Background: Reports indicated that numerous factors, including inadequate personnel knowledge, contributes to insufficient patient data for setting up diagnostic reference levels (DRLs) in developing countries. This study aims to evaluate the knowledge of DRLs as an optimisation tool amongst computed tomography (CT) radiographers in northern Nigeria. This is a quantitative cross-sectional study. A structured questionnaire was devised and distributed on site to sixty-two CT radiographers in northern Nigeria. A total of fifteen questions were included in the questionnaire focusing on DRLs, dose optimisation and dose descriptors generating quantitative data concerning overall CT radiographers’ perceived knowledge and awareness about DRLs.Results: A response rate of 77.4% (48/62) was achieved. About 83.3% of the participants declare DRLs awareness, and 37.5% carried out a local dose survey. The percentage correctly perceived knowledge of concepts; DRLs was 45.8%, dose optimisation (42%) and CT dose descriptor (39%). Radiographers with work experience ranging from 4-10 years had the highest score.Conclusion: In this survey, deficiencies were noted in radiographers’ knowledge about DRLs with precise knowledge gap in the implementation of local dose survey for DRLs and optimisation. There is a need for continuous radiographers’ training with greater emphasis on dose optimisation and institutional based dose evaluation.
1
5 February 2021 in Radiation Physics and Chemistry
Clinical challenges in pediatrics dose estimation by the displayed computed tomography (CT) dose indices may lead to inaccuracy, and thus size-specific dose estimate (SSDE) is introduced for better-personalized dose estimation. This study aims to estimate pediatric dose adapted to specific size. This retrospective study involved pediatric population aged 0–12 y. SSDE was derived from scanner reported volume CT dose index (CTDIvol), based on individual effective diameter (Deff) with corresponding size correction factors. The correlations of Deff with other associated factors such as age, exposure setting, CTDIvol and SSDE were also studied. The average Deff of Malaysian pediatric was smaller than reference phantom size (confidence interval, CI = 0.28, mean = 14.79) and (CI = 0.51, mean = 16.33) for head and abdomen, respectively. These have led to underestimation of pediatric dose as SSDE was higher than displayed CTDIvol. The percentage differences were statistically significant (p < .001) ranged from 0 to 17% and 37 to 60% for head and abdominal CT, respectively. In conclusion, the clinical implementation of SSDE in pediatric CT imaging is highly relevant to reduce radiation risk.
Background and Purpose: Size-specific dose estimates (SSDE) have been introduced into computed tomography (CT) dosimetry to tailor patients’ unique sizes to facilitate accurate CT radiation dose quantification and optimization. The purpose of this study was to develop and validate an automated algorithm for the determination of patient size (effective diameter) and SSDE. Materials and Methods: A MATLAB platform was used to develop software of algorithms based on image segmentation techniques to automate the calculation of patient size and SSDE. The algorithm was used to automatically estimate the individual size and SSDE of four CT dose index phantoms and 80 CT images of pediatric patients comprising head, thorax, and abdomen scans. For validation, the American Association of Physicists in Medicine (AAPM) manual methods were used to determine the patient’s size and SSDE for the same subjects. The accuracy of the proposed algorithm in size and SSDE calculation was evaluated for agreement with the AAPM’s estimations (manual) using Bland–Altman’s agreement and Pearson’s correlation coefficient. The normalized error, system bias, and limits of agreement (LOA) between methods were derived. Results: The results demonstrated good agreement and accuracy between the automated and AAPM’s patient size estimations with an error rate of 1.9% and 0.27% on the patient and phantoms study, respectively. A 1% percentage difference was found between the automated and manual (AAPM) SSDE estimates. A strong degree of correlation was seen with a narrow LOA between methods for clinical study ( r > 0.9771) and phantom study ( r > 0.9999). Conclusion: The proposed automated algorithm provides an accurate estimation of patient size and SSDE with negligible error after validation.