A reliable model to predict the changes in the water levels in a river is crucial for better planning to mitigate any risk associated with flooding. In this study, six different Machine Learning (ML) algorithms were developed to predict the river’s water level, on a daily basis based on collected data from 1990 to 2019 which were used to train and test the proposed models. Different input combinations were explored to improve the accuracy of the model. Statistical indicators were calculated to examine the reliability of the proposed models with other models. The comparison of several data-driven regression methods indicate that the exponential Gaussian Process Regression (GPR) model offered better accuracy in predicting daily water levels with respect to different assessment criteria. The GPR model was then used to predict the water level after sorting the data based on 10 days maximum and minimum values of the water level, and the results proved the success of this model in catching the extremes of the water levels. In addition to that, based on two uncertainty indicators, it was concluded that the proposed model, the GPR, was capable of predicting the water level of the river with high precision and less uncertainty where the computed using the 95% prediction uncertainty (95PPU) and the d-factor were found to be equal to 98.276 and 0.000525, respectively. The findings of this study show the efficacy of the GPR model in capturing the changes in the water level in a river. Due to the importance of the water level of a river being an parameter for flood monitoring, this technique is likely beneficial to the design of the mitigation strategies for future flooding events.
To accurately predict tropospheric ozone concentration(O3), it is needed to investigate the variety of artificial intelligence techniques’ performance, such as machine learning, deep learning and hybrid models. This research aims to effectively predict the hourly ozone trend via fewer input variables. This ozone prediction attempt is performed on diversity data of air pollutants (NO2, NOx, CO, SO2) and meteorological parameters (wind-speed and humidity). The historical datasets are collected from 3 sites in Malaysia. The study’s methodology progressed in two paths: standalone and hybrid models where hourly-averaged datasets are applied based on 5-time horizon analysis scenario, with different inputs’ combinations. For evaluation, all models are tested throughout 5-performance indicator and illustrated on Modified Taylor diagram. Sensitivity analysis of input variables is quantified. Additionally, uncertainty analysis is conducted to assess their confidence level associated with Willmott Index. Based on R2, results indicated that XGBoost has higher accuracy compared to MLP and SVR; meanwhile, LSTM and CNN outweighs XGBoost. In terms of robustness and accuracy, the proposed hybrid model possesses superlative performance compared to all above-mentioned techniques. The proposed model achieved exceptional results as the highest R2, the highest 95% confidence degree, and narrower confidence interval width, are 93.48%, 98.16%, and 0.0014195, respectively.
Water is the most basic need for humans and a source of livelihood for humans. Lack of human awareness to maintain water quality, causing water to become polluted, by both industrial and household waste, impacts on human health and material loss. Thus, it is important to create technology that can monitor water pollution automatically and quickly. This research aims to create a system which utilizes the Internet of Things (IoT) technology that can facilitate quality of water by measuring parameters such as pH and turbidity. The methodology of the system progresses by the usage of a controller which is ATmega328P-AU, pH sensor to measure acidity, turbidity sensor to measure turbidity level, LPWAN LoRa works like a communication of data transmission as well as cloud service, namely Antares, to store data that are sent via Android. Based on the outcomes, the proposed system has achieved a reliable accuracy with percentage error of 99.73% in pH sensor and 99.41% in the turbidity sensor. Also, 2.6 s is the average required time to deliver the results to the cloud service.