MICHELA SARACCO

Dr. MICHELA SARACCO

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2023 in EFORT Open Reviews
Verified
Journal Article
Open access
PDF file
MSMICHELA SARACCO
MICHELA SARACCO
VCVincenzo Ciriello
Vincenzo Ciriello
FDFabio D’aNgelo
Fabio D’aNgelo
LZLuigi Zagra
Luigi Zagra
GSGiuseppe Solarino
Giuseppe Solarino
GLGiandomenico Logroscino
Giandomenico Logroscino
Purpose: Intra-articular injection is a well-established and increasingly used treatment for the patient with mild-to-moderate hip osteoarthritis. The objectives of this literature review and meta-analysis are to evaluate the effect of prior intra-articular injections on the risk of periprosthetic joint infection (PJI) in patients undergoing total hip arthroplasty (THA) and to try to identify which is the minimum waiting time between hip injection and replacement in order to reduce the risk of infection. Methods: The database of PubMed, Embase, Google Scholar and Cochrane Library was systematically and independently searched, according to Preferred Reporting Items for Systematic Reviews and Meta–Analyses (PRISMA) guidelines. To assess the potential risk of bias and the applicability of the evidence found in the primary studies to the review, the Newcastle–Ottawa scale (NOS) was used. The statistical analysis was performed by using the software ’R’ version 4.2.2. Results: The pooling of data revealed an increased risk of PJI in the injection group that was statistically significative (P = 0.0427). In the attempt to identify a ’safe time interval’ between the injection and the elective surgery, we conducted a further subgroup analysis: in the subgroup 0–3 months, we noted an increased risk of PJI after injection. Conclusions: Intra-articular injection is a procedure that may increase the risk of developing periprosthetic infection. This risk is higher if the injection is performed less than 3 months before hip replacement.

23 March 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Andrea FidanzaAndrea Fidanza
Andrea Fidanza
TPTullio Perinetti
Tullio Perinetti
GLGiandomenico Logroscino
Giandomenico Logroscino
MSMICHELA SARACCO
MICHELA SARACCO
Background: Three-dimensional (3D) printing is a technology capable of creating solid objects based on the reproduction of computerised images. This technology offers revolutionary impacts on surgical practice, especially in prosthetic and traumatological surgery. Methods: 20 patients with proximal humeral fractures were divided into two groups, one of which involved the processing of a 3D model. The model made it possible to plan the positioning and dimensions of the implants. The results were then compared with those obtained according to the usual procedures. We also reported the irreparable case of a custom revision implants acetabular bone loss treated with a 3D-printed, custom-made implant. Results: In the processed 3D proximal humeral fracture series, in the face of time and costs expenses, surgical and X-ray times were shorter than in the control group. On the other hand, there were no differences in terms of blood loss. The patient who underwent acetabular re-prosthetic surgery in a 3B Paprosky bone loss was managed and solved with a 3D-printed, custom-made implant and reported excellent outcomes at a 1 year follow-up. Conclusion: Three-dimensional printing made it possible to create better pre-operative planning in traumatology in order to optimise surgical procedures and outcomes. It also made it possible to deal with large losses of bone stock in prosthetic revision surgery, even when reconstruction may have appeared impossible with traditional implants.

22 September 2021 in Orthopedic Reviews
Verified
Journal Article
Closed access
PDF file
MSMICHELA SARACCO
MICHELA SARACCO
Camillo FulchignoniCamillo Fulchignoni
Camillo Fulchignoni
Calogero VellutoCalogero Velluto
Calogero Velluto
LRLorenzo Rocchi
Lorenzo Rocchi
Introduction: Distal radius fractures are one of the most common injuries. Open reduction and internal fixation (ORIF) are the most diffused between surgical treatments. Carbon-fiber reinforced (CFR) polyetheretherketone (PEEK) plates have been proposed to prevent effects linked to stainless steel or titanium alloy traditional plates, such as radio-opacity, mismatch of bone-plate elasticity modulus, corrosion, limited fatigue life, osseointegration. Objective: This review aims to evaluate the actual safety and reliability of CFR- PEEK plates to treat distal radius fractures. Methods: Electronic databases PubMed, Google Scholars, and Cochrane Library were searched in December 2020. Eligible studies were published in peer-reviewed journals. Three authors independently selected relevant articles and discussed those. Searching identified 13 titles and abstracts, 11 manuscripts were considered eligible for the full-text analysis. Of these 11 papers, 7 studies were included in our review. Results: 215 patients were analyzed in this systematic review. The mean age of enrolled patients was 52,8 years. 34% were males and 66% were females. Fractures were classified according to AO/ASIF classification system. We reported 12 cases of complications specific to this device, such as intraoperative plate and screws rupture, erosive flexor tendons synovitis, and loosening. Conclusion: CFR-PEEK distal radius plates are potentially an alternative to traditional ones. But we believe that the use of this device does not entail a significant advantage in the treatment of distal radius fractures, as safe and low-cost traditional devices are available. Further comparative studies are needed to demonstrate the superiority of carbon devices.

30 November 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MSMICHELA SARACCO
MICHELA SARACCO
Andrea FidanzaAndrea Fidanza
Andrea Fidanza
SNStefano Necozione
Stefano Necozione
GMGiulio Maccauro
Giulio Maccauro
GLGiandomenico Logroscino
Giandomenico Logroscino
Short femoral stems, with preservation of the femoral bone stock, are commonly used in recent years for hip replacement in younger and more active patients. Obesity is increasingly spreading even in the younger population. The aim of this case-series study is to evaluate short stems compared to traditional hip prostheses in the obese population. A total of 77 consecutive patients with a BMI greater than or equal to 30 Kg/m2 were enrolled in this prospective study and were divided into two groups: 49 patients have been implanted with short stems while 28 patients were implanted with traditional stems. All the patients were treated for primary osteoarthritis or avascular necrosis and all the stems were implanted by the same surgeon using a posterior approach. Clinical (Harris Hip Score—HHS, Western Ontario and McMaster Universities Osteoarthritis Index—WOMAC, visual analogue scale—VAS, 12-item Short Form Health Survey—SF-12) and radiographic outcomes were recorded. Radiological evaluations were carried out by three different blinded surgeons. A statistical analysis was performed (chi-square, t-test, Wilcoxon Rank Sum Test, 2-factor ANOVA). At a mean follow-up of 42.6 months both groups showed a marked improvement in pain and in the clinical scores between pre- and post-surgical procedures (p < 0.05) with no significant differences between the two groups at last follow-up (p > 0.05). The radiological evaluations, with high concordance correlation between the three blinded surgeons (ICC consistently >0.80), showed good positioning and osseointegration in all cases, with no significant differences in the restoration of the joint geometry and complications. No revisions were recorded during the follow-up period. In conclusion, short stems appear to be a good option for bone preservation even in obese patients, showing comparable results to traditional implants.

17 October 2020 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Open access
PDF file
MSMICHELA SARACCO
MICHELA SARACCO
RPRocco Maria Panzera
Rocco Maria Panzera
BMBarbara Merico
Barbara Merico
FMFrancesca Madia
Francesca Madia
APAntonio Pagliei
Antonio Pagliei
LRLorenzo Rocchi
Lorenzo Rocchi
The entrapment of the ulnar nerve in Guyon’s canal (GC) is a well-known wrist canalicular syndrome which is usually followed by a gradual combination of both sensitive and motor symptomatology. However, GC nerve compression could also cause a pure hand motor dysfunction. This condition, less frequent than the classic Guyon’s syndrome, can be difficult to diagnose. Authors report a case series of eight patients affected by isolated compression of the ulnar nerve motor branch, due to piso-triquetrum or triquetro-hamate joint ganglia. Surgical technique and postoperative outcomes are discussed in this paper. The isolated compression of the ulnar nerve motor branch is a very rare clinical condition which is often linked to several causes. The rarity of the pathology is probably due to lack of knowledge and therefore to the difficulty in formulating a correct diagnosis. Surgical treatment appears to be decisive in most cases, although late diagnosis often leads to incomplete functional recovery.

1 October 2018 in Trauma & Case Reports
Verified
Journal Article
Open access
GLGiandomenico Logroscino
Giandomenico Logroscino
FDFabrizio Donati
Fabrizio Donati
MSMICHELA SARACCO
MICHELA SARACCO
LPLuciano Pilloni
Luciano Pilloni
CPCorrado Piconi
Corrado Piconi
Angular stability locking plates are commonly used in proximal humeral fractures, especially in old patients with osteoporotic bones. These implants show good results in short and midterm follow-up, but complications are not uncommon. Here we present a case report to describe a case of early failure of a proximal angular stability plate implanted in a 72 years old female with a highly unstable two part proximal humeral fracture. An optical and metallurgic analysis was also conducted to study the modalities of failure. We concluded that anatomic reduction and restoration of the medial cortical support are crucial in order to minimize the mechanical load on the bone-metal interface and to prevent mechanical failure, in particular when the fracture rim drop in the weak point of the plate that was found in the proximal two symmetric holes (Holes E).