Ehab A. Ahmed

Dr. Ehab A. Ahmed

Department of Civil Engineering, Toronto Metropolitan University, 350 Victoria St., Toronto, ON M5B 2K3, Canada
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2010 in Journal of Composites for Construction
Verified
Journal Article
Closed access
Ehab A. AhmedEhab A. Ahmed
Ehab A. Ahmed
AEAhmed K. El-Sayed
Ahmed K. El-Sayed
EEEhab El-Salakawy
Ehab El-Salakawy
BBBrahim M. Benmokrane
Brahim M. Benmokrane
This paper provides a comparison and evaluation of the current test methods used to determine the strength of fiber-reinforced polymer (FRP) bent bars/stirrups at the bend location (bend strength). The available methods depend on applying tensile forces through the straight portion of the bent bar/stirrup and keeping the bend zone restrained to generate a stress perpendicular to the bend direction in addition to the stress in the longitudinal direction. This could be achieved through the ACI 440.3R-04 B.12 test method for U-shaped bare FRP bars. Another possible method is the ACI 440.3R-04 B.5 which evaluates the bend strength of FRP stirrups by embedding them in two concrete blocks, which are pushed apart until the rupture of the FRP bent bars. Both methods were employed in testing FRP stirrups and bent bars and the bend strength was compared. The test results showed that the ACI 440.3R-04 B.12 test method consistently underestimates the bend strength of FRP stirrups. On the other hand, B.5 test method i...

1 June 2017 in Journal of Composites for Construction
Verified
Journal Article
Closed access
FEFareed Elgabbas
Fareed Elgabbas
Ehab A. AhmedEhab A. Ahmed
Ehab A. Ahmed
BBBrahim M. Benmokrane
Brahim M. Benmokrane
Recently, basalt fiber–reinforced polymer (BFRP) reinforcement emerged as a new FRP type. Research is needed, however, to understand the behavior of BFRP bars in concrete members. This paper presents an experimental study aimed at investigating the flexural behavior and serviceability performance of concrete beams reinforced with ribbed BFRP bars. A total of eight concrete beams measuring 3,100 mm in length×200 mm in width×300 mm in depth were constructed and tested up to failure. Six beams were reinforced with 8-, 12-, and 16-mm BFRP bars with ribbed surfaces and two reference beams were reinforced with 10M and 15M steel bars. The beam specimens were designed in accordance with Canadian standards, and tested under four-point bending over a clear span of 2,700 mm until failure. The test results are presented and discussed in terms of cracking behavior, deflection, and failure modes. The test results yielded an average bond-dependent coefficient (kb) of 0.83, which is lower than 1.0 recommended b...

1 December 2013 in Journal of Composites for Construction
Verified
Journal Article
Closed access
MHMohamed Hassan
Mohamed Hassan
Ehab A. AhmedEhab A. Ahmed
Ehab A. Ahmed
BBBrahim M. Benmokrane
Brahim M. Benmokrane
This paper investigated the punching-shear behavior of two-way concrete slabs reinforced with glass fiber–reinforced polymer (GFRP) bars of different grades. A total of 10 full-scale interior slab-column specimens measuring 2,500×2,500 mm with thicknesses of either 200 or 350 mm and 300×300 mm square column stubs were fabricated with normal and high-strength concretes. The specimens were tested under monotonic concentric loading until failure. The effects of concrete strength as well as reinforcement type and ratio were evaluated. The test results revealed that increasing the reinforcement ratio resulted in higher punching-shear capacity, lower reinforcement and concrete strains, and lower deflections. In addition, the high-strength concrete increased the punching-shear capacity, significantly reduced concrete strains, increased strains in the GFRP reinforcing bars, and reduced deflection due to the high tensile strength and modulus of elasticity. The test results and results from literature wer...

1 January 2010 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
Ehab A. AhmedEhab A. Ahmed
Ehab A. Ahmed
EEEhab F. El-Salakawy
Ehab F. El-Salakawy
BBBrahim M. Benmokrane
Brahim M. Benmokrane
One of the main components in girder-type bridges is bridge girder. This paper presents experimental data on the behavior and shear strength of concrete bridge girders reinforced with carbon fiber-reinforced polymer (CFRP) stirrups. A total of four large-scale reinforced concrete beams with a total length of 7,000 mm and a T-shaped cross section were constructed and tested up to failure. The test variables were the type and ratio of shear reinforcement (stirrups). The test beams included three beams reinforced with sand-coated CFRP stirrups of 9.5-mm-diameter spaced at d/2 , d/3 , and d/4 (where d is the beam depth) and a control beam reinforced with conventional steel stirrups of 9.5-mm-diameter spaced at d/2 . The geometry of the test prototypes were selected to simulate the New England Bulb Tee (NEBT) beams that are being used by the Ministry of Transportation of Québec, Canada. As designed, three beams failed in shear due to CFRP stirrup rupture or steel stirrup yielding. While, the forth one, reinfor...

1 July 2016 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
FEFareed Elgabbas
Fareed Elgabbas
Ehab A. AhmedEhab A. Ahmed
Ehab A. Ahmed
BBBrahim M. Benmokrane
Brahim M. Benmokrane
Advances in fiber-reinforced polymer (FRP) technology have led to the introduction of new basalt-fiber-reinforced-polymer (BFRP) bars. This paper presents a research project investigating the behavior of edge-restrained concrete bridge-deck slabs reinforced with BFRP bars. The tests included six full-scale edge-restrained concrete deck slabs simulating a slab-on-girder bridge deck commonly used in North America and one full-scale unrestrained concrete deck slab. The deck slabs measured 3,000 mm long × 2,500 mm wide × 200 mm thick. The test parameters investigated were (1) reinforcement type (BFRP and steel); (2) BFRP bar size (12 and 16 mm); (3) reinforcement ratio in each direction (0.4–1.2%); and (4) edge-restraining [restrained or unrestrained (free)].The slabs were tested up to failure over a center-to-center span of 2,000 mm under a single concentrated load acting on the center of each slab over a contact area of 600 × 250 mm to simulate the footprint of a sustained truck wheel load (87.5-kN ...

1 February 2017 in Journal of Composites for Construction
Verified
Journal Article
Closed access
Ehab A. AhmedEhab A. Ahmed
Ehab A. Ahmed
BBBrahim M. Benmokrane
Brahim M. Benmokrane
MSMaxime Sansfaçon
Maxime Sansfaçon
Parking garages are among the concrete structures that suffer from corrosion and deterioration due to exposure to deicing salts. The 40-year-old La Chancelière parking garage in Québec (Canada) showed severe corrosion-related deterioration and was in need of costly rehabilitation. As its structural system consisted of two-way flat slabs and the steel reinforcement was severely corroded in most of the slabs, the City of Québec (structure’s owner) decided to replace the structure’s flat slabs (a total area of about 3,160  m2 ) with new ones, while maintaining the main supporting elements (columns and retaining walls). The consulting firm produced two designs with steel reinforcing bars and glass-fiber-reinforced polymer (GFRP) reinforcing bars. Based on the comparative cost analysis of the steel-reinforced and GFRP-reinforced designs, the city opted for GFRP bars. The flat-slab system was designed according to CAN/CSA S806-12 with GFRP bars as main reinforcement, the world’s first application of its type. The slabs were instrumented at critical locations to measure strain with fiber-optic sensors (FOSs) attached to the surface of the GFRP bars or embedded in concrete. This study provides details on the design, construction, and performance of GFRP-reinforced-concrete (GFRP-RC) flat slabs under real service loads and conditions over 3.5 years. In addition, it provides a comparative cost analysis of the steel-RC and GFRP-RC designs. The cost comparison confirms that the initial higher cost of GFRP compared to steel does not necessarily lead to a higher total cost and that a cost-effective design could be achieved.