Ahmed K. El-Sayed

Dr. Ahmed K. El-Sayed

King Saud Univerisity
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2010 in Journal of Composites for Construction
Verified
Journal Article
Closed access
Ehab A. AhmedEhab A. Ahmed
Ehab A. Ahmed
AEAhmed K. El-Sayed
Ahmed K. El-Sayed
EEEhab El-Salakawy
Ehab El-Salakawy
BBBrahim M. Benmokrane
Brahim M. Benmokrane
This paper provides a comparison and evaluation of the current test methods used to determine the strength of fiber-reinforced polymer (FRP) bent bars/stirrups at the bend location (bend strength). The available methods depend on applying tensile forces through the straight portion of the bent bar/stirrup and keeping the bend zone restrained to generate a stress perpendicular to the bend direction in addition to the stress in the longitudinal direction. This could be achieved through the ACI 440.3R-04 B.12 test method for U-shaped bare FRP bars. Another possible method is the ACI 440.3R-04 B.5 which evaluates the bend strength of FRP stirrups by embedding them in two concrete blocks, which are pushed apart until the rupture of the FRP bent bars. Both methods were employed in testing FRP stirrups and bent bars and the bend strength was compared. The test results showed that the ACI 440.3R-04 B.12 test method consistently underestimates the bend strength of FRP stirrups. On the other hand, B.5 test method i...

1 April 2005 in Journal of Composites for Construction
Verified
Journal Article
Closed access
AEAhmed K. El-Sayed
Ahmed K. El-Sayed
EEEhab El-Salakawy
Ehab El-Salakawy
BBBrahim M. Benmokrane
Brahim M. Benmokrane
This paper evaluates the shear strength of one-way concrete slabs reinforced with different types of fiber-reinforced polymer (FRP) bars. A total of eight full-size slabs were constructed and tested. The slabs were 3,100 mm long× 1,000 mm wide×200 mm deep . The test parameters were the type and size of FRP reinforcing bars and the reinforcement ratio. Five slabs were reinforced with glass FRP and three were reinforced with carbon FRP bars. The slabs were tested under four-point bending over a simply supported clear span of 2,500 mm and a shear span of 1,000 mm. All the test slabs failed in shear before reaching the design flexural capacity. The experimental shear strengths were compared with some theoretical predictions, including the JSCE recommendations, the CAN/CSA-S806-02 code, and the ACI 440.1R-03 design guidelines. The results indicated that the ACI 440.1R-03 design method for predicting the concrete shear strength of FRP slabs is very conservative. Better predictions were obtained by both the CAN/...

1 August 2007 in Journal of Composites for Construction
Verified
Journal Article
Closed access
AEAhmed K. El-Sayed
Ahmed K. El-Sayed
EEEhab El-Salakawy
Ehab El-Salakawy
BBBrahim M. Benmokrane
Brahim M. Benmokrane
This paper describes an experimental program conducted to develop new carbon fiber reinforced polymer (CFRP) stirrups as shear reinforcement for concrete members. The structural behavior of the CFRP stirrups was examined. To simulate the performance mechanism of stirrups in concrete beams, the CFRP stirrup was embedded in two concrete blocks and tested in tension by pushing the concrete blocks away from each other. A total of 12 specimens were constructed and tested to failure. The test variables were the tail length of the stirrup beyond the bent portion, the stirrup anchorage, the bar diameter, and the embedment length. In addition, two full-scale concrete beams reinforced with CFRP stirrups as shear reinforcement were constructed and tested to failure. Test results of the concrete blocks indicated that the strength capacity at the bend of the newly developed CFRP stirrups was adequate and fulfilled the design requirements of different codes and design guides. Further, the tail length was found to be no...

1 May 2012 in Canadian Journal of Civil Engineering
Verified
Journal Article
Closed access
AEAhmed K. El-Sayed
Ahmed K. El-Sayed
EEEhab F. El-Salakawy
Ehab F. El-Salakawy
BBBrahim Benmokrane
Brahim Benmokrane

1 January 2012 in Journal of King Saud University – Engineering Sciences
Verified
Journal Article
Open access
KSKhaled Soudki
Khaled Soudki
AEAhmed K. El-Sayed
Ahmed K. El-Sayed
TVTim Vanzwol
Tim Vanzwol
This paper presents experimental data and results on the effect of externally bonded carbon fiber-reinforced polymer (CFRP) strips on the punching shear of interior slab-column connections. A total of six square slabs with a concentric column were constructed with overall dimensions of 1220mm by 1220mm and 100mm thick slab and 150×150mm column. The test variables were the configuration and amount of CFRP strips externally bonded to the tension face of the slab. The specimens were simply supported along their edges and tested in punching with vertical load applied through the central column. The test results clearly showed that CFRP strengthening leads to significant improvements in the structural behaviour of slab-column connections. The increase in punching capacity of strengthened slabs was up to 29%, while the increase in stiffness was up to 80% compared to the unstrengthened slab. Punching capacities of the test specimens were evaluated using a recently developed model that accounts for both configuration and amount of CFRP strips. The predicted punching capacities using the analytical model were compared with the experimental results, and good agreement was found

1 February 2011 in Journal of Composites for Construction
Verified
Journal Article
Closed access
AEAhmed K. El-Sayed
Ahmed K. El-Sayed
KSKhaled Soudki
Khaled Soudki
Several codes and design guidelines addressing fiber-reinforced polymer (FRP) bars as primary reinforcement for structural concrete have been recently published worldwide. This reflects the great progress in FRP research area that has been conducted by the research community over the past two decades. Most of these design provisions follow the traditional approach of Vc + Vs for shear design. Nevertheless, both equations of concrete contribution Vc and FRP stirrup contribution Vs to shear strength in these guidelines are different in the manner that they are calculated. In this paper, five methods for FRP shear design, currently used in design practice, were reviewed. These methods include the American Concrete Institute design guide, ACI 440.1R-06; the Canadian Standards Association, CAN/CSA-S806-02; the ISIS Canada design manual, ISIS-M03-07; the British Institution of Structural Engineers guidelines; and the design recommendations of the Japan Society of Civil Engineers. The five methods for shear desi...