In recent years, lipid nanoparticles (LNPs) have gained considerable attention in numerous research fields ranging from gene therapy to cancer immunotherapy and DNA vaccination. While some RNA-encapsulating LNP formulations passed clinical trials, DNA-loaded LNPs have been only marginally explored so far. To fulfil this gap, herein we investigated the effect of several factors influencing the microfluidic formulation and transfection behavior of DNA-loaded LNPs such as PEGylation, total flow rate (TFR), concentration and particle density at the cell surface. We show that PEGylation and post-synthesis sample concentration facilitated formulation of homogeneous and small size LNPs with high transfection efficiency and minor, if any, cytotoxicity on human Embryonic Kidney293 (HEK-293), spontaneously immortalized human keratinocytes (HaCaT), immortalized keratinocytes (N/TERT) generated from the transduction of human primary keratinocytes, and epidermoid cervical cancer (CaSki) cell lines. On the other side, increasing TFR had a detrimental effect both on the physicochemical properties and transfection properties of LNPs. Lastly, the effect of particle concentration at the cell surface on the transfection efficiency (TE) and cell viability was largely dependent on the cell line, suggesting that its case-by-case optimization would be necessary. Overall, we demonstrate that fine tuning formulation and microfluidic parameters is a vital step for the generation of highly efficient DNA-loaded LNPs.
Carboxymethyl-dextran (CMD)-coated iron oxide nanoparticles (IONs) are of great interest in nanomedicine, especially for applications in drug delivery. To develop a magnetically controlled drug delivery system, many factors must be considered, including the composition, surface properties, size and agglomeration, magnetization, cytocompatibility, and drug activity. This study reveals how the CMD coating thickness can influence these particle properties. ION@CMD are synthesized by co-precipitation. A higher quantity of CMD leads to a thicker coating and a reduced superparamagnetic core size with decreasing magnetization. Above 12.5–25.0 g L−1 of CMD, the particles are colloidally stable. All the particles show hydrodynamic diameters < 100 nm and a good cell viability in contact with smooth muscle cells, fulfilling two of the most critical characteristics of drug delivery systems. New insights into the significant impact of agglomeration on the magnetophoretic behavior are shown. Remarkable drug loadings (62%) with the antimicrobial peptide lasioglossin and an excellent efficiency (82.3%) were obtained by covalent coupling with the EDC/NHS (N-ethyl-N′-(3-(dimethylamino)propyl)carbodiimide/N-hydroxysuccinimide) method in comparison with the adsorption method (24% drug loading, 28% efficiency). The systems showed high antimicrobial activity with a minimal inhibitory concentration of 1.13 µM (adsorption) and 1.70 µM (covalent). This system successfully combines an antimicrobial peptide with a magnetically controllable drug carrier.
1 February 2021 in Journal of Applied Crystallography
An automatic sample changer system for measurements of large numbers of liquid samples – the µDrop Sample Changer – is presented. It is based on a robotic arm equipped with a pipetting mechanism, which is combined with a novel drop-based sample holder. In this holder a drop of liquid is suspended between two parallel plates by surface tension. The absence of a transfer line benefits the cleaning, improving the background as well as making it faster and more efficient than most comparable capillary-based systems. The µDrop Sample Changer reaches cycle times below 35 s and can process up to 480 samples in a single run. Sample handling is very reliable, with a drop misplacement chance of about 0.2%. Very low sample volumes (<20 µl) are needed and repeatable measurements were performed down to 6 µl. Using measurements of bovine serum albumin and lysozyme, the performance of the instrument and quality of the gathered data of low and high concentrations of proteins are presented. The temperature of samples can also be controlled during storage and during measurement, which is demonstrated by observing a phase transition of a mesophase-forming lipid solution. The instrument has been developed for use in small-angle X-ray scattering experiments, which is a well established technique for measuring (macro-)molecules. It is commonly used in biological studies, where often large sets of rare samples have to be measured.
Background: Poor prognosis of pancreatic ductal adenocarcinoma (PDAC) is mainly due to the lack of effective early-stage detection strategies. Even though the link between inflammation and PDAC has been demonstrated and inflammatory biomarkers proved their efficacy in predicting several tumours, to date they have a role only in assessing PDAC prognosis. Recently, the studies of interactions between nanosystems and easily collectable biological fluids, alone or coupled with standard laboratory tests, have proven useful in facilitating PDAC diagnosis. Notably, tests based on magnetic levitation (MagLev) of biocoronated nanosystems have demonstrated high diagnostic accuracy in compliance with the criteria stated by WHO. Herein, the author developed a synergistic analysis that combines a user-friendly MagLev-based approach and common inflammatory biomarkers for discriminating PDAC subjects from healthy ones. Materials and Methods: Plasma samples from 24 PDAC subjects and 22 non-oncological patients have been collected and let to interact with graphene oxide nanosheets. Biomolecular corona formed around graphene oxide nanosheets have been immersed in a Maglev platform to study the levitation profiles. Inflammatory biomarkers such as neutrophil-to-lymphocyte ratio (NLR), derived-NLR (dNLR), and platelet to lymphocyte ratio have been calculated and combined with results obtained by the MagLev platform. Results: MagLev profiles resulted significantly different between non-oncological patients and PDAC and allowed to identify a MagLev fingerprint for PDAC. Four inflammatory markers were significantly higher in PDAC subjects: neutrophils (P=0.04), NLR (P=4.7 ×10−6), dNLR (P=2.7 ×10−5), and platelet to lymphocyte ratio (P=0.002). Lymphocytes were appreciably lower in PDACs (P=2.6 ×10−6). Combining the MagLev fingerprint with dNLR and NLR returned global discrimination accuracy for PDAC of 95.7% and 91.3%, respectively. Conclusions: The multiplexed approach discriminated PDAC patients from healthy volunteers in up to 95% of cases. If further confirmed in larger-cohort studies, this approach may be used for PDAC detection.
Pancreatic Ductal Adeno Carcinoma (PDAC) is one of the most lethal malignancies worldwide, and the development of sensitive and specific technologies for its early diagnosis is vital to reduce morbidity and mortality rates. In this proof-of-concept study, we demonstrate the diagnostic ability of magnetic levitation (MagLev) to detect PDAC by using levitation of graphene oxide (GO) nanoparticles (NPs) decorated by a biomolecular corona of human plasma proteins collected from PDAC and non-oncological patients (NOP). Levitation profiles of corona-coated GO NPs injected in a MagLev device filled with a paramagnetic solution of dysprosium(III) nitrate hydrate in water enables to distinguish PDAC patients from NOP with 80% specificity, 100% sensitivity, and global classification accuracy of 90%. Our findings indicate that Maglev could be a robust and instrumental tool for the early detection of PDAC and other cancers.
Lamellar and non-lamellar liquid crystalline nanodispersions, including liposomes, cubosomes, and hexosomes are attractive platforms for drug delivery, bio-imaging, and related pharmaceutical applications. As compared to liposomes, there is a modest number of reports on the continuous production of cubosomes and hexosomes. Using a binary lipid mixture of citrem and soy phosphatidylcholine (SPC), we describe the continuous production of nanocarriers for delivering thymoquinone (TQ, a substance with various therapeutic potentials) by employing a commercial microfluidic hydrodynamic flow-focusing chip. In this study, nanoparticle tracking analysis (NTA) and synchrotron small-angle X-ray scattering (SAXS) were employed to characterize TQ-free and TQ-loaded citrem/SPC nanodispersions. Microfluidic synthesis led to formation of TQ-free and TQ-loaded nanoparticles with mean sizes around 115 and 124 nm, and NTA findings indicated comparable nanoparticle size distributions in these nanodispersions. Despite the attractiveness of the microfluidic chip for continuous production of citrem/SPC nano-self-assemblies, it was not efficient as comparable mean nanoparticle sizes were obtained on employing a batch (discontinuous) method based on low-energy emulsification method. SAXS results indicated the formation of a biphasic feature of swollen lamellar (Lα) phase in coexistence with an inverse bicontinuous cubic Pn3m phase in all continuously produced TQ-free and TQ-loaded nanodispersions. Further, a set of SAXS experiments were conducted on samples prepared using the batch method for gaining further insight into the effects of ethanol and TQ concentration on the structural features of citrem/SPC nano-self-assemblies. We discuss these effects and comment on the need to introduce efficient microfluidic platforms for producing nanocarriers for delivering TQ and other therapeutic agents.