Agha Syed Muhammad Gillani

Dr. Agha Syed Muhammad Gillani


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
AGAgha Syed Muhammad Gillani
Agha Syed Muhammad Gillani
SLSeung-Geon Lee
Seung-Geon Lee
SLSoo-Hyung Lee
Soo-Hyung Lee
HLHyerin Lee
Hyerin Lee
KHKee-Jeung Hong
Kee-Jeung Hong
Twelve full-scale reinforced concrete beams with two tension lap splices were constructed and tested under a four-point loading test. Half of these beams had shorter lap splices than that recommended by American Concrete Institute Building Code ACI 318-19; they failed by bond loss between steel and concrete at the lap splice region before rebar yielding. The other half of the beams were designed with a lap splice length slightly exceeding that recommended by ACI 318-19; they failed by rebar yielding and exhibited a ductile behavior. Several strain gauges were attached to the longitudinal bars in the lap splice region to study the local behavior of deformed bars during loading. The strain in a rebar was maximum at the loaded end of the lap splice and progressively decreased toward the unloaded end because the rebar at this end could not sustain any load. Stress flow discontinuity occurred at the loaded end and caused stress concentration. The effect of this concentration was investigated based on test results. The comparison of bond strengths calculated by existing equations and those of tested specimens indicated that the results agreed well.

24 November 2025 in Materials
Verified
Journal Article
Open access
PDF file
AGAgha Syed Muhammad Gillani
Agha Syed Muhammad Gillani
CYChongku Yi
Chongku Yi
KHKee-Jeung Hong
Kee-Jeung Hong
The Korean Highway Bridge Design Code introduced requirements for sufficient tensile lap-splice lengths in 2005. Bridge piers designed before 2005 might not have enough tensile lap-splice length. In addition to that, old structures are susceptible to corrosion due to several environmental factors. Thus, to investigate the effect of lap-splice lengths on the bending behavior of the old piers, twelve reinforced concrete (RC) beams were fabricated with sufficient and insufficient tensile lap-splice length, electrochemically corroded and tested under bending. Six of these beams, with sufficient lap-splice lengths, failed in a ductile manner after reinforcement bar (rebar) yielding occurred, whereas the remaining six, with insufficient lap-splice lengths, failed in a brittle manner owing to lap-splice bond failure before rebar yielding. The tested low-corrosion (< 4% by mass) beams exhibited significantly higher load-carrying capacities than non-corroded counterparts tested in our previous study. These results correlated with previously reported results by other researchers, indicating that low corrosion levels do not critically compromise the flexural performance of RC piers. Nevertheless, piers featuring insufficient lap-splice lengths must be rehabilitated to ensure seismically sufficient ductile flexural behavior.