Andreja Carek

Prof. Dr. Andreja Carek

School of Dental Medicine, University of Zagreb, Zagreb, Zagreb, Grad, Croatia
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2022 in Polymers
Verified
Journal Article
Open access
ACAndreja Carek
Andreja Carek
KDKsenija Dukaric
Ksenija Dukaric
HMHelena Miler
Helena Miler
Danijela MarovićDanijela Marović
Danijela Marović
ZTZrinka Tarle
Zrinka Tarle
Matej ParMatej Par
Matej Par
This study investigated the effect of different curing conditions on the degree of conversion and mechanical properties of contemporary dual-curing resin cements. The material specimens were either light-cured directly, light-cured through a 1-mm lithium disilicate glass-ceramic layer, or self-cured. The degree of conversion was measured in 0.1-mm films using Fourier-transform infrared spectroscopy 1 day, 7 days, and 28 days post-cure. Specimens used to study the flexural strength and modulus were prepared according to the ISO 4049 protocol, stored for 28 days post-cure, and subjected to accelerated aging by absolute ethanol immersion. The degree of conversion values ranged between 44.3–77.8%. Flexural strength varied between 11.4–111.1 MPa, while flexural modulus amounted to 0.7–5.5 GPa. The degree of conversion was significantly affected by material type, curing conditions, and post-cure time; however, variations in curing conditions were the least influential factor. A statistically significant effect of curing conditions on the degree of conversion was identified for only one of the five materials tested, whereas the flexural strength and modulus of all tested materials were significantly reduced in the experimental groups that were light-cured through a ceramic layer or self-cured. The effect size analysis showed that mechanical properties were most affected by the material type, while the differences in curing conditions were less influential. A comparison of the degree of conversion and mechanical properties indicated that different curing conditions may lead to significantly different flexural strength and modulus, which are not necessarily accompanied by identifiable variations in the degree of conversion.

27 December 2022 in Materials
Verified
Journal Article
Open access
PDF file
ACAndreja Carek
Andreja Carek
LBLjerka Slokar Benić
Ljerka Slokar Benić
DKDaniel Komar
Daniel Komar
EKEna Krebelj
Ena Krebelj
Lithium disilicate and zirconia are the two most popular materials for aesthetic and dental prosthetic work; however, due to their limitations, a new material is being researched, namely zirconia-reinforced lithium disilicate, the surface of which is treated with different procedures to achieve the best possible surface properties. In this study, the surface of zirconia-reinforced lithium disilicate glass-ceramic was treated using different methods (conventional and laser) to determine the effects of the treatment procedures on the surface properties and surface roughness to achieve a higher strength of adhesion from the self-adhesive resin cement to zirconia-reinforced lithium disilicate. The treated surfaces were investigated using profilometry, X-ray diffraction and energy dispersive X-ray fluorescence. The results obtained were statistically evaluated. The results show that the surface roughness is highest for the samples treated with Er:YAG (erbium-doped yttrium aluminium garnet laser) and silanisation. Furthermore, the surface treatment procedures applied did not change the composition of the surface.

15 September 2021 in Acta Stomatologica Croatica
Verified
Journal Article
Open access
DKDaniel Komar
Daniel Komar
IBIvona Bago
Ivona Bago
DVDubravka Negovetic Vranic
Dubravka Negovetic Vranic
JKJosip Kranjčić
Josip Kranjčić
BBBruna Brkić
Bruna Brkić
ACAndreja Carek
Andreja Carek
Aim: To analyze the influence of different surface pretreatments of zirconium dioxide reinforced lithium disilicate ceramics on the shear bond strength of self-adhesive resin cement. Materials and methods: Eighty-four zirconium reinforced lithium disilicate disc Vita suprinity (Vita Zahnfabrick, Bad Sackingen, Germany) 14x12x2 mm specimens were fabricated according to the manufacturer's recommendations. The specimens were embedded in acrylic resin blocks and randomly divided in seven groups (n=12/each) accorrding to the treatment: Group 1- 10% hydrofluoric acid; Group 2- sitane; Group 3- hydrofluoric and sitane; Group 4- sandblasting with silane; Group 5- Er: YAG laser+ silane; Group 6- Nd: YAG laser + silane; and the control group, in which the specimens were not treated. Round shape composite discs (Filtek Butk fill, 3M ESPE, St.Paul, Minnesota, USA) with 3.5 mm diameter, were made for shear bond strength testing, and then cemented to the ceramic sample surface using composite cement (RelyX U200 Automix, 3M ESPE, Neuss, Germany). After cementing the composite disc on the sample, the samples were subjected to shear bond strength test of 10 N with a "stress rate" of 1 MPa / s. To determine the nature of the fracture (adhesive, cohesive or adhesivecohesive), the broken samples were examined under a stereomicroscope. The ANOVA test and the Tukey test were used to compare the values of the bond strength characteristics between different types of materials. AU tests were performed with a significance level of alpha = 0.05. Results: There was a significant difference in the shear bond strength of self-adhesive cement to dental lithium-disilicate ceramics reinforced with zirconium dioxide after different preparation protocols (p <0.05). The treatment of lithium disilicate ceramics reinforced with zirconium dioxide by silanization, sandblasting + silanization, Nd: YAG + silanization resulted in significantly higher bond strength compared to the control group. There was statistically higher bond strength of self-adhesive cement after pretreatment of lithium disilicate ceramics Nd: YAG + silanization compared to Er: YAG + silanization (p <0.05). Adhesive fracture dominated in the control group, sandblasting + silanization group, and in the laser groups, white mixed fracture dominated in other groups. Conclusion: Under the limitations of this study, the Nd:YAG irradiation with silanization could be used as pretreatment for providing greater shear bond strength of self-adhesive resin cement to zirconium reinforced lithium disilicate.

26 April 2023 in Materials
Verified
Journal Article
Open access
PDF file
ACAndreja Carek
Andreja Carek
LBLjerka Slokar Benić
Ljerka Slokar Benić
VBVATROSLAV BUBALO
VATROSLAV BUBALO
Cobalt–chromium alloys (Co-Cr) are widely used in dentistry due to their excellent mechanical properties and corrosion resistance. Since prosthetic materials must be permanently stable in the oral cavity, it is very important to determine the release of ions from alloys in the oral cavity. In dentistry today, metals and alloys are mainly joined by laser and tungsten inert gas (TIG) welding. Therefore, in this work, the release of metal ions from six different Co-Cr alloys joined by these two welding methods was quantified to determine the effects of the welding method on an ion release. Static immersion tests, atomic absorption spectrometry and statistical analysis were performed for this purpose. The results showed that laser-welded alloys release a lower amount of metal ions compared to TIG-welded alloys.

29 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JŠJadranka Šanjug
Jadranka Šanjug
KKKrunoslav Kuna
Krunoslav Kuna
MGMarina Sprem Goldstajn
Marina Sprem Goldstajn
LDLidija Fumić Dunkić
Lidija Fumić Dunkić
ACAndreja Carek
Andreja Carek
DVDubravka Negovetic Vranic
Dubravka Negovetic Vranic
Background: The COMT gene polymorphism is associated with neurological and psychiatric disorders and pain perception. The present study investigates the existence of anxiety and pain perception in relation to the COMT (catechol-O-methyltransferase) gene polymorphism in labouring women (during “natural” childbirth) with or without inhaled analgesia. Methods: A total of 181 women who chose vaginal birth were enrolled in this study. To present the difference in pain perception, the parturients were divided into one group (n = 90) that chose labour analgesia with inhaled nitrous oxide (50% nitrous oxide and 50% oxygen) and one group (n = 91) without analgesia. The blood samples were taken during the pregnancy as a part of routine pregnancy controls in the hospital. The COMT gene polymorphism was detected with the PCR technique. The pain perception of parturients was self-evaluated two times according to the VAS (Visual Analogue Scale), and anxiety as a personality trait was determined with the STAI-T (State Trait Anxiety Inventory). Pain perception as well as anxiety were compared according to COMT genotypes. Results: In the 181 pregnant women, there were 40 women (22%) of wild homozygotes (GG) of COMT, 95 women (53%) of mutant heterozygotes (GA), and 46 women (25%) of mutant homozygotes (AA). A negative association of pain perception with the GA (mutant heterozygote) polymorphism of the COMT gene versus the wild-type (GG polymorphism) was observed. The GA polymorphism of the COMT gene was associated with 0.46 units lower pain perception compared to the wild type (GG). The anxiety trait score in group AA was lower than in groups GA and GG. The difference reached statistical significance only when comparing AA versus GA (p > 0.042). Analgesic efficacy of nitrous oxide was noticed in 22% of labouring women who reported moderate pain (VAS score 4–7). Conclusions: The COMT gene polymorphism was associated with pain perception and anxiety among parturients. The COMT gene polymorphism GA was associated with negative pain perception among labouring women. Nitrous oxide showed statistical significance in anxiolytic efficacy during labour in women with mild anxiety as a personality trait. Anxiolytic efficacy of nitrous oxide has shown better efficacy in parturients with the COMT gene polymorphism AA.

27 June 2024 in Materials
Verified
Journal Article
Open access
PDF file
KBKatarina Bauer
Katarina Bauer
ACAndreja Carek
Andreja Carek
LBLjerka Slokar Benić
Ljerka Slokar Benić
Tomislav BadelTomislav Badel
Tomislav Badel
Dental technology has developed materials for prosthetics that are very similar to natural teeth and offer a good balance between durability and esthetics; however, some of these materials are not very color-stable under the influence of external factors. Therefore, the aim of this study is to determine and compare the color change (∆E00) of different esthetic monolithic monochromatic CAD/CAM materials after they have been thermocycled and treated with staining solutions. The color parameters were determined using a spectrophotometer on a white and black background. Five CAD/CAM materials were used for this study—CAD/CAM nanoceramic (GC Cerasmart270), CAD/CAM lithium disilicate ceramic (IPS e.max CAD), CAD/CAM polymer (Telio CAD), CAD/CAM composite (Tetric CAD) and CAD/CAM polymer-infiltrated ceramic (Vita Enamic). The test specimens produced were divided into groups and were thermocycled in distilled water. They were then stored for four weeks at 37 °C in either distilled water as a control liquid, black tea, instant coffee or red wine. The aim is also to evaluate the color changes as a function of the exposure time of the staining solutions. The results obtained were analyzed statistically. All CAD/CAM materials tend to discolor to varying degrees. Among the factors contributing to discoloration, red wine proved to be the most significant influencing factor. The conclusion from the results is that the color change is influenced by the type of material, the staining solution, the sample thickness, the color background and the aging time.