Ahmed Yehia Sayed Ahmed

Dr. Ahmed Yehia Sayed Ahmed

Pharmacy, Riyadh Elm University, Riyadh, Ar Riyāḑ, Saudi Arabia
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Bioorganic Chemistry
Verified
Journal Article
Closed access
HAHamad Alkahtani
Hamad Alkahtani
Ashraf N. AbdallaAshraf N. Abdalla
Ashraf N. Abdalla
AOAhmad J. Obaidullah
Ahmad J. Obaidullah
MAMohammed M. Alanazi
Mohammed M. Alanazi
AAAbdulrahman Almehizia
Abdulrahman Almehizia
AAAdel Azab
Adel Azab

12 June 2020 in Molecules
Verified
Journal Article
Open access
PDF file
SHSaad S. M. Hassan
Saad S. M. Hassan
Ayman H. KamelAyman H. Kamel
Ayman H. Kamel
AHAmr Hassan
Amr Hassan
Abd El-Galil Elsayed AmrAbd El-Galil Elsayed Amr
Abd El-Galil Elsayed Amr
HNHeba Abd El Naby
Heba Abd El Naby
AAAhmed Yehia Sayed Ahmed
Ahmed Yehia Sayed Ahmed
Copper ferrite nano-particles (CuFe2O4) were synthesized, characterized, modified with polyaniline to form CuFe2O4/PANI nano-composite. They were used as new adsorbents for the removal of the hazardous mercuric ions from aqueous solutions. High resolution transmission electron microscope (HR-TEM), X-ray diffraction (XRD), Fourier-transform infrared (FT-IR) and Brunauer–Emmett–Teller (BET) were used for the characterization of the synthesized CuFe2O4 nano-particles (NPs) in presence and absence of PANI nano-composite. The synthesized CuFe2O4NPs were of spherical shape with an average size of 10.8 nm. XRD analysis displayed crystal peaks for CuFe2O4NPs and amorphous peaks CuFe2O4/PANI nano-composite due to the existence of polyaniline layer. Contact time, adsorbent dose, solution pH, adsorption kinetics, adsorption isotherm and recyclability were studied. The method at the optimum conditions exhibited high performance with high mercury removal percentage of up to 99% with a maximum adsorption capacity 12.5 and 157.1 mg/g for CuFe2O4 and CuFe2O4/PANI, respectively. The adsorption processes were fitted to Langmuir isotherms. The adsorption behavior of CuFe2O4@PANI composite towards Hg2+ ions is attributed to the soft acid–soft base strong interaction between PANI and Hg(II) ions. High stability and enhanced re-usability are offered using CuFe2O4@PANI composite due to its enhanced removal efficiency. No significant removal decrease was noticed after five adsorption–desorption cycles. In addition, it possesses an easy removal from aqueous solutions by external magnetic field after adsorption experiments. These indicated the enhancement of polyaniline to the surface of CuFe2O4 toward the adsorption of mercury from aqueous solutions.

22 April 2021 in ACS Omega
Verified
Journal Article
Open access
Abd El-Galil Elsayed AmrAbd El-Galil Elsayed Amr
Abd El-Galil Elsayed Amr
Ayman H. KamelAyman H. Kamel
Ayman H. Kamel
AAAbdulrahman A. Almehizia
Abdulrahman A. Almehizia
AAAhmed Yehia Sayed Ahmed
Ahmed Yehia Sayed Ahmed
EEElsayed A. Elsayed
Elsayed A. Elsayed
HAHisham S. M. Abd-Rabboh
Hisham S. M. Abd-Rabboh
Herein, we describe for the first time, the design and fabrication of a novel nicotine paper-based sensor, in which a miniaturized paper reference electrode is integrated for potentiometric measurements. The paper-based sensors were designed using printed wax barriers to define the electrochemical cell and the sample zones. The electrodes were based on the use of the ion association complexes of the nicotinium cation (Nic) with either tetraphenylborate (TPB) or 5-nitrobarbiturate (NB) counter anions as sensing materials for nicotine recognition. A poly (3,4 ethylenedioxythiophene)/poly-(styrene sulfonate) (PEDOT/PSS) conducting polymer was used as an ion-to-electron transducer. The performance characteristics of the proposed sensors were evaluated and it revealed a rapid and stable response with a Nernstian slope of 55.2 ± 0.3 and 51.2 ± 0.6 mV/decade over the linear range of 1.0 × 10–5 to 1.0 × 10–2 M and detection limits of 6.0 and 8.0 μM for [Nic/TPB] and [Nic/NB], respectively. The sensors revealed a constant response over the pH range 3.5–6.5. The designed sensors provided a portable, inexpensive, and disposable way of measuring trace levels of nicotine coming from different cigarettes and in the collected human sweat of heavy smokers. All results were compared favorably with those obtained by the standard gas chromatographic method.

23 March 2021 in RSC Advances
Verified
Journal Article
Open access
PDF file
HAHisham Abd-Rabboh
Hisham Abd-Rabboh
Abd El-Galil Elsayed AmrAbd El-Galil Elsayed Amr
Abd El-Galil Elsayed Amr
EEElsayed Ahmed Elsayed
Elsayed Ahmed Elsayed
AAAhmed Yehia Sayed Ahmed
Ahmed Yehia Sayed Ahmed
Ayman H. KamelAyman H. Kamel
Ayman H. Kamel
Robust, reliable and cost-effective paper-based analytical device for potentiometric pholcodine (opiate derivative drug) ion sensing has been prepared and characterized. A printed pholcodinium (PHL)2+/5-nitrobarbiturate (NB)− ion-association complex as a sensory material-based all-solid-state ion-selective electrode (ISE) on a chemically reduced graphene oxide (CRGO) solid-contact, and a printed all-solid-state Ag/AgCl reference electrode, has been combined on a hydrophobic paper substrate coated with fluorinated alkyl silane (CF3(CF2)7CH2CH2SiCl3, CF 10). The sensors revealed a potentiometric slope of 28.7 ± 0.3 mV dec−1 (R2 = 0.9998) over a linear range starting from 2.0 × 10−7 M to 1.0 × 10−2 M and a detection limit of 0.04 μg mL−1. The repeatability and stability of the pholcodine paper-based sensor was found to be 2.32%. The RSD% (n = 6) was found to be 2.67% when using five different paper-based sensors. The sensor revealed an excellent selectivity towards PHL over dextromethorphan, codeine, ephedrine, carbinoxamine, caffeine, ketamine, and K+, Na+ and Ca2+ ions. It showed a good recovery (94–104%) for the determination of PHL in different artificial serum samples. The presented paper-based analytical device was successfully introduced for PHL determination in different pharmaceutical formulations (i.e. syrups and suspensions) containing pholcodine. The current work can be considered as a promising possible analytical tool to obtain cost-effective and disposable paper-based potentiometric sensing devices. These devices can be potentially manufacturable at large scales in pharmaceutical, clinical and forensic applications for opiate drug assessment.

1 November 2019 in Polymers
Verified
Journal Article
Open access
PDF file
Ayman H. KamelAyman H. Kamel
Ayman H. Kamel
Abd El-Galil Elsayed AmrAbd El-Galil Elsayed Amr
Abd El-Galil Elsayed Amr
NANashwa Abdalla
Nashwa Abdalla
MNMohamed El Naggar
Mohamed El Naggar
Mohamed A. Al-OmarMohamed A. Al-Omar
Mohamed A. Al-Omar
AAAhmed Yehia Sayed Ahmed
Ahmed Yehia Sayed Ahmed
Novel potentiometric solid-contact ion-selective electrodes (SC/ISEs) based on molecularly imprinted polymers (MIPs) as sensory carriers (MIP/PANI/ISE) were prepared and characterized as potentiometric sensors for flucarbazone herbicide anion. However, aliquat S 336 was also studied as a charged carrier in the fabrication of Aliquat/PANI/ISEs for flucarbazone monitoring. The polyaniline (PANI) film was inserted between the ion-sensing membrane (ISM) and the electronic conductor glassy carbon substrate (GC). The sensors showed a noticeable response towards flucarbazone anions with slopes of −45.5 ± 1.3 (r2 = 0.9998) and −56.3 ± 1.5 (r2 = 0.9977) mV/decade over the range of 10−2–10−5, 10−2–10−4 M and detection limits of 5.8 × 10−6 and 8.5 × 10−6 M for MIP/PANI/ISE and Aliguat/PANI/ISE, respectively. The selectivity and long-term potential stability of all presented ISEs were investigated. The short-term potential and electrode capacitances were studied and evaluated using chronopotentiometry and electrochemical impedance spectrometry (EIS). The proposed ISEs were introduced for the direct measurement of flucarbazone herbicide in different soil samples sprayed with flucarbazone herbicide. The results agree well with the results obtained using the standard liquid chromatographic method (HPLC).

23 June 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Ayman H. KamelAyman H. Kamel
Ayman H. Kamel
Abd El-Galil Elsayed AmrAbd El-Galil Elsayed Amr
Abd El-Galil Elsayed Amr
NANashwa H. Ashmawy
Nashwa H. Ashmawy
HGHoda Galal
Hoda Galal
Mohamed A. Al-OmarMohamed A. Al-Omar
Mohamed A. Al-Omar
AAAhmed Yehia Sayed Ahmed
Ahmed Yehia Sayed Ahmed
Herein, we present for the first time a novel potentiometric sensor based on the stimulus-responsive molecularly imprinted polymer (MIP) as a selective receptor for neutral dopamine determination. This smart receptor can change its capabilities to recognize according to external environmental stimuli. Therefore, MIP-binding sites can be regenerated in the polymeric membrane by stimulating with stimulus after each measurement. Based on this effect, reversible detection of the analyte via potentiometric transduction can be achieved. MIPs based on 4-vinylphenylboronic acid as the functional monomer were prepared as the selective receptor. This monomer can successfully bind to dopamine via covalent binding and forming a five- or six-membered cyclic ester in a weakly alkaline aqueous solution. In acidic medium, the produced ester dissociates and regenerates new binding sites in the polymeric membrane. The proposed smart sensor exhibited fast response and good sensitivity towards dopamine with a limit of detection 0.15 µM over the linear range 0.2–10 µM. The selectivity pattern of the proposed ISEs was also evaluated and revealed an enhanced selectivity towards dopamine over several phenolic compounds. Constant-current chronopotentiometry is used for evaluating the short-term potential stability of the proposed ISEs. The obtained results confirm that the stimulus-responsive MIPs provide an attractive way towards reversible MIP-based electrochemical sensors designation.