Abel Plaza-Florido

Dr. Abel Plaza-Florido

Pediatrics, University of California, Irvine, Irvine, California, USA
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JAJuan M. A. Alcantara
Juan M. A. Alcantara
APAbel Plaza-Florido
Abel Plaza-Florido
Francisco J. Amaro-GaheteFrancisco J. Amaro-Gahete
Francisco J. Amaro-Gahete
FAFrancisco M. Acosta
Francisco M. Acosta
JMJairo H Migueles
Jairo H Migueles
Borja Martínez-TéllezBorja Martínez-Téllez
Borja Martínez-Téllez
Heart rate variability (HRV) is a non-invasive indicator of autonomic nervous system function. HRV recordings show artefacts due to technical and/or biological issues. The Kubios software is one of the most used software to process HRV recordings, offering different levels of threshold-based artefact correction (i.e., Kubios filters). The aim of the study was to analyze the impact of different Kubios filters on the quantification of HRV derived parameters from short-term recordings in three independent human cohorts. A total of 312 participants were included: 107 children with overweight/obesity (10.0 ± 1.1 years, 58% men), 132 young adults (22.2 ± 2.2 years, 33% men) and 73 middle-aged adults (53.6 ± 5.2 years, 48% men). HRV was assessed using a heart rate monitor during 10–15 min, and the Kubios software was used for HRV data processing using all the Kubios filters available (i.e., 6). Repeated-measures analysis of variance indicated significant differences in HRV derived parameters in the time-domain (all p < 0.001) across the Kubios filters in all cohorts, moreover similar results were observed in the frequency-domain. When comparing two extreme Kubios filters, these statistical differences could be clinically relevant, e.g. more than 10 ms in the standard deviation of all normal R-R intervals (SDNN). In conclusion, the results of the present study suggest that the application of different Kubios filters had a significant impact on HRV derived parameters obtained from short-term recordings in both time and frequency-domains.

3 April 2019 in Obesity Reviews
Verified
Journal Article
Closed access
PDF file
PMPablo Molina-Garcia
Pablo Molina-Garcia
JMJairo H. Migueles
Jairo H. Migueles
CCCristina Cadenas-Sanchez
Cristina Cadenas-Sanchez
IEIrene Esteban‐Cornejo
Irene Esteban‐Cornejo
JMJose Mora-Gonzalez
Jose Mora-Gonzalez
FOFrancisco B. Ortega
Francisco B. Ortega

3 December 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JMJairo H Migueles
Jairo H Migueles
CCCristina Cadenas-Sanchez
Cristina Cadenas-Sanchez
ARAlex Rowlands
Alex Rowlands
PHPontus Henriksson
Pontus Henriksson
ESEric J. Shiroma
Eric J. Shiroma
FOFrancisco B. Ortega
Francisco B. Ortega
Large epidemiological studies that use accelerometers for physical behavior and sleep assessment differ in the location of the accelerometer attachment and the signal aggregation metric chosen. This study aimed to assess the comparability of acceleration metrics between commonly-used body-attachment locations for 24 hours, waking and sleeping hours, and to test comparability of PA cut points between dominant and non-dominant wrist. Forty-five young adults (23 women, 18–41 years) were included and GT3X + accelerometers (ActiGraph, Pensacola, FL, USA) were placed on their right hip, dominant, and non-dominant wrist for 7 days. We derived Euclidean Norm Minus One g (ENMO), Low-pass filtered ENMO (LFENMO), Mean Amplitude Deviation (MAD) and ActiGraph activity counts over 5-second epochs from the raw accelerations. Metric values were compared using a correlation analysis, and by plotting the differences by time of the day. Cut points for the dominant wrist were derived using Lin’s concordance correlation coefficient optimization in a grid of possible thresholds, using the non-dominant wrist estimates as reference. They were cross-validated in a separate sample (N = 36, 10 women, 22–30 years). Shared variances between pairs of acceleration metrics varied across sites and metric pairs (range in r2: 0.19–0.97, all p < 0.01), suggesting that some sites and metrics are associated, and others are not. We observed higher metric values in dominant vs. non-dominant wrist, thus, we developed cut points for dominant wrist based on ENMO to classify sedentary time (<50 mg), light PA (50–110 mg), moderate PA (110–440 mg) and vigorous PA (≥440 mg). Our findings suggest differences between dominant and non-dominant wrist, and we proposed new cut points to attenuate these differences. ENMO and LFENMO were the most similar metrics, and they showed good comparability with MAD. However, counts were not comparable with ENMO, LFENMO and MAD.

9 July 2024 in Journal of Science and Medicine in Sport
Verified
Journal Article
Open access
IPInmaculada Pérez-Prieto
Inmaculada Pérez-Prieto
APAbel Plaza-Florido
Abel Plaza-Florido
EUEsther Ubago-Guisado
Esther Ubago-Guisado
FOFrancisco B. Ortega
Francisco B. Ortega
SASigne Altmäe
Signe Altmäe
The effects of physical activity and sedentary behavior on human health are well known, however, the molecular mechanisms are poorly understood. Growing evidence points to physical activity as an important modulator of the composition and function of microbial communities, while evidence of sedentary behavior is scarce. We aimed to synthesize and meta-analyze the current evidence about the effects of physical activity and sedentary behavior on microbiome across different body sites and in different populations. A systematic search in PubMed, Web of Science, Scopus and Cochrane databases was conducted until September 2022. Random-effects meta-analyses including cross-sectional studies (active vs. inactive / athletes vs. non-athletes) or trials reporting the chronic effect of physical activity interventions on gut microbiome alpha-diversity in healthy individuals were performed. Ninety-one studies were included in this systematic review. Our meta-analyses of 2632 participants indicated no consistent effect of physical activity on microbial alpha-diversity, although there seems to be a trend toward a higher microbial richness in athletes compared to non-athletes. Most of studies reported an increase in short-chain fatty acids-producing bacteria such as Akkermansia, Faecalibacterium, Veillonella or Roseburia in active individuals and after physical activity interventions. Physical activity levels were positively associated with the relative abundance of short-chain fatty acids-producing bacteria. Athletes seem to have a richer microbiome compared to non-athletes. However, high heterogeneity between studies avoids to obtain conclusive information on the role of physical activity in microbial composition. Future multi-omics studies would enhance our understanding of the molecular effects of physical activity and sedentary behavior on the microbiome.

9 July 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
APAbel Plaza-Florido
Abel Plaza-Florido
JAJ. M. A. Alcantara
J. M. A. Alcantara
JMJ. H. Migueles
J. H. Migueles
FAF. J. Amaro-Gahete
F. J. Amaro-Gahete
FAF. M. Acosta
F. M. Acosta
FOF. B. Ortega
F. B. Ortega
Heart rate variability (HRV) is a valid and non-invasive indicator of cardiac autonomic nervous system functioning. Short-term HRV recordings (e.g., 10 min long) produce data that usually is manually processed. Researcher subjective decision-making on data processing could produce inter- or intra-researcher differences whose magnitude has not been previously quantified in three independent human cohorts. This study examines the inter- and intra-researcher reproducibility of HRV parameters (i.e., the influence of R–R interval selection by different researchers and by the same researcher in different moments on the quantification of HRV parameters, respectively) derived from short-term recordings in a cohort of children with overweight/obesity, young adults and middle-age adults. Participants were recruited from 3 different studies: 107 children (10.03 ± 1.13 years, 58% male), 132 young adults (22.22 ± 2.20 years, 33% males) and 73 middle-aged adults (53.62 ± 5.18 years, 48% males). HRV was measured using a Polar RS800CX heart rate monitor. The intraclass correlation coefficient (ICC) ranged from 0.703 to 0.989 and from 0.950 to 0.998 for inter-and intra-researcher reproducibility, respectively. Limits of agreement for HRV parameters were higher for the inter-researcher processing compared with the intra-researcher processing. On average, the intra-researcher differences were 31%, 62%, and 80% smaller than the inter-researchers differences based on Coefficient of Variation in children, young and middle-aged adults, respectively. Our study provides the quantification of the inter-researcher and intra-researcher differences in three independent human cohorts, which could elicit some clinical relevant differences for HRV parameters. Based on our findings, we recommend the HRV data signal processing to be performed always by the same trained researcher and we postulate a development of algorithms for an automatic ECG selection.

27 August 2021 in Polish Heart Journal
Verified
Journal Article
Closed access
PDF file
APAbel Plaza-Florido
Abel Plaza-Florido
JSJerzy Sacha
Jerzy Sacha
JAJuan Ma Alcantara
Juan Ma Alcantara
Low values on heart rate variability (HRV) derived parameters at resting have been used to predict cardiovascular diseases (CVD) and mortality. In this regard, short-term HRV recordings (usually from 5-min to 15-min) are increasing their popularity because data acquisition can be performed under more controlled conditions than long-term recordings (e.g., 24-h). However, different methodological aspects before, during, and after the HRV assessment could affect the quantification and the clinical interpretations of the HRV derived parameters, as well as hampers comparisons across different studies. Here, we summarize these methodological aspects that should be considered in both the research and the clinical settings. These are: 1) the validity and reproducibility of the device used to assess the HRV; 2) the influence of the software used to perform the artefact correction; 3) previous conditions before the testing day; 4) establish the proper conditions during the HRV assessment (e.g., controlled respiratory frequency); 5) after assessing the HRV, consider the "best" data selection and statistical analyses approach; and, 6) the role of the heart rate on the associations between the different CVD risk factors outcomes (e.g., cardiorespiratory fitness) and the HRV derived parameters.