Ahmed Kazaili

Dr. Ahmed Kazaili

University of Liverpool, Liverpool, UK
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2020 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
Vito RomanoVito Romano
Vito Romano
Ahmed KazailiAhmed Kazaili
Ahmed Kazaili
LPLuca Pagano
Luca Pagano
KGKunal Ajit Gadhvi
Kunal Ajit Gadhvi
MTMitchell Titley
Mitchell Titley
MPMohit Parekh
Mohit Parekh
Aim To investigate the difference in adhesion and rebubbling rate between eye bank and surgeon prepared Descemet membrane endothelial keratoplasty (DMEK) tissues. Methods Laboratory and clinical retrospective comparative interventional case series. Research corneal tissues were obtained for laboratory investigation. The clinical study involved patients with endothelial dysfunction who underwent DMEK surgery and tamponade with air. Tissues were stripped using a standard DMEK stripping technique (SCUBA) and shipped as prestripped or loaded in a 2.2 intra-ocular lens cartridge with endothelium facing inwards (preloaded) before transporting from the eye bank to the surgeon. For surgeon prepared tissues, all the grafts were stripped in the theatre and transplanted or stripped in the laboratory and tested immediately. Adhesion force and elastic modulus were measured in the centre and mid-periphery in a laboratory ex vivo investigation using atomic force microscopy, while rebubbling rates were recorded in the clinical study. Results There was no difference in endothelial cell viability between surgeon or eye bank prepared tissue. Surgeon-stripped DMEK grafts in the laboratory investigation showed significantly higher elastic modulus and adhesion force compared to prestripped and preloaded tissues (p<0.0001). In the clinical data, rebubbling rates of 48%, 40% and 15% were observed in preloaded, prestripped and surgeon-stripped DMEK grafts, respectively. Rebubbling rates were significantly associated with combined cataract surgery (p=0.009) and with time from harvesting the graft to the surgery (p=0.02). Conclusions Decreased adhesion forces and elastic modulus in eye bank prepared tissues may contribute to increased rebubbling rates.

1 December 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Ahmed KazailiAhmed Kazaili
Ahmed Kazaili
BGBrendan Geraghty
Brendan Geraghty
Riaz AkhtarRiaz Akhtar
Riaz Akhtar

26 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Ahmed KazailiAhmed Kazaili
Ahmed Kazaili
Hayder makkiHayder makki
Hayder makki
Jillian MadineJillian Madine
Jillian Madine
Riaz AkhtarRiaz Akhtar
Riaz Akhtar
Under physiological conditions, the cornea is exposed to various enzymes, some of them have digestive actions, such as amylase and collagenase that may change the ultrastructure (collagen morphology) and sequentially change the mechanical response of the cornea and distort vision, such as in keratoconus. This study investigates the ultrastructure and nanomechanical properties of porcine cornea following incubation with α-amylase and collagenase. Atomic force microscopy (AFM) was used to capture nanoscale topographical details of stromal collagen fibrils (diameter and D-periodicity) and calculate their elastic modulus. Samples were incubated with varying concentrations of α-amylase and collagenase (crude and purified). Dimethylmethylene blue (DMMB) assay was utilised to detect depleted glycosaminoglycans (GAGs) following incubation with amylase. Collagen fibril diameters were decreased following incubation with amylase, but not D-periodicity. Elastic modulus was gradually decreased with enzyme concentration in amylase-treated samples. Elastic modulus, diameter, and D-periodicity were greatly reduced in collagenase-treated samples. The effect of crude collagenase on corneal samples was more pronounced than purified collagenase. Amylase was found to deplete GAGs from the samples. This enzymatic treatment may help in answering some questions related to keratoconus, and possibly be used to build an empirical animal model of keratoconic corneas with different progression levels.

1 January 2022 in Indian Journal Of Ophthalmology
Verified
Journal Article
Open access
VRVito Romano
Vito Romano
MPMohit Parekh
Mohit Parekh
Ahmed KazailiAhmed Kazaili
Ahmed Kazaili
BSBernhard Steger
Bernhard Steger
RARiaz Akhtar
Riaz Akhtar
HHannah Levis
Hannah Levis
Purpose: To evaluate and compare the biomechanical properties of the eye bank-prepared and surgeon prepared Descemet stripping automated endothelial keratoplasty (DSAEK) tissues. Methods: In this laboratory study, corneal tissues for research were randomly allocated in the following groups: a) surgeon-cut DSAEK and b) eye bank-prepared (pre-cut and pre-loaded) DSAEK. Endothelial cell loss (ECL), immunostaining for tight junction protein ZO-1, elastic modulus, and adhesion force were investigated. Results: ECL was not found to be significantly different between surgeon-cut DSAEK (7.8% ±6.5%), pre-cut DSAEK (8.6% ±2.3%), and pre-loaded DSAEK (11.1% ±4.8%) (P = 0.5910). ZO-1 was expressed equally across all groups. Surgeon-cut DSAEK grafts showed a significantly higher elastic modulus compared to pre-cut and pre-loaded DSAEK groups (P = 0.0047 and P < 0.0001, respectively). Adhesion force was significantly greater in the surgeon-cut DSAEK compared to pre-cut (P < 0.0001) or pre-loaded DSAEK groups (P = 0.0101). Conclusion: The laboratory data on the biomechanics of DSAEK grafts suggests that surgeon-cut DSAEK grafts present higher elastic modulus and adhesion force compared to eye bank-prepared DSAEK grafts.

1 January 2022 in Experimental Eye Research
Verified
Journal Article
Closed access
Bandar M. AleneziBandar M. Alenezi
Bandar M. Alenezi
Ahmed KazailiAhmed Kazaili
Ahmed Kazaili
Riaz AkhtarRiaz Akhtar
Riaz Akhtar
HRHema Radhakrishnan
Hema Radhakrishnan

19 April 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Ahmed KazailiAhmed Kazaili
Ahmed Kazaili
SLSamuel Lawman
Samuel Lawman
BGBrendan Geraghty
Brendan Geraghty
AEAshkan Eliasy
Ashkan Eliasy
YZYalin Zheng
Yalin Zheng
Riaz AkhtarRiaz Akhtar
Riaz Akhtar
There has been a lot of interest in accurately characterising corneal biomechanical properties under intraocular pressure (IOP) to help better understand ocular pathologies that are associated with elevated IOP. This study investigates the novel use of Line-Field Optical Coherence Tomography (LF-OCT) as an elastographic tool for accurately measuring mechanical properties of porcine corneas based on volumetric deformation following varying IOPs. A custom-built LF-OCT was used to measure geometrical and corneal surface displacement changes in porcine corneas under a range of IOPs, from 0–60 mmHg. Corneal thickness, elastic properties and hysteresis were calculated as a function of pressure. In addition, the effects of hydration were explored. We found that the elastic modulus increased in a linear fashion with IOP. Corneal thickness was found to reduce with IOP, decreasing 14% from 0 to 60 mmHg. Prolonged hydration in phosphate buffered saline (PBS) was found to significantly increase the elastic modulus and corneal hysteresis. Our study demonstrates that LF-OCT can be used to accurately measure the elastic properties based on volumetric deformation following physiological pressures. Furthermore, we show that prolonged hydration in PBS has a significant effect on the measured corneal properties.