Samuel Lawman

Dr. Samuel Lawman

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
MBMatthias Brunner
Matthias Brunner
Vito RomanoVito Romano
Vito Romano
BSBernhard Steger
Bernhard Steger
RVRiccardo Vinciguerra
Riccardo Vinciguerra
SLSamuel Lawman
Samuel Lawman
SKStephen B. Kaye
Stephen B. Kaye

27 May 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
SLSamuel Lawman
Samuel Lawman
YDYue Dong
Yue Dong
BWBryan Williams
Bryan Williams
Vito RomanoVito Romano
Vito Romano
SKStephen Kaye
Stephen Kaye
Yalin ZhengYalin Zheng
Yalin Zheng
We report the development of a Spectral Domain Line Field Optical Coherence Tomography (LF-OCT) system, using a broad bandwidth and spatial coherent Super-Continuum (SC) source. With conventional quasi-Continuous Wave (CW) setup we achieve axial resolutions up to 2.1 μm in air and 3D volume imaging speeds up to 213 kA-Scan/s. Furthermore, we report the use of a single SC pulse, of 2 ns duration, to temporally gate an OCT B-Scan image of 70 A-Scans. This is the equivalent of 35 GA-Scans/s. We apply the CW setup for high resolution imaging of the fine structures of a human cornea sample ex-vivo. The single pulse setup is applied to imaging of a coated pharmaceutical tablet. The fixed pattern noise due to spectral noise is removed by subtracting the median magnitude A-Scan. We also demonstrate that the Fourier phase can be used to remove aberration caused artefacts.

29 April 2016 in Applied Optics
Verified
Journal Article
Closed access
PDF file
YDYue Dong
Yue Dong
SLSamuel Lawman
Samuel Lawman
Yalin ZhengYalin Zheng
Yalin Zheng
DWDominic Williams
Dominic Williams
JZJinke Zhang
Jinke Zhang
Yaochun ShenYaochun Shen
Yaochun Shen
We have demonstrated for the first time, to our knowledge, the use of optical coherence tomography (OCT) as an analytical tool for nondestructively characterizing the individual paint layer thickness of multiple layered automotive paints. A graph-based segmentation method was used for automatic analysis of the thickness distribution for the top layers of solid color paints. The thicknesses measured with OCT were in good agreement with the optical microscope and ultrasonic techniques that are the current standard in the automobile industry. Because of its high axial resolution (5.5 μm), the OCT technique was shown to be able to resolve the thickness of individual paint layers down to 11 μm. With its high lateral resolution (12.4 μm), the OCT system was also able to measure the cross-sectional area of the aluminum flakes in a metallic automotive paint. The range of values measured was 300–1850 μm2. In summary, the proposed OCT is a noncontact, high-resolution technique that has the potential for inclusion as part of the quality assurance process in automobile coating.

25 July 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
JZJinke Zhang
Jinke Zhang
BWBryan Williams
Bryan Williams
SLSamuel Lawman
Samuel Lawman
DADavid Atkinson
David Atkinson
ZZZijian Zhang
Zijian Zhang
Yalin ZhengYalin Zheng
Yalin Zheng
Automotive coating systems are designed to protect vehicle bodies from corrosion and enhance their aesthetic value. The number, size and orientation of small metallic flakes in the base coat of the paint has a significant effect on the appearance of automotive bodies. It is important for quality assurance (QA) to be able to measure the properties of these small flakes, which are approximately 10μm in radius, yet current QA techniques are limited to measuring layer thickness. We design and develop a time-domain (TD) full-field (FF) optical coherence tomography (OCT) system to scan automotive panels volumetrically, non-destructively and without contact. We develop and integrate a segmentation method to automatically distinguish flakes and allow measurement of their properties. We test our integrated system on nine sections of five panels and demonstrate that this integrated approach can characterise small flakes in automotive coating systems in 3D, calculating the number, size and orientation accurately and consistently. This has the potential to significantly impact QA testing in the automotive industry.

2 November 2011 in Applied Optics
Verified
Journal Article
Closed access
PDF file
SLSamuel Lawman
Samuel Lawman
HLHaida Liang
Haida Liang
Optical coherence tomography (OCT) has mostly been used for high-speed volume imaging but its profilometry potentials have not been fully exploited. This paper demonstrates high precision (as good as ∼50 nm) multi-interface profilometry using a Fourier domain OCT system without special antivibration devices. The precision is up to 2 orders of magnitude better than the depth resolution of the OCT. Detailed analysis of the precision achieved for different surfaces is presented. The multi-interface profiles are obtained as a by-product of the tomography data. OCT has the advantage in speed and sensitivity at detecting rough and internal interfaces versus conventional optical profilometry. An application of the technique to the dynamic monitoring of varnish drying on paintlike substrates is demonstrated, which provides a better understanding of the formation of surface roughness. The technique has potential benefits in the fields of art conservation, coatings technology, and soft matter physics.

13 November 2017 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
SLSamuel Lawman
Samuel Lawman
PMPeter W. Madden
Peter W. Madden
Vito RomanoVito Romano
Vito Romano
YDYue Dong
Yue Dong
SMSharon Mason
Sharon Mason
YZYalin Zheng
Yalin Zheng
Optical coherence tomography (OCT) can monitor human donor corneas non-invasively during the de-swelling process following storage for corneal transplantation, but currently only resultant thickness as a function of time is extracted. To visualize and quantify the mechanism of de-swelling, we present a method exploiting the nanometer sensitivity of the Fourier phase in OCT data to image deformation velocities. The technique was demonstrated by non-invasively showing during de-swelling that osmotic flow through an intact epithelium is negligible and removing the endothelium approximately doubled the initial flow at that interface. The increased functional data further enabled the validation of a mathematical model of the cornea. Included is an efficient method of measuring high temporal resolution (1 minute demonstrated) corneal thickness, using automated collection and semi-automated graph search segmentation. These methods expand OCT capabilities to measure volume change processes for tissues and materials.