Danijela Marović

Prof. Dr. Danijela Marović

School of Dental Medicine, University of Zagreb, Zagreb, Zagreb, Grad, Croatia
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2014 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
ZTZrinka Tarle
Zrinka Tarle
TAThomas Attin
Thomas Attin
Danijela MarovićDanijela Marović
Danijela Marović
LAL. Andermatt
L. Andermatt
MRM. Ristic
M. Ristic
TTT. T. Tauböck
T. T. Tauböck

1 November 2015 in Journal of Dentistry
Verified
Journal Article
Open access
Tobias TauböckTobias Tauböck
Tobias Tauböck
ZTZrinka Tarle
Zrinka Tarle
Danijela MarovićDanijela Marović
Danijela Marović
TAThomas Attin
Thomas Attin
To investigate the influence of pre-heating of high-viscosity bulk-fill composite materials on their degree of conversion and shrinkage force formation. Four bulk-fill composite materials (Tetric EvoCeram Bulk Fill-TECBF, x-tra fil-XF, QuixFil-QF, SonicFill-SF) and one conventional nano-hybrid resin composite (Tetric EvoCeram-TEC) were used. The test materials were either kept at room temperature or pre-heated to 68°C by means of a commercial heating device, before being photoactivated with a LED curing unit for 20s at 1170mW/cm(2). Shrinkage forces (n=5) of 1.5-mm-thick specimens were recorded in real-time for 15min inside a temperature-controlled chamber at 25°C (simulating intraoral temperature after rubber dam application) with a custom-made stress analyzer. Degree of conversion (n=5) was determined at the bottom of equally thick (1.5mm) specimens using Fourier transform infrared spectroscopy. Data were analyzed with Student's t-test, ANOVA and Tukey's HSD post-hoc test (α=0.05). Composite pre-heating significantly increased the degree of conversion of TECBF, but had no effect on monomer conversion of the other materials investigated. For each of the test materials, pre-heated composite generated significantly lower shrinkage forces than room-temperature composite. At both temperature levels, TECBF created the significantly highest shrinkage forces, and QF caused significantly higher shrinkage forces than both XF and TEC. Both the composite material and the pre-cure temperature affect shrinkage force formation. Pre-heating of bulk-fill and conventional restorative composites prior to photoactivation decreases polymerization-induced shrinkage forces without compromising the degree of conversion. Composite pre-heating significantly reduces shrinkage force formation of high-viscosity bulk-fill and conventional resin composites, while maintaining or increasing the degree of monomer conversion, dependent upon the specific composite material used.

1 May 2015 in Operative Dentistry
Verified
Journal Article
Closed access
MPM Par
M Par
OGO Gamulin
O Gamulin
Danijela MarovićDanijela Marović
Danijela Marović
EKE Klaric
E Klaric
ZTZrinka Tarle
Zrinka Tarle
SUMMARY: Objective: The aim of this study was to determine degree of conversion (DC) of solid and flowable bulk-fill composites immediately and after 24 hours and investigate the variations of DC at surface and depths up to 4 mm.Materials and Methods: Eight bulk-fill composites (Tetric EvoCeram Bulk Fill [shades IVA and IVB], Quixfil, X-tra fil, Venus Bulk Fill, X-tra Base, SDR, Filtek Bulk Fill) were investigated, and two conventional composites (GrandioSO, X-Flow) were used as controls. The samples (n = 5) were cured for 20 seconds with irradiance of 1090 mW/cm2. Raman spectroscopic measurements were made immediately after curing on sample surfaces and after 24 hours of dark storage at surface and at incremental depths up to 4 mm. Mean DC values were compared using repeated measures analysis of variance (ANOVA) and t-test for dependent samples.Results: Surface DC values immediately after curing ranged from 59.1%-71.8%, while the 24-hour postcure values ranged from 71.3%-86.1%. A significant increase of DC was observed 24 hours post cure for all bulk-fill composites, which amounted from 11.3% to 16.9%. Decrease of DC through depths up to 4 mm varied widely among bulk-fill composites and ranged from 2.9% to 19.7%.Conclusions: All bulk-fill composites presented a considerable 24-hour postcure DC increase and clinically acceptable DC at depths up to 4 mm. Conventional control composites were sufficiently cured only up to 2 mm, despite significant postcure polymerization.

Verified
Journal Article
Open access
PDF file
Håvard Jostein HaugenHåvard Jostein Haugen
Håvard Jostein Haugen
Danijela MarovićDanijela Marović
Danijela Marović
Matej ParMatej Par
Matej Par
MTMinh Khai Le Thieu
Minh Khai Le Thieu
JRJanne Reseland
Janne Reseland
GJGaute Floer Johnsen
Gaute Floer Johnsen
The aim of the study was to perform comprehensive characterization of two commonly used bulk fill composite materials (SDR Flow (SDR) and Filtek™ Bulk Fill Flowable Restorative (FBF) and one conventional composite material (Tetric EvoCeram; TEC). Eleven parameters were examined: flexural strength (FS), flexural modulus (FM), degree of conversion, depth of cure, polymerisation shrinkage (PS), filler particle morphology, filler mass fraction, Vickers hardness, surface roughness following simulated toothbrush abrasion, monomer elution, and cytotoxic reaction of human gingival fibroblasts, osteoblasts, and cancer cells. The degree of conversion and depth of cure were the highest for SDR, followed by FBF and TEC, but there was no difference in PS between them. FS was higher for bulk fill materials, while their FM and hardness were lower than those of TEC. Surface roughness decreased in the order TEC→SDR→FBF. Bisphenol A-glycidyl methacrylate (BisGMA) and urethane dimethacrylate were found in TEC and FBF eluates, while SDR released BisGMA and triethylene glycol dimethacrylate. Conditioned media accumulated for 24 h from FBF and TEC were cytotoxic to primary human osteoblasts. Compared to the conventional composite, the tested bulk fill materials performed equally or better in most of the tests, except for their hardness, elastic modulus, and biocompatibility with osteoblasts.

22 December 2014 in Acta Odontologica Scandinavica
Verified
Journal Article
Closed access
PDF file
Danijela MarovićDanijela Marović
Danijela Marović
TTTobias T. Tauböck
Tobias T. Tauböck
TAThomas Attin
Thomas Attin
VPVlatko Panduric
Vlatko Panduric
ZTZrinka Tarle
Zrinka Tarle
Objective. To investigate the subsurface degree of conversion (DC) and shrinkage force formation of low-viscosity (flowable) bulk-fill composite materials. Materials and methods. Three flowable bulk-fill resin composites [SureFil SDR flow (SDR; Dentsply DeTrey), Venus Bulk Fill (VB; Heraeus Kulzer) and x-tra base (XB; VOCO)] and one conventional flowable control composite material [EsthetX flow (EX; Dentsply DeTrey)] were tested. The materials were photoactivated for 20 s at an irradiance of 1170 mW/cm2 and the DC (n = 5) was recorded at 0.1-, 1.5- and 4-mm depth using Fourier transform infrared spectroscopy. Shrinkage forces (n = 5) of 1.5-mm-thick specimens were continuously recorded for 15 min using a custom-made stress analyzer. Data were statistically analyzed by ANOVA, Tukey’s HSD and Bonferroni’s post-hoc tests (α = 0.05). Results. SDR generated the significantly lowest shrinkage forces (22.9 ± 1.4 N), but also attained the significantly lowest DC at 1.5-mm depth (67.5 ± 0.8%). The conventional flowable composite EX generated the significantly highest shrinkage forces (40.7 ± 0.7 N) and reached a significantly higher DC (74.4 ± 1.3%) compared to SDR and XB at 1.5-mm depth. The shrinkage force values of VB (29.4 ± 1.1 N) and XB (28.3 ± 0.6 N) were similar (p > 0.05). All materials attained significantly higher DC at 4-mm depth than at the near-surface. Conclusion. The tested low-viscosity bulk-fill materials show lower shrinkage force formation than a conventional flowable resin composite at high levels of degree of conversion up to 4-mm incremental thickness.

1 October 2014 in Journal of Dentistry
Verified
Journal Article
Closed access
Matej ParMatej Par
Matej Par
OGOzren Gamulin
Ozren Gamulin
Danijela MarovićDanijela Marović
Danijela Marović
EKEva Klarić
Eva Klarić
ZTZrinka Tarle
Zrinka Tarle