Bino Abel Varghese

Prof. Bino Abel Varghese

University of Southern California, Los Angeles, California, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
BVBino Abel Varghese
Bino Abel Varghese
FCFrank Chen
Frank Chen
DHDarryl Hwang
Darryl Hwang
SPSuzanne L Palmer
Suzanne L Palmer
AAAndre Luis De Castro Abreu
Andre Luis De Castro Abreu
GPGaurav Pandey
Gaurav Pandey
Multiparametric magnetic resonance imaging (mpMRI) has become increasingly important for the clinical assessment of prostate cancer (PCa), but its interpretation is generally variable due to its relatively subjective nature. Radiomics and classification methods have shown potential for improving the accuracy and objectivity of mpMRI-based PCa assessment. However, these studies are limited to a small number of classification methods, evaluation using the AUC score only, and a non-rigorous assessment of all possible combinations of radiomics and classification methods. This paper presents a systematic and rigorous framework comprised of classification, cross-validation and statistical analyses that was developed to identify the best performing classifier for PCa risk stratification based on mpMRI-derived radiomic features derived from a sizeable cohort. This classifier performed well in an independent validation set, including performing better than PI-RADS v2 in some aspects, indicating the value of objectively interpreting mpMRI images using radiomics and classification methods for PCa risk assessment.

15 August 2020 in European Radiology
Verified
Journal Article
Closed access
PDF file
FYFelix Y. Yap
Felix Y. Yap
BVBino Abel Varghese
Bino Abel Varghese
SCSteven Y. Cen
Steven Y. Cen
DHDarryl H. Hwang
Darryl H. Hwang
XLXiaomeng Lei
Xiaomeng Lei
VDVinay A. Duddalwar
Vinay A. Duddalwar

20 June 2019 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
BVBino Abel Varghese
Bino Abel Varghese
DHDarryl Hwang
Darryl Hwang
SCSteven Y. Cen
Steven Y. Cen
JLJoshua Levy
Joshua Levy
DLDerek Liu
Derek Liu
VDVinay A. Duddalwar
Vinay A. Duddalwar
Objective: To determine the intra‐, inter‐ and test‐retest variability of CT‐based texture analysis (CTTA) metrics.Materials and methods: In this study, we conducted a series of CT imaging experiments using a texture phantom to evaluate the performance of a CTTA panel on routine abdominal imaging protocols. The phantom comprises of three different regions with various textures found in tumors. The phantom was scanned on two CT scanners viz. the Philips Brilliance 64 CT and Toshiba Aquilion Prime 160 CT scanners. The intra‐scanner variability of the CTTA metrics was evaluated across imaging parameters such as slice thickness, field of view, post‐reconstruction filtering, tube voltage, and tube current. For each scanner and scanning parameter combination, we evaluated the performance of eight different types of texture quantification techniques on a predetermined region of interest (ROI) within the phantom image using 235 different texture metrics. We conducted the repeatability (test‐retest) and robustness (intra‐scanner) test on both the scanners and the reproducibility test was conducted by comparing the inter‐scanner differences in the repeatability and robustness to identify reliable CTTA metrics. Reliable metrics are those metrics that are repeatable, reproducible and robust.Results: As expected, the robustness, repeatability and reproducibility of CTTA metrics are variably sensitive to various scanner and scanning parameters. Entropy of Fast Fourier Transform‐based texture metrics was overall most reliable across the two scanners and scanning conditions. Post‐processing techniques that reduce image noise while preserving the underlying edges associated with true anatomy or pathology bring about significant differences in radiomic reliability compared to when they were not used.Conclusion: Following large‐scale validation, identification of reliable CTTA metrics can aid in conducting large‐scale multicenter CTTA analysis using sample sets acquired using different imaging protocols, scanners etc.

31 August 2024 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
SASoolmaz Abbasi
Soolmaz Abbasi
HLHaoyu Lan
Haoyu Lan
JCJeiran Choupan
Jeiran Choupan
NSNasim Sheikh-Bahaei
Nasim Sheikh-Bahaei
GPGaurav Pandey
Gaurav Pandey
BVBino Abel Varghese
Bino Abel Varghese
Medical imaging datasets for research are frequently collected from multiple imaging centers using different scanners, protocols, and settings. These variations affect data consistency and compatibility across different sources. Image harmonization is a critical step to mitigate the effects of factors like inherent differences between various vendors, hardware upgrades, protocol changes, and scanner calibration drift, as well as to ensure consistent data for medical image processing techniques. Given the critical importance and widespread relevance of this issue, a vast array of image harmonization methodologies have emerged, with deep learning-based approaches driving substantial advancements in recent times. The goal of this review paper is to examine the latest deep learning techniques employed for image harmonization by analyzing cutting-edge architectural approaches in the field of medical image harmonization, evaluating both their strengths and limitations. This paper begins by providing a comprehensive fundamental overview of image harmonization strategies, covering three critical aspects: established imaging datasets, commonly used evaluation metrics, and characteristics of different scanners. Subsequently, this paper analyzes recent structural MRI (Magnetic Resonance Imaging) harmonization techniques based on network architecture, network learning algorithm, network supervision strategy, and network output. The underlying architectures include U-Net, Generative Adversarial Networks (GANs), Variational Autoencoders (VAEs), flow-based generative models, transformer-based approaches, as well as custom-designed network architectures. This paper investigates the effectiveness of Disentangled Representation Learning (DRL) as a pivotal learning algorithm in harmonization. Lastly, the review highlights the primary limitations in harmonization techniques, specifically the lack of comprehensive quantitative comparisons across different methods. The overall aim of this review is to serve as a guide for researchers and practitioners to select appropriate architectures based on their specific conditions and requirements. It also aims to foster discussions around ongoing challenges in the field and shed light on promising future research directions with the potential for significant advancements.

11 May 2020 in British Journal of Radiology
Verified
Journal Article
Closed access
AOAssad Oberai
Assad Oberai
BVBino Abel Varghese
Bino Abel Varghese
SCSteven Cen
Steven Cen
TATomas Angelini
Tomas Angelini
DHDarryl Hwang
Darryl Hwang
VDVinay Duddalwar
Vinay Duddalwar
Objective: Establish a workflow that utilizes convolutional neural nets (CNN) to classify solid, lipid-poor, contrast enhancing renal masses using multiphase contrast enhanced CT (CECT) images and to assess the performance of the resulting network. Methods: In this institutional review board approved study of 143 patients with predominantly solid, lipid-poor, contrast enhancing renal lesions (46 benign and 97 malignant), patients with a pre-operative multiphase CECT of the abdomen and pelvis obtained between June 2009 and June 2015 were retrospectively queried. Benign renal masses included oncocytoma and lipid-poor angiomyolipoma and the malignant group included clear cell, papillary, and chromophobe carcinomas. Region of interests of whole tumor volumes were manually segmented, and CT phase images with the largest cross-section of the segmented tumor in the axial plane were used for assessment. Post-surgical pathological evaluation was used to establish diagnosis. The segmented images of renal masses were used as input to a CNN. The data were augmented and split into training (83.9%) and validation sets (16.1%) to determine the hyperparameters of the CNN. Thereafter. the performance of the resulting CNN was quantified using eightfold cross-validation. Results: The CNN-based classifier demonstrated an overall accuracy of 78% (95% confidence interval: 76–80%), sensitivity of 70% (95% confidence interval: 66–74%), specificity of 81% (79–83%) and an area under the curve of 0.82. Conclusion: A CNN-based classifier to diagnose solid enhancing malignant renal masses based on multiphase CECT images was developed. Advances in knowledge: It was established that a CNN-based classifier could be trained to accurately distinguish malignant renal lesions.

20 September 2021 in Journal of Digital Imaging
Verified
Journal Article
Closed access
PDF file
MLMingxi Lei
Mingxi Lei
BVBino Abel Varghese
Bino Abel Varghese
DHDarryl Hwang
Darryl Hwang
SCSteven Cen
Steven Cen
XLXiaomeng Lei
Xiaomeng Lei
VDVinay Duddalwar
Vinay Duddalwar