Adrian-Emanuel Magheț

Mr. Adrian-Emanuel Magheț

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AMAdrian-Emanuel Magheț
Adrian-Emanuel Magheț
SISimona ILIE
Simona ILIE
DTDumitru Toader
Dumitru Toader
Photovoltaic (PV) module manufacturers typically provide electrical parameters at Standard Test Conditions (STCs), while real operation is strongly influenced by irradiance and module temperature. This paper presents a MATLAB-based numerical model that simulates the operation of a real PV string composed of 19 series-connected modules (8.645 kWp). Each module has 72 PV cells arranged as two parallel cell groups, each group consisting of 36 cells connected in series, and a rated maximum power of 455 Wp. The validated string belongs to a PV site comprising 140 modules (63.7 kWp); however, the experimental verification is intentionally performed at the string level to avoid aggregation effects. The model implements the single-diode equivalent circuit and computes the I–V and P–V characteristics at any time step, using 500 points for curve plotting. Measured irradiance and module temperature are used as inputs, while DC voltage, current, and power recorded at the inverter MPPT are used as reference quantities. Model performance is evaluated over two representative operating days, and the verification includes point-by-point comparisons between measured and simulated electrical quantities at 25 operating points, with accuracy quantified through MAE, RMSE, and MRE. The obtained errors are: MAE—power 92.94 W (1.08% of maximum power), voltage 8.33 V (1.07% of maximum voltage), current 0.12 A (1.17% of maximum current); RMSE—power 111.78 W (1.29%), voltage 10.15 V (1.30%), current 0.15 A (1.46%); and MRE—power 2.6%, voltage 1.18%, current 2.57%. These results indicate close agreement between simulated and measured string behavior under the tested conditions, supporting the use of the proposed approach for string-level performance analysis and diagnostic assessment when irradiance and temperature are available from measurements or scenario inputs, without extending conclusions to plant-level generalization beyond the validated subsystem. Photovoltaic panel manufacturers usually provide electrical parameters in a single operating condition, but in reality, PV cells operate under very diverse weather conditions. For this reason, the manufacturer’s information is not sufficient to determine the performance of PV plants.

11 July 2026 in Electronics
Verified
Journal Article
Open access
PDF file
AMAdrian-Emanuel Magheț
Adrian-Emanuel Magheț
DTDumitru Toader
Dumitru Toader
SISimona ILIE
Simona ILIE
This paper presents a global solar irradiance measurement system developed at Politehnica University Timisoara (UPT), comprising a Kipp & Zonen CMP11 thermopile pyranometer (Kipp & Zonen, OTT HydroMet B.V., Delft, The Netherlands), a National Instruments myDAQ board (National Instruments Corporation, Austin, TX, USA), and a LabVIEW 2018 interface (National Instruments Corporation, Austin, TX, USA). The platform provides configurable acquisition, voltage-to-irradiance conversion, temporal averaging, data storage, and MATLAB R2024b-based analysis (The MathWorks, Inc., Natick, MA, USA). A preliminary operational validation was performed against ten-minute global-irradiance data supplied by the National Meteorological Administration of Romania (ANM) at the same site. The dataset comprised five non-consecutive days between December 2025 and May 2026, with 215 paired values. The global metrics were MBE = −0.33 W/m2, MAE = 4.55 W/m2, RMSE = 6.05 W/m2, nRMSE = 1.29%, and MARE = 0.96%. Incident solar energy was 60.357 MJ/m2 for UPT and 60.399 MJ/m2 for ANM, a relative difference of −0.07%. Day-specific Bland–Altman analyses showed 0.00–4.65% of differences outside the corresponding limits of agreement. Regression of the differences against the pairwise mean irradiance identified an irradiance-dependent bias component in the combined dataset. The results demonstrate promising operational agreement under the tested conditions. Longer campaigns and traceable low-level characterization of the acquisition chain remain necessary for extended metrological assessment.

1 January 2025
Verified
Conference Paper
Closed access
SISimona ILIE
Simona ILIE
AMAdrian-Emanuel Magheț
Adrian-Emanuel Magheț
ILIoan Luminosu
Ioan Luminosu
Politehnica University of Timișoara (UPT) has been at the forefront of solar energy research and applications in Romania, with a history spanning almost five decades, since its early beginnings in the 1970s. UPT has engaged in both thermosolar and photovoltaic (PV) projects, contributing significantly to the advancement of renewable energy technologies. In the first years, solar energy was studied by research teams with good positive impact on fields such as construction, thermotechnics, electromechanics, and electric and electronic fields. Different research teams performed measurements and simulations with good results on solar radiation, study of materials, different solar collectors, solar concentrators, a solar house, and many more.