Amit Vilas Sant

Dr. Amit Vilas Sant

Pandit Deendayal Petroleum University, Gandhinagar, India
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2022 in Clean Energy
Verified
Journal Article
Open access
PDF file
APArpitkumar J Patel
Arpitkumar J Patel
ASAmit Vilas Sant
Amit Vilas Sant
This paper proposes a cascaded low-pass filter (CLPF) scheme for the control of a unified power quality conditioner (UPQC) installed for enhancing the power quality of an electric vehicle (EV) charging station. With the incorporation of UPQC, the EV charging station draws sinusoidal currents at unity power factor and the supply voltage is maintained at the nominal value at the charger input. In the CLPF scheme, the α–β components of the load current are individually processed through a cascade connection of two LPFs to determine the corresponding fundamental orthogonal components. Based on thus determined components, the instantaneous and peak value and phase angle of the fundamental positive sequence component (FPSC) of the load current are computed. Similarly, the corresponding quantities related to the load and supply voltages are also computed with the CLPF scheme. With the computations related to the load current and supply voltage, the unit voltage templates (UVTs), power factor and fundamental active component (FAC) of the load current are calculated. For the control of shunt compensation, reference currents are generated based on the FAC of the load current and UVTs. Alternately, the control of series compensation is employed with the help of UVTs and peak amplitude of the FPSC of the load voltage. The performance of CLPF scheme-based extraction is compared with that of the earlier reported schemes through simulation and experimental studies. The performance comparison reveals a faster dynamic and more accurate steady-state response with the proposed scheme. The performance analysis of the proposed CLPF scheme-based control of a UPQC deployed at the EV charging station for different operating conditions demonstrates station operation with requisite reactive power compensation and mitigation of voltage sag/swell, and prevention of propagation of harmonic and unbalanced currents into the grid. This results in increased reliability of charger operation, energy savings and increased efficiency of the distribution network.

3 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
LSLeena Santosh
Leena Santosh
Brian AzzopardiBrian Azzopardi
Brian Azzopardi
ASAmit Vilas Sant
Amit Vilas Sant
PMPoonam Mishra
Poonam Mishra
Insular grids are fragile owing to lower inertia and the absence of interconnection with other grids. With the increasing penetration of non-dispatchable renewable energy sources, the vulnerability of such insular grids increases further. The government of India has proposed several projects to improve the photovoltaic systems (PV) penetration in the Andaman and Nicobar Islands’ grid. This paper investigates joint stochastic scheduling of energy and reserve generation for insular grids fed from diesel and gas-based generators, PV, and battery energy storage systems (BESS). The proposed stochastic scheduling model considers a wide range of probabilistic forecast scenarios instead of a deterministic model that assumes a single-point forecast. Hence, it provides an optimal solution that is technically feasible for a wide range of PV power forecast scenarios. The striking feature of the model developed in this work is the inclusion of stochastic constraints that represent (i) the coordination between PV and BESS, (ii) reserve constraints, (iii) battery charging/discharging limit constraints, and (iv) non-anticipatory constraints that ensure technical viability of scheduling decisions. The proposed model is validated on the dataset for South Andaman Island. Results reveal the applicability and feasibility of the proposed stochastic dispatch model for different generation mix scenarios.

5 January 2024 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
KPKashyap Patoliya
Kashyap Patoliya
ASAmit Vilas Sant
Amit Vilas Sant
APArpitkumar Patel
Arpitkumar Patel
ASAbhinav Sinha
Abhinav Sinha

28 June 2018 in Iranian Journal of Science and Technology, Transactions of Electrical Engineering
Verified
Journal Article
Closed access
PDF file
SJSiddharth Joshi
Siddharth Joshi
VPVivek Pandya
Vivek Pandya
ASAmit Vilas Sant
Amit Vilas Sant

3 January 2023 in International Journal of Ambient Energy
Verified
Journal Article
Closed access
PMPiyush B. Miyani
Piyush B. Miyani
ASAmit Vilas Sant
Amit Vilas Sant
This paper proposes lead compensator-based voltage control of a 3-phase quasi Z-source inverter (q-ZSI) integrating a solar PV system with the grid. Shoot-through control is incorporated in voltage-oriented control for regulating the dc-link voltage of q-ZSI. The lead compensator, which provides robust performance by shifting the pole pair to the right hand of the s-plane to ensure system stability, helps to determine the shoot-through duty ratio. The lead compensator is designed based on the bode diagram for the transfer function of the capacitor voltage to shoot through duty ratio with unity feedback gain. Additionally, using a lead compensator also results in simpler tuning requirements. The performance of 3-phase q-ZSI based grid-tied PV with lead compensator based dc-link voltage control is analysed under different operating conditions. The analysis reveals IEEE-1547 compliant operation with only active power being injected into the grid and dc-link voltage regulation..

18 January 2023 in International Journal of Ambient Energy
Verified
Journal Article
Closed access
OSOjaswini A. Sharma
Ojaswini A. Sharma
ASAmit Vilas Sant
Amit Vilas Sant
Increasing energy demand and the need for reduction in carbon emissions has necessitated the grid integration of solar photovoltaic (PV) systems, which are being widely employed in the tropical region. In a single-stage PV system, a voltage source inverter (VSI) is used to interface the PV panels with the grid. For the control and grid synchronization of this VSI, an instantaneous phase angle of the fundamental positive sequence component (FPS) of grid voltage needs to be determined. Generalized integrator-based phase-locked loops (PLLs) are widely employed for this determination. This paper proposes a new orthogonal signal generator (OSG) for a generalized integrator-based PLL, known as mixed third-fourth order generalized integrator-based PLL (MTFOGI-PLL). The proposed MTFOGI offers fast dynamic response, better filtering and dc-offset rejection capability. The reported PLL is implemented as a part of the voltage-oriented control of the grid-tied PV system. The MTFOGI-PLL based operation of the grid-tied PV system is analyzed under ideal and non-ideal grid conditions. From the results, it is observed that the proposed PLL accurately extracts the FPS voltages under different operating conditions resulting in the functioning of the grid-tied PV system as per the grid codes.