Bharat Singh Rawat

Dr. Bharat Singh Rawat

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2024 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
LGL. T. Glöggler
L. T. Glöggler
NGN. Gusakova
N. Gusakova
BRBenjamin Rienäcker
Benjamin Rienäcker
ACA. Camper
A. Camper
RCR. Caravita
R. Caravita
ACAEḡIS Collaboration
AEḡIS Collaboration
We report on laser cooling of a large fraction of positronium (Ps) in free flight by strongly saturating the 13S−23P transition with a broadband, long-pulsed 243 nm alexandrite laser. The ground state Ps cloud is produced in a magnetic and electric field-free environment. We observe two different laser-induced effects. The first effect is an increase in the number of atoms in the ground state after the time Ps has spent in the long-lived 23P states. The second effect is one-dimensional Doppler cooling of Ps, reducing the cloud’s temperature from 380(20) to 170(20) K. We demonstrate a 58(9)% increase in the fraction of Ps atoms with v1D<3.7×104  ms−1.

4 April 2025 in Science Advances
Verified
Journal Article
Open access
MBMichael Berghold
Michael Berghold
DODavide Orsucci
Davide Orsucci
FGFrancesco Guatieri
Francesco Guatieri
SASara Alfaro
Sara Alfaro
MAMarcis Auzins
Marcis Auzins
ACAEḡIS Collaboration
AEḡIS Collaboration
Primary goal of the AEḡIS experiment is to precisely measure the free fall of antihydrogen within Earth’s gravitational field. To this end, cold (≈50 K) antihydrogen will traverse a two-grid moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here, we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations within 0.62 − 0.22 + 0.40 μm, a 35-fold improvement over the previous state of the art for real-time antiproton vertexing. These methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables in situ calibration of the moiré deflectometer, substantially reducing systematic errors. This sensor emerges as a breakthrough technology toward the AEḡIS scientific goals and will constitute the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.

1 August 2024 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
MVM. Volponi
M. Volponi
JZJakub Stanisław Zieliński
Jakub Stanisław Zieliński
TRT. Rauschendorfer
T. Rauschendorfer
SHS. Huck
S. Huck
RCR. Caravita
R. Caravita
NZN. Zurlo
N. Zurlo
Modern physics experiments are frequently very complex, relying on multiple simultaneous events to happen in order to obtain the desired result. The experiment control system plays a central role in orchestrating the measurement setup: However, its development is often treated as secondary with respect to the hardware, its importance becoming evident only during the operational phase. Therefore, the AEḡIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) collaboration has created a framework for easily coding control systems, specifically targeting atomic, quantum, and antimatter experiments. This framework, called Total Automation of LabVIEW Operations for Science (TALOS), unifies all the machines of the experiment in a single entity, thus enabling complex high-level decisions to be taken, and it is constituted by separate modules, called MicroServices, that run concurrently and asynchronously. This enhances the stability and reproducibility of the system while allowing for continuous integration and testing while the control system is running. The system demonstrated high stability and reproducibility, running completely unsupervised during the night and weekends of the data-taking campaigns. The results demonstrate the suitability of TALOS to manage an entire physics experiment in full autonomy: being open-source, experiments other than the AEḡIS experiment can benefit from it.

28 August 2025 in Instruments
Verified
Journal Article
Open access
PDF file
Bharat Singh RawatBharat Singh Rawat
Bharat Singh Rawat
Narender KumarNarender Kumar
Narender Kumar
DGDebdeep Ghosal
Debdeep Ghosal
DADaliya Aflyatunova
Daliya Aflyatunova
BRBenjamin Rienäcker
Benjamin Rienäcker
CWCarsten Welsch
Carsten Welsch
Beam diagnostics are essential tools for monitoring the performance of charged particle beams and the safe operation of particle accelerators. The performance of an accelerator is determined by evaluating the properties of beam particles, such as energy, charge, spatial, and temporal density distributions, which require very specific instruments. Faraday Cups (FCs) have emerged as important beam diagnostic devices because of their ability to accurately measure the beam charge and, in some cases, the charge distribution, which can be subsequently used to reconstruct transverse beam profiles. This paper aims to provide a detailed review of FCs, their principles, and their design challenges. FCs have applications in various scientific disciplines that include the measurement of beam current/intensity in particle accelerators, in addition to those for mass spectrometry, beam profiles/total beam currents for broad ion beams, thermonuclear fusion, and antimatter experiments. This review also covers and discusses the versatility of FCs in various scientific disciplines, along with showcasing the technological advancements that include improved collector materials, novel designs, enhanced measurement techniques, and developments in electronics and data acquisition (D.A.Q). A summary of the challenges faced while working with the FCs, such as sensitivity, calibration, and potential errors, is included in this review.

1 December 2022 in AIP Advances
Verified
Journal Article
Open access
PDF file
Bharat Singh RawatBharat Singh Rawat
Bharat Singh Rawat
SSS. K Sharma
S. K Sharma
BCB. Choksi
B. Choksi
VPV. Prahlad
V. Prahlad
UBU. K. Baruah
U. K. Baruah
The radial profiles of ion current density are measured using a combination of two techniques—fixed parallel wires and a Faraday cup array—in a ring cusp ion source. These measurements are carried out for Ar+ ion beam current in the range of 20–90 mA and energy in the range of 850–1650 eV. Current density profiles near the extraction plane of the ion source are obtained by Abel inversion of the profiles of current measured using the parallel wires. In addition, the Faraday cup array provides radial profiles of ion current density at two different locations along the beam axis. A numerical model is developed and utilized for estimating the beam divergence and focal length from the profiles of ion current density measured using the two techniques. A fixed parallel wire array is established as an effective method for monitoring the ion beam profiles close to the ion source's extraction plane when the ion beam is utilized for other applications. The performance of the two measurement techniques is compared by estimating the ion beam current from the measurement of ion current density with the beam current measured from the power supply.

1 November 2021 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
Bharat Singh RawatBharat Singh Rawat
Bharat Singh Rawat
SSS. K. Sharma
S. K. Sharma
BCB. Choksi
B. Choksi
PBP. Bharathi
P. Bharathi
BSB. Sridhar
B. Sridhar
UBU. K. Baruah
U. K. Baruah
A low-energy multipole line cusp ion source with two-grid extraction system has been developed and characterized for studying the role of the charge exchange processes on ion beam extraction, transport, and neutralization. The ion source is operated for extraction of Ar⁺ ion beam of current 50-240 mA at energies 850-1650 eV. The characterization of the ion beam is carried out at various axial positions along a 200-815-mm beam path with a background pressure of 4-20 x 10⁻⁵ Torr. An 11-channel Faraday cup array is used to measure the radial profiles of ion current density and angular beam divergence at these positions. The beam divergences are found to be in the range of 6°-15° for beam perveance of 0.50-3.75 x 10⁻⁹ AV $^{-3/2}$ . The attenuation of ion beam current along the beam path is observed due to the charge exchange neutralization of the energetic ions in the presence of high background pressure. Since ion current density along the beam path can be reduced by both the charge exchange processes and beam divergence, the accounting of beam particles, i.e., energetic ions and neutrals, at larger distances is difficult by the measurements of ion current density using the Faraday cup alone. The flux of energetic particles (energetic ions and fast neutrals) is therefore obtained by a thrust measurements on a beam target fixed at a distance of 800 mm from the ion source. The neutralization of the ion beam obtained by the emission of electrons from a hot filament neutralizer is also investigated in the presence of the charge exchange processes. Space-charge neutralization is provided initially by the secondary electrons emitted from the vessel walls or by the charge exchange processes even without the neutralizer operating at the desired temperature. However, the current neutralization is achieved only by the electrons emitted from the hot filament neutralizer operating in a space-charge-limited mode.