Angamuthu Ananth

Dr. Angamuthu Ananth

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2025 in Machines
Verified
Journal Article
Open access
PDF file
SPsivakumar palaniswamy
sivakumar palaniswamy
VEVENUGOPAL - E
VENUGOPAL - E
AMAnand Mouttouvelou
Anand Mouttouvelou
AAAngamuthu Ananth
Angamuthu Ananth
The International Energy Agency (IEA) asserts that worldwide electricity demand is rising exponentially every year. Energy storage is the cornerstone of electricity demand. Gravity-based energy storage systems represent the optimum alternative for energy storage systems. They offer zero carbon emission, environmental sustainability, cost-effectiveness, geographical flexibility, long-duration storage, and scalability ranging from 0.5 to 10 GWh. This research introduces a novel design to confirm the workability of the gravity energy storage model. It validates the feasibility of the system through the drive train setup. The drive train model involves storing potential energy by elevating the stack weight using solar photovoltaic input and releasing the weight to generate electrical energy using the gravitational field. The gravity motion is theoretically proven by the mathematical analysis, drive train control system transfer function model, and golden ratio-based design. Solidworks simulation model enhances the working of the drive train setup. Through hardware iterative experimental results with different load profiles, validate the performance metrics. The gravity energy storage system’s feasibility is demonstrated by its scalability in comparison with battery energy systems. Gravity-based energy storage is the best option for utility-scale renewable energy grid integration, since it has a low energy density, medium and large capacity, long-lasting storage, and high scalability.

10 January 2022 in Journal of Power Electronics
Verified
Journal Article
Closed access
PDF file
AAAngamuthu Ananth
Angamuthu Ananth
MSM. Sundaram
M. Sundaram
VBV. Balaji
V. Balaji

31 May 2026 in Electricity
Verified
Journal Article
Open access
PDF file
AAAngamuthu Ananth
Angamuthu Ananth
SMSundaram Maruthachalam
Sundaram Maruthachalam
AMAnand Mouttouvelou
Anand Mouttouvelou
SPsivakumar palaniswamy
sivakumar palaniswamy
The adoption of solar photovoltaic (PV) inverters in residential networks has increased significantly because of the growing demand for clean energy and carbon footprint reduction. While these systems enable utilities to reduce dependence on conventional energy sources, several operational challenges remain unaddressed at the prosumer level, including power factor (PF) penalties, voltage fluctuations, and underutilization of inverter capacity. Most commercially available residential inverters primarily focus on real power export and do not actively manage reactive power, leading to power quality issues in low-voltage distribution networks. In addition, emerging time-of-day (ToD) tariff structures are not effectively utilized by existing control strategies. In this work, an optimization-based supervisory control strategy is proposed for residential PV inverters. The problem is formulated as a convex quadratic programming (CQP) problem, where real and reactive power are optimally coordinated under inverter kilovolt-ampere constraints. The objective is to integrate ToD-based economic optimization with power factor regulation. Unlike conventional approaches that enforce strict PF constraints, the proposed method incorporates PF through a quadratic penalty on the deviation from the desired active–reactive power relationship, enabling a controlled trade-off between economic benefit and grid-support requirements. Depending on operating conditions, the controller dynamically prioritizes real power export or reactive power support while maintaining PF close to the desired threshold. Experimental validation is carried out on a 6 kVA hardware prototype. The results demonstrate improved inverter utilization, enhanced power factor performance, and significant cost reduction under the considered operating scenario. These findings highlight the potential of coordinated real and reactive power management for improving both economic and grid performance in residential PV systems.

1 October 2026 in IEEE Embedded Systems Letters
Verified
Journal Article
Closed access
AAAngamuthu Ananth
Angamuthu Ananth
SPsivakumar palaniswamy
sivakumar palaniswamy
MAM. Anand
M. Anand
AVA. Viswanath
A. Viswanath
The work presented in this paper proposes a real-time and resource-efficient framework for Total Harmonic Distortion (THD) estimation using compressed sampling. The proposed method reconstructs the signal content from sub-Nyquist samples, by exploiting the sparsity concept in the harmonic-rich signal in the frequency domain. This eliminates the conventional method of high sampling rate. The experimentation on the TI’s C2000 Digital Signal Controller (DSC) shows close agreement with reference measurements from a standard Power Quality (PQ) meters, thereby confirming the accuracy and reliability of the approach. The reduction in data volume also highlights the potential of the proposed method for low-bandwidth power quality monitoring in cloud-connected systems. In addition, the proposed compressed-sampling framework enables the edge device to transmit only a very small subset of data to the cloud, rather than streaming full-resolution waveforms. These compact measurement packets are sufficient for accurate waveform reconstruction and THD evaluation on demand, making the approach highly suitable for large-scale smart-metering, solar-farm monitoring, and other bandwidth-constrained applications.