Anooshe Mirhakimi

Mrs. Anooshe Mirhakimi


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Devashish DubeyDevashish Dubey
Devashish Dubey
AMAnooshe Mirhakimi
Anooshe Mirhakimi
Mohamed ElbestawiMohamed Elbestawi
Mohamed Elbestawi
Most materials conventionally found in nature expand with an increase in temperature. In actual systems and assemblies like precision instruments, this can cause thermal distortions which can be difficult to handle. Materials with a tendency to shrink with an increase in temperature can be used alongside conventional materials to restrict the overall dimensional change of structures. Such structures, also called negative-thermal-expansion materials, could be crucial in applications like electronics, biomedicine, aerospace components, etc., which undergo high changes in temperature. This can be achieved using mechanically engineered materials, also called negative thermal expansion (NTE) mechanical metamaterials. Mechanical metamaterials are mechanically architected materials with novel properties that are rare in naturally occurring materials. NTE metamaterials utilize their artificially engineered architecture to attain the rare property of negative thermal expansion. The emergence of additive manufacturing has enabled the feasible production of their intricate architectures. Industrial processes such as laser powder bed fusion and direct energy deposition, both utilized in metal additive manufacturing, have proven successful in creating complex structures like lattice formations and multimaterial components in the industrial sector, rendering them suitable for manufacturing NTE structures. Nevertheless, this review examines a range of fabrication methods, encompassing both additive and traditional techniques, and explores the diverse materials used in the process. Despite NTE metamaterials being a prominent field of research, a comprehensive review of these architected materials is missing in the literature. This article aims to bridge this gap by providing a state-of-the-art review of these metamaterials, encompassing their design, fabrication, and cutting-edge applications.

13 February 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
MRMansoureh Rezapourianghahfarokhi
Mansoureh Rezapourianghahfarokhi
AMAnooshe Mirhakimi
Anooshe Mirhakimi
Tatevik MinasyanTatevik Minasyan
Tatevik Minasyan
MNMahan Nematollahi
Mahan Nematollahi
Irina HussainovaIrina Hussainova
Irina Hussainova
Patient-specific lattice implants (PSLIs) and modular porous scaffolds have emerged as promising solutions for treating diaphyseal segmental defects of the femur and tibia, particularly where conventional reconstruction methods fall short. This second part of our two-part review focuses on how current studies transform computed tomography (CT) and μCT datasets into architected lattice implants, as well as how these constructs are fabricated and numerically, mechanically, biologically, and clinically verified. We outline imaging pipelines, including Digital Imaging and Communications in Medicine (DICOM) acquisition, segmentation, contralateral mirroring, and Hounsfield Units (HU)–density–elasticity mapping, and show how these choices impact finite element (FE) models and print-ready geometries. Next, lattice design strategies and mixed-material concepts are compared and linked to specific additive manufacturing routes in metals, polymers, and bioceramics, such as laser powder bed fusion (LPBF), electron beam melting (EBM), fused deposition modeling (FDM), material jetting, and extrusion-based bioprinting. Methodological overviews of linear–elastic models and homogenized finite element (FE) models, along with bench-top mechanical tests, in vitro cell assays, in vivo animal studies, and early clinical series, are utilized to categorize the studies into four pathways: simulation (S), mechanical (E_mech), biological (E_bio), and validation (V). Based on the reviewed literature, we establish a general workflow for CT implants. We identify common gaps in the process, observe insufficient reporting of imaging and modeling details, note a lack of data on fatigue and remodeling, and recognize the limited size of clinical cohorts. Additionally, we provide practical recommendations for developing more standardized and scalable planning pipelines. Part 1 of this two-part review studied defect patterns, anatomical location, and fixation strategies for patient-specific lattice implants used in femoral and tibial segmental reconstruction, with emphasis on how defect morphology and subregional anatomy influence construct selection and mechanical behavior. It established a defect- and fixation-centered review that provides the clinical and anatomical context for the workflow and validation analysis presented in Part 2.

10 February 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
MRMansoureh Rezapourianghahfarokhi
Mansoureh Rezapourianghahfarokhi
AMAnooshe Mirhakimi
Anooshe Mirhakimi
MNMahan Nematollahi
Mahan Nematollahi
Tatevik MinasyanTatevik Minasyan
Tatevik Minasyan
Irina HussainovaIrina Hussainova
Irina Hussainova
This first part of a two-part review examines how Computed Tomography(CT)-based, additively manufactured (AM) porous implants are used to reconstruct large segmental defects of the femur and tibia. We focus on lightweight patient-specific lattice implants, architected cages, and modular porous constructs that incorporate engineered porosity into the load-bearing structure and are deployed with plate-, nail-, or external-fixator-based stabilization. We show how defects are described and classified by size, morphology, and anatomical subsegment; how these descriptors influence fixation choice and the resulting mechanical environment; and where along the femur and tibia porous implants have been applied in clinical and preclinical settings. Across the literature, outcomes appear to depend most strongly on defect morphology and local biology, while fixation feasibility and construct behavior vary by subregional anatomy. Most reported constructs use Ti6Al4V porous architectures intended to share load with fixation, reduce stress shielding, and provide a regenerative space for graft and tissue ingrowth. Finite element analyses (FEA) and bench-top studies consistently indicate that lattice architecture, relative density (RD), and fixation concept jointly control stiffness, micromotion, and fatigue-sensitive regions, whereas early animal and human reports describe promising incorporation and functional recovery in selected cases. However, defect descriptors, fixation reporting, boundary conditions, and outcome metrics remain diverse, and explicit quantitative validation of simulations against mechanical or in vivo measurements is uncommon. Most published work relies on simulation and bench testing, with limited reporting of biological endpoints, leaving a validation gap that prevents direct translation. We emphasize the need for standardized defect and fixation descriptors, harmonized mechanical and modeling protocols, and defect-centered datasets that integrate anatomy, mechanics, and longitudinal outcomes. Across the 27 included studies (may be counted in more than one group), simulation and mechanical testing are reported in 19/27 (70%) and 15/27 (56%), respectively, while in vivo studies (preclinical or clinical) account for 9/27 (33%), highlighting a validation gap that limits translation. Part 2 (under review); of these two series review paper; Patient-Specific Lattice Implants for Segmental Femoral and Tibial Reconstruction (Part 2): CT-Based Personalization, Design Workflows, and Validation-A Review; extends this work by detailing CT-to-implant workflows, lattice design strategies, and methodological validation.