Alexander Martin

Dr. Alexander Martin

Diagnostic and Interventional Radiology, University Hospital Zurich (USZ), Zürich, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in European Journal of Pharmaceutical Sciences
Verified
Journal Article
Closed access
JWJamie Wallis
Jamie Wallis
PKPrateek Katti
Prateek Katti
AMAlexander Martin
Alexander Martin
THTom Hills
Tom Hills
LSLeonard W. Seymour
Leonard W. Seymour
RCRobert Crispin Carlisle
Robert Crispin Carlisle

5 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
CPCatherine Mary Paverd
Catherine Mary Paverd
SKSivert Kupfer
Sivert Kupfer
IKIara Nascimento Kirchner
Iara Nascimento Kirchner
SNSherin Nambiar
Sherin Nambiar
AMAlexander Martin
Alexander Martin
LRLisa Ruby
Lisa Ruby
Objectives: Measurement location and patient state can impact noninvasive liver assessment and change clinical staging in ultrasound examinations. Research into differences exists for Shear Wave Speed (SWS) and Attenuation Imaging (ATI), but not for Shear Wave Dispersion (SWD). The aim of this study is to assess the effect of breathing phase, liver lobe, and prandial state on SWS, SWD, and ATI ultrasound measurements. Methods: Two experienced examiners performed SWS, SWD, and ATI measurements in 20 healthy volunteers using a Canon Aplio i800 system. Measurements were taken in the recommended condition (right lobe, following expiration, fasting state), as well as (a) following inspiration, (b) in the left lobe, and (c) in a nonfasting state. Results: SWS and SWD measurements were strongly correlated (r = 0.805, p < 0.001). Mean SWS was 1.34 ± 0.13 m/s in the recommended measurement position and did not change significantly under any condition. Mean SWD was 10.81 ± 2.05 m/s/kHz in the standard condition and significantly increased to 12.18 ± 1.41 m/s/kHz in the left lobe. Individual SWD measurements in the left lobe also had the highest average coefficient of variation (19.68%). No significant differences were found for ATI. Conclusion: Breathing and prandial state did not significantly affect SWS, SWD, and ATI values. SWS and SWD measurements were strongly correlated. SWD measurements in the left lobe showed a higher individual measurement variability. Interobserver agreement was moderate to good.

30 October 2017 in Safety
Verified
Journal Article
Open access
PDF file
AMAlexander Martin
Alexander Martin
AMAaron McConville
Aaron McConville
AMAaron McConville
Aaron McConville
AMAnna McLister
Anna McLister
James DavisJames Davis
James Davis
Transdermal microneedles have captured the attention of researchers in relation to a variety of applications, and silicone-based moulds required to produce these systems are now widely available and can be readily manufactured on the lab bench. There is however some concern over the potential for accidental needlestick injuries and, as with any sharp hazard, the potential for blood-borne pathogen transmission must be considered. This follows from recent governmental concerns over the use of microneedle systems in dermabrasion. Despite the piercing nature of the microneedle patch sharing many similarities with conventional hypodermic needles, there are notable factors that mitigate the risk of contamination. A range of microneedle systems has been prepared using micromoulding techniques, and their puncture capability assessed. A critical assessment of the potential for accidental puncture and the control measures needed to ensure safe utilisation of the patch systems is presented.

6 May 2023 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
AOAnika Obrist
Anika Obrist
LRLisa Ruby
Lisa Ruby
AMAlexander Martin
Alexander Martin
TFThomas Frauenfelder
Thomas Frauenfelder
MRMarga Rominger
Marga Rominger
CPCatherine Mary Paverd
Catherine Mary Paverd
The aim of the work described here was to investigate the relative contribution of confounding factors on liver shear wave speed (SWS) and shear wave dispersion slope (SWDS) measurements in three certified phantoms using a Canon Aplio clinical ultrasound scanner. A Canon Aplio i800 i-series ultrasound system (Canon Medical Systems Corporation, Otawara, Tochigi, Japan) with i8CX1 convex array (center frequency = 4 MHz) was used to examine dependencies caused by the depth, width and height of the acquisition box (AQB), the depth and size of the region of interest (ROI), the AQB angle and the pressure of the ultrasound probe on the surface of the phantom. Results revealed that depth is the most significant confounder in both SWS and SWDS measurements. AQB angle, height and width and ROI size exhibited minimal confounding effects on measurements. For SWS, the most consistent measurement depth is when the top of the AQB is placed between 2 and 4 cm, and the ROI is located between 3 and 7 cm deep. For SWDS, results indicate that measurement values significantly decrease with depth from the surface of the phantom until approximately 7 cm deep, and consequently no stable area of AQB placement or ROI depth exists. In contrast to SWS, the same ideal acquisition depth range cannot necessarily be applied to SWDS measurements because of a significant depth dependency.

9 September 2024 in Communications Engineering
Verified
Journal Article
Open access
PDF file
Carla FuenteslópezCarla Fuenteslópez
Carla Fuenteslópez
MGMichael Gray
Michael Gray
SBSimge Bahcevanci
Simge Bahcevanci
AMAlexander Martin
Alexander Martin
CSCameron A. B. Smith
Cameron A. B. Smith
Viorica PatruleaViorica Patrulea
Viorica Patrulea
Dimethylsulfoxide (DMSO) has conventionally been used for cell cryopreservation both in research and in clinical applications, but has long-term cytotoxic effects. Trehalose, a natural disaccharide, has been proposed as a non-toxic cryoprotectant. However, the lack of specific cell membrane transporter receptors inhibits transmembrane transport and severely limits its cryoprotective capability. This research presents a method to successfully deliver trehalose into mesenchymal stem cells (MSCs) using ultrasound in the presence of microbubbles. The optimised trehalose concentration was shown to be able to not only preserve membrane integrity and cell viability but also the multipotency of MSCs, which are essential for stem cell therapy. Confocal imaging revealed that rhodamine-labelled trehalose was transported into cells rather than simply attached to the membrane. Additionally, the membranes were successfully preserved in lyophilised cells. This study demonstrates that ultrasonication with microbubbles facilitated trehalose delivery, offering promising cryoprotective capability without the cytotoxicity associated with DMSO-based methods.

26 January 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
OHOlivia Hänni
Olivia Hänni
LRLisa Ruby
Lisa Ruby
CPCatherine Mary Paverd
Catherine Mary Paverd
Thomas FrauenfelderThomas Frauenfelder
Thomas Frauenfelder
MRMarga B. Rominger
Marga B. Rominger
AMAlexander Martin
Alexander Martin
There have been studies showing attenuation imaging (ATI) with ultrasound as an approach to diagnose liver diseases such as steatosis or cirrhosis. So far, this technique has only been used on a convex probe. The goal of the study was to investigate the feasibility of ATI measurements using the linear array on a canon Aplio i800 scanner on certified phantoms. Three certified liver tissue attenuation phantoms were measured in five different positions using a linear probe. The effects of positioning and depth were explored and compared. The values were compared to the certified expected value for each phantom as well as the different measurement values for each measurement position. The ATI measurements on phantoms showed significant effect for the different probe positions and region of interest (ROI) depths. Values taken in the center with the probe perpendicular to the phantom were closest to certified values. Median values at 2.5–4.5 cm depth for phantoms 1 and 2 and 0.5–2.5 cm for phantom 3 were comparable with certified values. Measurements taken at a depth greater than 6 cm in any position were the least representative of the certified values (p-value < 0.01) and had the widest range throughout the different sessions. ATI measurements can be performed with the linear probe in phantoms; however, careful consideration should be given to depth dependency, as it can significantly affect measurement values. Remaining measurements at various depths within the 0.5–6.0 cm range showed deviation from the certified values of approximately 25%.