Auwal Abubakar

Dr. Auwal Abubakar

University of Maiduguri, Maiduguri, Borno, Nigeria
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2021 in Egyptian Journal of Radiology and Nuclear Medicine
Verified
Journal Article
Open access
PDF file
MAMuhammad K. Abdulkadir
Muhammad K. Abdulkadir
APAlbert D. Piersson
Albert D. Piersson
GMGoni M. Musa
Goni M. Musa
SASadiq A. Audu
Sadiq A. Audu
Auwal AbubakarAuwal Abubakar
Auwal Abubakar
JUJosiah E. Umana
Josiah E. Umana
Background: Reports indicated that numerous factors, including inadequate personnel knowledge, contributes to insufficient patient data for setting up diagnostic reference levels (DRLs) in developing countries. This study aims to evaluate the knowledge of DRLs as an optimisation tool amongst computed tomography (CT) radiographers in northern Nigeria. This is a quantitative cross-sectional study. A structured questionnaire was devised and distributed on site to sixty-two CT radiographers in northern Nigeria. A total of fifteen questions were included in the questionnaire focusing on DRLs, dose optimisation and dose descriptors generating quantitative data concerning overall CT radiographers’ perceived knowledge and awareness about DRLs.Results: A response rate of 77.4% (48/62) was achieved. About 83.3% of the participants declare DRLs awareness, and 37.5% carried out a local dose survey. The percentage correctly perceived knowledge of concepts; DRLs was 45.8%, dose optimisation (42%) and CT dose descriptor (39%). Radiographers with work experience ranging from 4-10 years had the highest score.Conclusion: In this survey, deficiencies were noted in radiographers’ knowledge about DRLs with precise knowledge gap in the implementation of local dose survey for DRLs and optimisation. There is a need for continuous radiographers’ training with greater emphasis on dose optimisation and institutional based dose evaluation.
1

7 April 2022 in Quantum Beam Science
Verified
Journal Article
Open access
PDF file
HZH.T. Zubair
H.T. Zubair
AOAdebiyi Oresegun
Adebiyi Oresegun
Auwal AbubakarAuwal Abubakar
Auwal Abubakar
ABAzmi Basaif
Azmi Basaif
HZHafiz Zin
Hafiz Zin
DBDAVID BRADLEY
DAVID BRADLEY
The quality of treatment delivery as prescribed in radiotherapy is exceptionally important. One element that helps provide quality assurance is the ability to carry out time-resolved radiotherapy dose measurements. Reports on doped silica optical fibers scintillators using radioluminescence (RL) based radiotherapy dosimetry have indicated merits, especially regarding robustness, versatility, wide dynamic range, and high spatial resolution. Topping the list is the ability to provide time-resolved measurements, alluding to pulse-by-pulse dosimetry. For effective time-resolved dose measurements, high temporal resolution is enabled by high-speed electronics and scintillator material offering sufficiently fast rise and decay time. In the present work, we examine the influence of Ge doping on the RL response of Ge-doped silica optical fiber scintillators. We particularly look at the size of the Ge-doped core relative to the fiber diameter, and its associated effects as it is adjusted from single-mode fiber geometry to a large core-to-cladding ratio structure. The primary objective is to produce a structure that facilitates short decay times with a sufficiently large yield for time-resolved dosimetry. RL characterization was carried out using a high-energy clinical X-ray beam (6 MV), delivered by an Elekta Synergy linear accelerator located at the Advanced Medical and Dental Institute, Universiti Sains Malaysia (USM). The Ge-doped silica optical fiber scintillator samples, fabricated using chemical vapor deposition methods, comprised of large core and small core optical fiber scintillators with high and low core-to-cladding ratios, respectively. Accordingly, these samples having different Ge-dopant contents offer distinct numbers of defects in the amorphous silica network. Responses were recorded for six dose-rates (between 35 MU/min and 590 MU/min), using a photomultiplier tube setup with the photon-counting circuit capable of gating time as small as 1 μs. The samples showed linear RL response, with differing memory and afterglow effects depending on its geometry. Samples with a large core-to-cladding ratio showed a relatively short decay time (<1 ms). The results suggest a contribution of Ge-doping in affecting the triplet states of the SiO2 matrix, thereby reducing phosphorescence effects. This is a desirable feature of scintillating glass materials that enables avoiding the pulse pile-up effect, especially in high dose-rate applications. These results demonstrate the potential of Ge-doped optical-fiber scintillators, with a large core-to-cladding ratio for use in time-resolved radiation dosimetry.

9 June 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
Auwal AbubakarAuwal Abubakar
Auwal Abubakar
NZNada Alia M. Zamri
Nada Alia M. Zamri
SSShazril Imran Shaukat
Shazril Imran Shaukat
HZHafiz Zin
Hafiz Zin
Purpose Each radiotherapy center should have a site-specific planning target volume (PTV) margins and image-guided (IG) radiotherapy (IGRT) correction protocols to compensate for the geometric errors that can occur during treatment. This study developed an automated algorithm for the calculation and evaluation of these parameters from cone beam computed tomography (CBCT)-based IG-intensity modulated radiotherapy (IG-IMRT) treatment. Methods and materials A MATLAB algorithm was developed to extract the setup errors in three translational directions (x, y, and z) from the data logged by the CBCT system during treatment delivery. The algorithm also calculates the resulted population setup error and PTV margin based on the van Herk margin recipe and subsequently estimates their respective values for no action level (NAL) and extended no action level (eNAL) offline correction protocols. The algorithm was tested on 25 head and neck cancer (HNC) patients treated using IG-IMRT. Results The algorithms calculated that the HNC patients require a PTV margin of 3.1, 2.7, and 3.2 mm in the x-, y-, and z-direction, respectively, without IGRT. The margin can be reduced to 2.0, 2.2, and 3.0 mm in the x-, y-, and z-direction, respectively, with NAL and 1.6, 1.7, and 2.2 mm in the x-, y-, and z-direction, respectively, with eNAL protocol. The results obtained were verified to be the same with the margins calculated using an Excel spreadsheet. The algorithm calculates the weekly offline setup error correction values automatically and reduces the risk of input data error observed in the spreadsheet. Conclusions In conclusion, the algorithm provides an automated method for optimization and reduction of PTV margin using logged setup errors from CBCT-based IGRT.
1

15 June 2022 in Journal of Medical Imaging and Radiation Sciences
Verified
Journal Article
Closed access
IGI. Garba
I. Garba
AFA.M. Fatima
A.M. Fatima
MAM. Abba
M. Abba
MYM. Yakubu
M. Yakubu
YMY. Mansur
Y. Mansur
AUAminu U. Usman
Aminu U. Usman

1 March 2020 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
Auwal AbubakarAuwal Abubakar
Auwal Abubakar
SIS S Imran
S S Imran
NKNoor Khairiah A. Karim
Noor Khairiah A. Karim
MKM Z Kassim
M Z Kassim
KGK Gokula
K Gokula
HZHafiz Zin
Hafiz Zin
The study focusses on evaluation of a Time-of-flight (ToF) camera for monitoring breath-hold (BH) level during voluntary deep inspiration breath-hold radiotherapy (vDIBH-RT). A commercial Argos 3D P330 ToF camera (Bluetechnix, Austria) was used to provide the distance of the patient imaged based on the light reflected from the illuminated surface. A volunteer was recruited in this study to preliminary evaluate the performance of the ToF camera for optical surface imaging. The vDIBH-RT was simulated by instructing the patient to perform DIBH for 15 seconds during ToF imaging. A small region was selected on the image of the patient’s chest surface, mid-way between the nipples. 200 consecutive ToF images of the selected area were captured during the DIBH. Imaging was repeated during free breathing (FB). These were performed for two times (representing fractions) to evaluate the inter-fraction variability. MATLAB (MathWork, Natick, MA) was used to calculate the average distance and standard deviation (SD) across each set of images acquired during a DIBH representing the BH level and BH stability, respectively. The inter-fraction variability defined as the difference between fraction-1 and fraction-2 was 4.5 mm ± 0.86. The BH stability for both sessions were within 1 mm. The distance measured during free breathing shows traces similar to the respiratory pattern obtained when using spirometry system. In conclusion, the ToF camera has potential in monitoring BH during DIBH-RT for breast cancer.

11 December 2017 in Journal of Radiotherapy in Practice
Verified
Journal Article
Closed access
Auwal AbubakarAuwal Abubakar
Auwal Abubakar
ABAdamu D. Bojude
Adamu D. Bojude
AUAminu U. Usman
Aminu U. Usman
IGIdris Garba
Idris Garba
AOAbasiama D. Obotiba
Abasiama D. Obotiba
UAUmar Abubakar
Umar Abubakar
1