fluid dynamics (CFD) model. The study comes in two parts; this is Part I, as detailed in the title above, and Part II is titled “A Ducted Photovoltaic Façade Unit with Buoyancy Cooling: Part II CFD Simulation”. The process adopted in the experimental study is replicated in the simulation part. The aim was to optimize the duct width behind the solar cells to allow for a maximum buoyancy-driven cooling for the cells during operation. Duct widths from 5 to 50 cm were tested in a prototype. A duct width of 45 cm had the maximum calculated heat removed from the duct; however, the lowest cell-operating temperature was reported for duct width of 50 cm. It was found that ΔT between ducts’ inlets and outlets range from 5.47 °C to 12.32 °C for duct widths of 5–50 cm, respectively. The ducted system enhanced module efficiency by 12.69% by reducing photovoltaic (PV) temperature by 27 °C from 100 °C to 73 °C. The maximum measured heat recovered from the ducted PV system was 422 W. This is 48.98% from the incident radiation in the test. The total sum of heat recovered and power enhanced by the ducted system was 61.67%.
A ducted photovoltaic façade (DPV) unit was simulated using computational fluid dynamics (CFD). This is Part II of the study, which is a repetition of Part I—a previous experimental study of the ducted photovoltaic unit with buoyancy cooling. The aim of this study is to optimize the duct width behind the solar cells to allow for the cells to achieve maximum buoyancy-driven cooling during operation. Duct widths from 5 to 50 cm were simulated. A duct width of 40 cm allowed for the maximum calculated heat to be removed from the duct; however, the lowest cell-operating temperature was reported for a duct width of 50 cm. The results showed that the change in temperature (ΔT) between the ducts’ inlets and outlets ranged from 8.10 to 19.32 °C. The ducted system enhanced module efficiency by 12.69% by reducing the photovoltaic façade (PV) temperature by 27 °C from 100 to 73 °C, as opposed to the increased temperatures that have been reported when fixing the PV directly onto the building fabric. The maximum simulated heat recovered from the ducted PV system was 529 W. This was 47.98% of the incident radiation in the test. The total summation of heat recovered and the power enhanced by the ducted system was 61.67%. The nature of airflow inside the duct was explored and visualized by reference to the Grashof number (Gr) and CFD simulations, respectively.
This paper presents an approach towards enhanced building-integrated wind harnessing. It uses building forms and profiles to trigger continuous air entrainment to power turbines. Computational fluid dynamics is used for evaluating, testing, and optimizing proposed designs. Wind separation around buildings is modeled alongside an investigation into the parameters of a wing-profile to accelerate wind. Computational fluid dynamics provides a good tool for modeling, designing, and optimizing aerofoil shapes. The main parameters affecting the wing’s wind harnessing capabilities are the distance between the wing and the building and the angle of attack of the wing. The aerofoil can magnify wind velocity by a factor ranging from 0.53 to 3.5; that is, from just below Betz limit to over six times the limit, depending on incident velocities. Practical applications: The approach presented in this paper can be implemented directly into optimization of new designs of buildings to integrate wind energy harnessing. Furthermore, new proposed wing shapes or profiles can be investigated by the same procedure presented in this study. Computational fluid dynamics investigations to building-mounted wind technologies, such as the ones presented here, are becoming increasingly adopted in the design process in practice, in university courses and future research.
A ducted photovoltaic façade (DPV) unit Studied using experimental Prototype and simulated in a full scale Computational Fluid Dynamics CFD Model. The Study comes in two parts; This is Part I with the title detailed above and Part II titled ‘A Ducted Photovoltaic Façade Unit with Buoyancy Cooling: Part II CFD Simulation’.. The process adopted in the experimental study is replicated in the simulation Part. The aim was to optimize the duct width behind the solar cells to allow for maximum buoyancy-driven cooling for the cells during operation. Duct widths from 5 to 50 cm were tested in a Proto-type. A duct width of 45 cm had the maximum calculated heat removed from the duct; however, the lowest cell-operating temperature was reported for duct width of 50 cm. It was found that the DT between ducts' inlets and outlets range from 5.47 °C to 12.32 °C for duct widths of 5–50 cm, respectively. The ducted system enhanced module efficiency by 12.69% by reducing PV temperature by 27 °C from 100°C to 73 °C. The maximum calculated heat recovered from the ducted PV system is 422 W. This is 47.98% from the incident radiation in the test. Total summation of heat recovered and power enhanced by the ducted system is 61.67%.