Antonio Spinarelli

Prof. Dr. Antonio Spinarelli

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2021 in MUSCULOSKELETAL SURGERY
Verified
Journal Article
Open access
PDF file
BMBiagio Moretti
Biagio Moretti
ASAntonio Spinarelli
Antonio Spinarelli
Giustino VarrassiGiustino Varrassi
Giustino Varrassi
Leo MASSARILeo MASSARI
Leo MASSARI
AGAntonio Pompilio Gigante
Antonio Pompilio Gigante
AMAnna Maria Moretti
Anna Maria Moretti
Purpose: The exact nature of sex and gender differences in knee osteoarthritis (OA) among patient candidates for total knee arthroplasty (TKA) remains unclear and requires better elucidation to guide clinical practice. The purpose of this investigation was to survey physician practices and perceptions about the influence of sex and gender on knee OA presentation, care, and outcomes after TKA. Methods: The survey questions were elaborated by a multidisciplinary scientific board composed of 1 pain specialist, 4 orthopedic specialists, 2 physiatrists, and 1 expert in gender medicine. The survey included 5 demographic questions and 20 topic questions. Eligible physician respondents were those who treat patients during all phases of care (pain specialists, orthopedic specialists, and physiatrists). All survey responses were anonymized and handled via remote dispersed geographic participation. Results: Fifty-six physicians (71% male) accepted the invitation to complete the survey. In general, healthcare professionals expressed that women presented worse symptomology, higher pain intensity, and lower pain tolerance and necessitated a different pharmacological approach compared to men. Pain and orthopedic specialists were more likely to indicate sex and gender differences in knee OA than physiatrists. Physicians expressed that the absence of sex and gender-specific instruments and indications is an important limitation on available studies. Conclusions: Healthcare professionals perceive multiple sex and gender-related differences in patients with knee OA, especially in the pre- and perioperative phases of TKA. Sex and gender bias sensitivity training for physicians can potentially improve the objectivity of care for knee OA among TKA candidates.

13 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
EGEnrique Gómez-Barrena
Enrique Gómez-Barrena
TWTimothy Warren
Timothy Warren
IWIan Walker
Ian Walker
NJNeil Jain
Neil Jain
NKNanne Kort
Nanne Kort
BTBasilio de la Torre
Basilio de la Torre
Periprosthetic joint infection (PJI) is a devastating complication in total hip and knee replacement. Its prevention is key to decrease the incidence and avoid some consequences that seriously impact patients and health systems. In view of the variety of recommendations and guidelines, we decided to conduct an expert, peer-reviewed European consensus analysis about the pre-, intra-, and postoperative prevention of PJI. A multinational group of practicing orthopedic experts developed a series of 47 consensus statements in 6 main groups of intervention, and a 2-stage Delphi approach was launched with a threshold for agreement at 75% and for very high agreement at more than 90%. A total of 306 orthopedic surgeon responses were gathered from 9 countries. Consensus was reached for 42/47 statements, 31/47 of which achieved a very high consensus. Many preoperative actions gathered strong consensus, although areas like the use of alcoholic chlorhexidine or the timing of hair removal did not attain strong consensus, despite available evidence. Intra- and postoperative actions showed more variability regarding incise drapes, skin suturing techniques, and wound follow-up. This study confirms an important consensus among orthopedic surgeons across Europe in many areas well known to contribute to the prevention of PJI; however, there are still grounds for improvement.

1 April 2019 in JBJS Case Connector
Verified
Journal Article
Closed access
ALAlfredo Lamberti
Alfredo Lamberti
FLFrancesco Loconte
Francesco Loconte
ASAntonio Spinarelli
Antonio Spinarelli
ABAndrea Baldini
Andrea Baldini
Case: A 51-year-old woman, affected by end-stage renal disease, presented with 16-month-old ruptures of the right patellar tendon and the left quadriceps tendon. Since she had been nonambulatory for more than a year, the authors decided to perform a bilateral one-staged reconstruction with an Achilles tendon allograft on the right side and a full extensor mechanism allograft on the left side, achieving excellent clinical and functional results at 57 months’ follow-up. Conclusions: Bilateral spontaneous rupture of the extensor mechanism of the knee is a rare but dramatic occurrence. Allograft can be considered as a treatment option in case of chronic lesion or delayed reconstruction, with satisfactory midterm outcomes.

8 December 2021 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
Giuseppe SolarinoGiuseppe Solarino
Giuseppe Solarino
ASAntonio Spinarelli
Antonio Spinarelli
AVAntonio Virgilio
Antonio Virgilio
FSfilippo simone
filippo simone
MBMarco Baglioni
Marco Baglioni
BMBiagio Moretti
Biagio Moretti
Despite the fact that total hip replacement is one of the most successful surgical procedures for treatment of a variety of end-stage hip diseases, the process of osteolysis and implant loosening remains a significant problem, especially in young and high-demand patients. More than 40 years ago, ceramic bearings were introduced due to their mechanical advantage in order to obtain a reduction in wear debris, and due to the conviction that it was possible to minimize friction and wear owing to their mechanical hardness, high chemical stability, surface lubrication by fluids and low friction coefficient. Together with excellent mechanical properties, ceramics have a biological inertness: eventual ceramic debris will lead to a reactive response with a high predominance of fibrocystic cells, rather than macrophagic cells, and absence of giant cells, which is ideal from a biological perspective. As a consequence, they will not trigger the granulomatous reaction necessary to induce periprosthetic osteolysis, and this clearly appears to be of great clinical relevance. In recent years, tribology in manufacturing ceramic components has progressed with significant improvements, owing to the development of the latest generation of ceramic composites that allow for an increased material density and reduced grain size. Currently, ceramic-on-ceramic bearings are considered the attractive counterparts of ceramic- or metal-on-polyethylene ones for patients with a long life expectancy. The aim of this paper is to report the results of total hip replacements performed with a ceramic-on-ceramic articulation made from a ceramic composite in a single center, focusing on its usefulness in specific preoperative diagnosis.

1 January 2016 in Muscles, Ligaments and Tendons Journal
Verified
Journal Article
Closed access
ASAntonio Spinarelli
Antonio Spinarelli
VPV. Pesce
V. Pesce
CCC. Campagna
C. Campagna
Giuseppe MaccagnanoGiuseppe Maccagnano
Giuseppe Maccagnano
BMB. Moretti
B. Moretti
According to literature, the incidence of pain in knee prostheses is on the increase. In the last decade Authors have focused attention on rotational alignment of the prosthetic components. The aim of this study is to evaluate the efficiency of a new angle, which we define as patellar angle, in order to achieve early diagnosis of malrotation. We set up a retrospective observational study recruiting 100 subjects who had undergone total knee prosthesis. 50 subjects suffered from knee anterior pain and 50 without any symptoms. Through CAT scan and VITREA software®, we were able to study the rotation of prosthetic components. We defined a new angle, which links the tibial component and the patella margins. The angles were measured by two different orthopaedic surgeons blinded to the study. The patella angle ranged from 10 to 28°, with an average value of 23.2° in the control group; in the study group the angle ranged from 26 to 34°, with an average value of 29.9°. Our data supported the reproducibility and efficacy of new angular value. It would represent a new method to detect tibial rotational malalignment. IV.

27 December 2023 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
MSMICHELA SARACCO
MICHELA SARACCO
VCVincenzo Ciriello
Vincenzo Ciriello
ASAntonio Spinarelli
Antonio Spinarelli
Giuseppe SolarinoGiuseppe Solarino
Giuseppe Solarino
RGRemo Goderecci
Remo Goderecci
GLGiandomenico Logroscino
Giandomenico Logroscino
Hip replacement has significantly improved the quality of life of patients with symptomatic hip osteoarthritis. Various bearings have been developed over the years. Each of these has advantages and disadvantages. On the one hand, Metal-on-Metal (MoM) has been associated with a high level of wear and metal ion release of chromium (Cr) and cobalt (Co). On the other hand, Ceramic-on-Ceramic (CoC) bearings, known to have a wear rate close to zero, have been associated with an increased risk of squeaking and component fracture. Ceramic-on-Metal (CoM), a hybrid hard-on-hard bearing, was proposed to overcome the CoC and MoM limits. Preliminary clinical and radiographical results have been described as favourable. Due to the failure of MoM and the increased risk of ion release and metal toxicity, CoM was withdrawn from the market without causing significant clinical complications. Data from the literature showed that CoM bearings are reliable and safe at medium- and long-term follow-up, if correctly implanted. In this narrative review, we analysed the real risks and benefits associated with the implantation of CoM bearings.