A novel approach to developing lateral flow assays (LFAs) for the detection of CYFRA 21-1 (cytokeratin 19 fragment, a molecular biomarker for epithelial-origin cancers) is proposed. Magnetic bioconjugates (MBCs) were employed in combination with advanced optical and magnetic tools to optimize assay conditions. The approach integrates such techniques as label-free spectral-phase interferometry, colorimetric detection, and ultrasensitive magnetometry using the magnetic particle quantification (MPQ) technique. For the first time in LFA applications, the MPQ-based and colorimetry-based detection methods were compared side by side, and superior analytical performance was demonstrated. The limit of detection (LOD) of 0.9 pg/mL was achieved using MPQ, and 2.9 pg/mL with optical detection. This study has demonstrated that MPQ provides elimination of signal saturation, higher sensitivity (slope of the calibration curve), and a 19-fold wider dynamic range of detected signals. Both optical and magnetic detection results are comparable to the best laboratory-based tests with the added benefits of a 20-min assay duration and the LFA format convenience. The assay effectiveness was validated in human serum and artificial saliva, and high recovery rates were observed. The proposed approach offers rapid and reliable detection of molecular biomarkers and holds significant potential for point-of-care diagnostics, particularly in resource-limited settings.
In this study, we present a novel and ultrasensitive magnetic lateral flow immunoassay (LFIA) tailored for the precise detection of zearalenone, a mycotoxin with significant implications for human and animal health. A versatile and straightforward method for creating non-covalent magnetic labels is proposed and comprehensively compared with a covalent immobilization strategy. We employ the magnetic particle quantification (MPQ) technique for precise detection of the labels and characterization of their functionality, including measuring the antibody sorption density on the particle surface. Through kinetic studies using the label-free spectral phase interferometry, the rate and equilibrium constants for the binding of monoclonal antibodies with free (not bound with carrier protein) zearalenone were determined to be kon = 3.42 × 105 M−1s−1, koff = 7.05 × 10−4 s−1, and KD = 2.06 × 10−9 M. The proposed MPQ-LFIA method exhibits detection limits of 2.3 pg/mL and 7.6 pg/mL when employing magnetic labels based on covalent immobilization and non-covalent sorption, with dynamic ranges of 5.5 and 5 orders, correspondingly. We have successfully demonstrated the effective determination of zearalenone in barley flour samples contaminated with Fusarium graminearum. The ease of use and effectiveness of developed test systems further enhances their value as practical tools for addressing mycotoxin contamination challenges.
Zearalenone (ZEA) is a mycotoxin, a contaminant of agricultural products that has a negative effect on the immune system of both humans and animals. The kinetics of the interaction of conjugates of bovine serum albumin ZEA with monoclonal antibodies against ZEA and functionalized nanometers was characterized using a low-coherence interferometric setup. An ultra-sensitive approach has been developed for the determination of ZEA in food products at the place of demand based on characterized conjugates in combination with highly sensitive electronic registration of magnetic nanometers by nonlinear magnetization. Detection limits in $\mathrm{pg} / \mathrm{ml}$ units are achieved using covalently immobilized magnetic tags and are slightly higher with non-covalent antibody sorption.