Considerable interest has been directed in recent years toward the use of self-healing materials in concrete. The concept of microcapsule healing is based on a healing agent being encapsulated and embedded in the concrete. The objective of this study was to evaluate the effects of preparation parameters, namely, temperature, agitation rate, and pH on the shell thickness and size (diameter) of the microcapsules as well as to evaluate the self-healing mechanism in concrete through experimental testing performed in laboratory. Two healing agents were evaluated in this study, i.e., dicyclopentadiene (DCPD) and sodium silicate. Based on the results of the experimental program, it was determined that, as the pH was increased from 3.0 to 3.7, the shell thickness increased for sodium silicate, while the shell thickness reached a minimum at a pH value of 3.4 for DCPD. Sodium silicate shell thickness was almost twice the shell thickness for DCPD. The most uniform and coherent microcapsules were produced at ...
1 November 2001 in Journal of Composites for Construction
Extensive testing has shown that externally bonded carbon fiber reinforced polymer (CFRP) laminates are particularly suited for improving the short-term behavior of deficient reinforced concrete beams. Accelerated fatigue tests conducted to date confirm that fatigue response is also improved. This paper describes an analytical model for simulating the static response and accelerated fatigue behavior of reinforced concrete beams strengthened with CFRP laminates. Static and fatigue calculations are carried out using a fiber section model that accounts for the nonlinear time-dependent behavior of concrete, steel yielding, and rupture of CFRP laminates. Analysis results are compared with experimental data from two sets of accelerated fatigue tests on CFRP strengthened beams and show good agreement. Cyclic fatigue causes a time-dependent redistribution of stresses, which leads to a mild increase in steel and CFRP laminate stresses as fatigue life is exhausted. Based on the findings, design considerations are suggested for the repair and/or strengthening of reinforced concrete beams using CFRP laminates.
19 July 2016 in Acta Metallurgica Sinica (English Letters)
This paper reports on a survey effort of damaged bridges conducted by the writers in the aftermath of Hurricane Katrina of August 2005. As with Hurricane Ivan in 2004, low-lying coastal bridges suffered severe damage due to hydrodynamic forces caused by storm surge. Consequently, transportation networks in the affected areas were disrupted. Since coastal bridges are considered lifelines for the communities they serve, their loss resulted in hindering rescue and recovery efforts. The purpose of this paper is to present related data as observed by the writers. Data collection and documentation of perishable data after natural disasters and before recovery and reconstruction efforts is of great importance. In the case of coastal bridges, they can help in improving future designs and rehabilitating existing ones. The majority of the surveyed bridges collapsed due to unseating. Hydrodynamic forces due to wave impact and water current on the superstructure proved to exceed the capacity of common connections bet...
This paper presents the development of a resistance model for reinforced concrete bridge girders flexurally strengthened with externally bonded carbon fiber-reinforced polymer (CFRP) laminates. The resistance model is limited to pure flexural failure and does not address shear failure, laminate debonding, or delamination. The resistance model is used to calculate the probability of failure and reliability index of CFRP-strengthened cross sections. The first-order reliability method is employed to calibrate the flexural resistance factor for a broad range of design variables. The study shows that the addition of CFRP improves reliability somewhat because the strength of CFRP laminates has a lower coefficient of variation than steel or concrete. However, the brittle nature of CFRP laminates necessitates a reliability index that is greater than that generally implied in the AASHTO LRFD for 1998. This leads to a lower resistance factor than is currently accepted for reinforced concrete sections in flexure.