Mahan Nematollahi

Mr. Mahan Nematollahi

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
MRMansoureh Rezapourianghahfarokhi
Mansoureh Rezapourianghahfarokhi
AMAnooshe Mirhakimi
Anooshe Mirhakimi
Tatevik MinasyanTatevik Minasyan
Tatevik Minasyan
MNMahan Nematollahi
Mahan Nematollahi
Irina HussainovaIrina Hussainova
Irina Hussainova
Patient-specific lattice implants (PSLIs) and modular porous scaffolds have emerged as promising solutions for treating diaphyseal segmental defects of the femur and tibia, particularly where conventional reconstruction methods fall short. This second part of our two-part review focuses on how current studies transform computed tomography (CT) and μCT datasets into architected lattice implants, as well as how these constructs are fabricated and numerically, mechanically, biologically, and clinically verified. We outline imaging pipelines, including Digital Imaging and Communications in Medicine (DICOM) acquisition, segmentation, contralateral mirroring, and Hounsfield Units (HU)–density–elasticity mapping, and show how these choices impact finite element (FE) models and print-ready geometries. Next, lattice design strategies and mixed-material concepts are compared and linked to specific additive manufacturing routes in metals, polymers, and bioceramics, such as laser powder bed fusion (LPBF), electron beam melting (EBM), fused deposition modeling (FDM), material jetting, and extrusion-based bioprinting. Methodological overviews of linear–elastic models and homogenized finite element (FE) models, along with bench-top mechanical tests, in vitro cell assays, in vivo animal studies, and early clinical series, are utilized to categorize the studies into four pathways: simulation (S), mechanical (E_mech), biological (E_bio), and validation (V). Based on the reviewed literature, we establish a general workflow for CT implants. We identify common gaps in the process, observe insufficient reporting of imaging and modeling details, note a lack of data on fatigue and remodeling, and recognize the limited size of clinical cohorts. Additionally, we provide practical recommendations for developing more standardized and scalable planning pipelines. Part 1 of this two-part review studied defect patterns, anatomical location, and fixation strategies for patient-specific lattice implants used in femoral and tibial segmental reconstruction, with emphasis on how defect morphology and subregional anatomy influence construct selection and mechanical behavior. It established a defect- and fixation-centered review that provides the clinical and anatomical context for the workflow and validation analysis presented in Part 2.

10 February 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
MRMansoureh Rezapourianghahfarokhi
Mansoureh Rezapourianghahfarokhi
AMAnooshe Mirhakimi
Anooshe Mirhakimi
MNMahan Nematollahi
Mahan Nematollahi
Tatevik MinasyanTatevik Minasyan
Tatevik Minasyan
Irina HussainovaIrina Hussainova
Irina Hussainova
This first part of a two-part review examines how Computed Tomography(CT)-based, additively manufactured (AM) porous implants are used to reconstruct large segmental defects of the femur and tibia. We focus on lightweight patient-specific lattice implants, architected cages, and modular porous constructs that incorporate engineered porosity into the load-bearing structure and are deployed with plate-, nail-, or external-fixator-based stabilization. We show how defects are described and classified by size, morphology, and anatomical subsegment; how these descriptors influence fixation choice and the resulting mechanical environment; and where along the femur and tibia porous implants have been applied in clinical and preclinical settings. Across the literature, outcomes appear to depend most strongly on defect morphology and local biology, while fixation feasibility and construct behavior vary by subregional anatomy. Most reported constructs use Ti6Al4V porous architectures intended to share load with fixation, reduce stress shielding, and provide a regenerative space for graft and tissue ingrowth. Finite element analyses (FEA) and bench-top studies consistently indicate that lattice architecture, relative density (RD), and fixation concept jointly control stiffness, micromotion, and fatigue-sensitive regions, whereas early animal and human reports describe promising incorporation and functional recovery in selected cases. However, defect descriptors, fixation reporting, boundary conditions, and outcome metrics remain diverse, and explicit quantitative validation of simulations against mechanical or in vivo measurements is uncommon. Most published work relies on simulation and bench testing, with limited reporting of biological endpoints, leaving a validation gap that prevents direct translation. We emphasize the need for standardized defect and fixation descriptors, harmonized mechanical and modeling protocols, and defect-centered datasets that integrate anatomy, mechanics, and longitudinal outcomes. Across the 27 included studies (may be counted in more than one group), simulation and mechanical testing are reported in 19/27 (70%) and 15/27 (56%), respectively, while in vivo studies (preclinical or clinical) account for 9/27 (33%), highlighting a validation gap that limits translation. Part 2 (under review); of these two series review paper; Patient-Specific Lattice Implants for Segmental Femoral and Tibial Reconstruction (Part 2): CT-Based Personalization, Design Workflows, and Validation-A Review; extends this work by detailing CT-to-implant workflows, lattice design strategies, and methodological validation.

9 July 2026 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
MNMahan Nematollahi
Mahan Nematollahi
AEAmir Esrafilian
Amir Esrafilian
JLJere Lavikainen
Jere Lavikainen
Mika MononenMika Mononen
Mika Mononen
LSLauri Stenroth
Lauri Stenroth
RKRami K. Korhonen
Rami K. Korhonen
Low-fidelity, artificial intelligence (AI)-generated approaches are increasingly used to estimate kinematics and kinetics of human movement, which are traditionally measured by high-fidelity motion capture (Mocap) approaches. However, there are no methods to study knee joint tissue mechanics using such low-fidelity approaches. To do so, we investigated knee cartilage stresses and strains using finite element (FE) models driven by both high- and low-fidelity motion capture methods. We performed subject-specific FE modeling on nine healthy participants to evaluate tissue mechanical responses by two different approaches. High-fidelity kinematic and kinetic data were obtained through motion capture and musculoskeletal modeling, respectively, whereas artificial neural networks (ANNs) were used to estimate kinetic data from low-fidelity data (e.g., subject mass, height, age, gender, static knee abduction-adduction angle, and walking speed). These data were then used as loading inputs in the knee joint FE models that were generated from magnetic resonance images. The results indicated that the high- and low-fidelity approaches provided comparable estimates of maximum principal stress, maximum shear strain, and collagen fibril strain of tibial cartilage at the first peak of knee contact force ( p > 0.05). Significant differences between the methods in the peak values of the analyzed parameters were observed at the second peak of knee contact force ( p < 0.05), larger differences observed in the lateral joint compartment. However, most of these differences disappeared when comparing average values over the cartilage–cartilage contact areas. Our findings support the potential of the low-fidelity, AI-generated approach to assess tibial cartilage mechanics. This out-of-laboratory tool may enable cartilage failure prediction and improved management of osteoarthritis.