Betsy D. M. Chaparro-Rico

Dr. Betsy D. M. Chaparro-Rico

Istituto Neurologico Mediterraneo, Pozzilli, Italy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2021 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
Jhon Rodriguez LeonJhon Rodriguez Leon
Jhon Rodriguez Leon
Betsy D. M. Chaparro-RicoBetsy D. M. Chaparro-Rico
Betsy D. M. Chaparro-Rico
Matteo RussoMatteo Russo
Matteo Russo
Daniele CafollaDaniele Cafolla
Daniele Cafolla
Out of all the changes to our daily life brought by the COVID-19 pandemic, one of the most significant ones has been the limited access to health services that we used to take for granted. Thus, in order to prevent temporary injuries from having lingering or permanent effects, the need for home rehabilitation device is urgent. For this reason, this paper proposes a cable-driven device for limb rehabilitation, CUBE2, with a novel end-effector (EE) design and autotuning capabilities to enable autonomous use. The proposed design is presented as an evolution of the previous CUBE design. In this paper, the proposed device is modelled and analyzed with finite element analysis. Then, a novel vision-based control strategy is described. Furthermore, a prototype has been manufactured and validated experimentally. Preliminary test to estimate home position repeatability has been carried out.

20 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Betsy D. M. Chaparro-RicoBetsy D. M. Chaparro-Rico
Betsy D. M. Chaparro-Rico
Daniele CafollaDaniele Cafolla
Daniele Cafolla
Studies have demonstrated the validity of Kinect-based systems to measure spatiotemporal parameters of gait. However, few studies have addressed test-retest, inter-rater and intra-rater reliability for spatiotemporal gait parameters. This study aims to assess test-retest, inter-rater and intra-rater reliability of SANE (eaSy gAit aNalysis system) as a measuring instrument for spatiotemporal gait parameters. SANE comprises a depth sensor and a software that automatically estimates spatiotemporal gait parameters using distances between ankles without the need to manually indicate where each gait cycle begins and ends. Gait analysis was conducted by 2 evaluators for 12 healthy subjects during 4 sessions. The reliability was evaluated using Intraclass Correlation Coefficients (ICC). In addition, the Standard Error of the Measurement (SEM), and Smallest Detectable Change (SDC) was calculated. SANE showed from an acceptable to an excellent test-retest, inter-rater and intra-rater reliability; test-retest reliability ranged from 0.62 to 0.81, inter-rater reliability ranged from 0.70 to 0.95 and intra-rater ranged from 0.74 to 0.92. The subject behavior had a greater effect on the reliability of SANE than the evaluator performance. The reliability values of SANE were comparable with other similar studies. SANE, as a feasible and markerless system, has large potential for assessing spatiotemporal gait parameters.

21 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Betsy D. M. Chaparro-RicoBetsy D. M. Chaparro-Rico
Betsy D. M. Chaparro-Rico
Daniele CafollaDaniele Cafolla
Daniele Cafolla
Marco CeccarelliMarco Ceccarelli
Marco Ceccarelli
ECEduardo Castillo-Castaneda
Eduardo Castillo-Castaneda
Patients with neurological or orthopedic lesions require assistance during therapies with repetitive movements. NURSE (cassiNo-qUeretaro uppeR-limb aSsistive dEvice) is an arm movement aid device for both right- and left-upper limb. The device has a big workspace to conduct physical therapy or training on individuals including kids and elderly individuals, of any age and size. This paper describes the mechanism design of NURSE and presents a numerical procedure for testing the mechanism feasibility that includes a kinematic, dynamic, and FEM (Finite Element Method) analysis. The kinematic demonstrated that a big workspace is available in the device to reproduce therapeutic movements. The dynamic analysis shows that commercial motors for low power consumption can achieve the needed displacement, acceleration, speed, and torque. Finite Element Method showed that the mechanism can afford the upper limb weight with light-bars for a tiny design. This work has led to the construction of a NURSE prototype with a light structure of 2.6 kg fitting into a box of 35 × 45 × 30 cm. The latter facilitates portability as well as rehabilitation at home with a proper follow-up. The prototype presented a repeatability of ±1.3 cm that has been considered satisfactory for a device having components manufactured with 3D rapid prototyping technology.

13 August 2020 in Journal of Engineering Research
Verified
Journal Article
Closed access
PDF file
Betsy D. M. Chaparro-RicoBetsy D. M. Chaparro-Rico
Betsy D. M. Chaparro-Rico
DCDaniele Cafolla
Daniele Cafolla
ECEduardo Castillo-Castaneda
Eduardo Castillo-Castaneda
MCMarco Ceccarelli
Marco Ceccarelli
VNVia Dell’eLettronica Irccs Neuromed
Via Dell’eLettronica Irccs Neuromed
CQCerro Blanco 141 Instituto Politécnico Nacional–Cicata Querétaro
Cerro Blanco 141 Instituto Politécnico Nacional–Cicata Querétaro
This paper presents the design and testing of arm exercises for rehabilitation assistance. The description of the human arm is presented together with the arm motion impairments. The motion planning for four arm exercises and the experimental procedure for data collection are described. A procedure to generate reference trajectories by regression analysis is explained. The procedure is numerically validated to prove the successfully generation of a representative trajectory for a set of trajectory samples. References trajectories are generated using the proposed procedure for four arm exercises through trajectory samples acquired from 12 subjects. The obtained reference trajectories can be used for rehabilitation assisting the traditional therapies using an automatized device.

4 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Betsy D. M. Chaparro-RicoBetsy D. M. Chaparro-Rico
Betsy D. M. Chaparro-Rico
Daniele CafollaDaniele Cafolla
Daniele Cafolla
PTPaolo Tortola
Paolo Tortola
GGGiuseppe Galardi
Giuseppe Galardi
The efficacy of Lokomat on motor recovery in stroke patients is well known. However, few studies have examined Lokomat tools to assess stiffness, joint torque and range of motion (ROM) during the subacute phase of stroke. The purpose of this retrospective observational study is to assess the changes of joint torque, ROM and stiffness that were estimated with Lokomat tools, namely L-FORCE (lower limb-force), L-ROM (lower limb-range of motion)and L-STIFF (lower limb-stiff), for paretic and non-paretic lower limbs in the subacute phase of stroke, assuming that the tools were able to measure these changes. The data come from 10 subjects in the subacute phase who had their first ever-stroke and followed a treatment that included Lokomat. The measurements came from basal assessments (T0) and one-month follow-up (T1). The measures were compared between paretic and non-paretic legs, and between T0 and T1. Significant differences in stiffness, joint torque and ROM were obtained between the paretic and non-paretic limbs at both T0 and T1. A non-significant trend was obtained for reduced stiffness and increased torque and ROM between T0 and T1 of the paretic limbs. The Lokomat tools were able to measure the changes between paretic and non-paretic legs and the small changes between T0 and T1 measurements.

DSDario Sipari
Dario Sipari
Betsy D. M. Chaparro-RicoBetsy D. M. Chaparro-Rico
Betsy D. M. Chaparro-Rico
Daniele CafollaDaniele Cafolla
Daniele Cafolla
The gait cycle of humans may be influenced by a range of variables, including neurological, orthopedic, and pathological conditions. Thus, gait analysis has a broad variety of applications, including the diagnosis of neurological disorders, the study of disease development, the assessment of the efficacy of a treatment, postural correction, and the evaluation and enhancement of sport performances. While the introduction of new technologies has resulted in substantial advancements, these systems continue to struggle to achieve a right balance between cost, analytical accuracy, speed, and convenience. The target is to provide low-cost support to those with motor impairments in order to improve their quality of life. The article provides a novel automated approach for motion characterization that makes use of artificial intelligence to perform real-time analysis, complete automation, and non-invasive, markerless analysis. This automated procedure enables rapid diagnosis and prevents human mistakes. The gait metrics obtained by the two motion tracking systems were compared to show the effectiveness of the proposed methodology.