Monica Blazquez-Hinarejos

Prof. Dr. Monica Blazquez-Hinarejos

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in Archives of Oral Biology
Verified
Journal Article
Closed access
Monica Blazquez-HinarejosMonica Blazquez-Hinarejos
Monica Blazquez-Hinarejos
Raúl Ayuso‐MonteroRaúl Ayuso‐Montero
Raúl Ayuso‐Montero
EJEnric Jané-Salas
Enric Jané-Salas
JLJosé López-López
José López-López

20 February 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ahmed samir mabrouk oraby elkattanAhmed samir mabrouk oraby elkattan
Ahmed samir mabrouk oraby elkattan
NVNatalia Torres Velázquez
Natalia Torres Velázquez
Monica Blazquez-HinarejosMonica Blazquez-Hinarejos
Monica Blazquez-Hinarejos
SESonia Egido-Moreno
Sonia Egido-Moreno
Raúl Ayuso‐MonteroRaúl Ayuso‐Montero
Raúl Ayuso‐Montero
José López-LópezJosé López-López
José López-López
Purpose: To conduct a comprehensive systematic review and meta-analysis on marginal bone loss (MBL) in dental implants, enhancing the understanding and management of both bone-level and tissue-level implants. Methods: MEDLINE-PubMed and Scopus databases were searched for relevant English articles (up to April 2024), assessing the MBL as the primary outcome. The relevant data were extracted, and a meta-analysis was performed to evaluate the effect of implant neck design. Results: A total of 17 studies were included for qualitative analysis. Out of the 21 articles included, 15 studies established a statistically significant difference in MBL between the study groups; however, the differences were not found to be clinically relevant. Bone-level implants with platform-switched abutments in most of the cases showed better marginal bone stability compared to tissue-level implants or bone-level implants with matching abutments. Seven RCT studies were evaluated for the MBL between bone-level and tissue-level implants. The difference in MBL between bone-level implants and tissue-level implants was statistically significant, with a greater loss of bone in bone-level implants (Mean Difference: 0.11, 95% CI:0.02 to 0.19, p = 0.01 and I2 heterogeneity: 81%, p < 0.0001). Conclusions: This review underscores the need for standardized measurement techniques, consideration of patient-specific factors in clinical decision-making, and further long-term studies to optimize dental implant success and patient outcomes.

1 January 2017 in Medicina Oral Patología Oral y Cirugia Bucal
Verified
Journal Article
Open access
Monica Blazquez-HinarejosMonica Blazquez-Hinarejos
Monica Blazquez-Hinarejos
Raúl Ayuso‐MonteroRaúl Ayuso‐Montero
Raúl Ayuso‐Montero
JAJm Alvarez-Lopez
Jm Alvarez-Lopez
MCMaria Cristina Manzanares Céspedes
Maria Cristina Manzanares Céspedes
JLJ Lopez-Lopez
J Lopez-Lopez
The goal of the current study is to assess the difference in connective tissue adherence to laser microtextured versus machined titanium abutments.Six patients were selected and each of them received 2 implants, one combined with a laser treated abutment and one with a machined abutment. After three months, the abutments were retrieved together with their surrounding gingival tissue for histological analysis. Qualitative and quantitative evaluation of microscopical images was performed to assess the presence or absence of adherence between the soft tissues and the abutment, and the percentage of soft tissue adhered to the two different surfaces.Intimate adherence between connective tissue and the laser treated abutments, while on machined abutments no adherence was detected. A significant difference was found in the percentage of surface in contact with soft tissue between both implant abutments p=0.03.Within the limitation of the current study, it can be concluded that connective tissues show enhanced adherence to microtextured abutments compared to machined abutments.

12 April 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Monica Blazquez-HinarejosMonica Blazquez-Hinarejos
Monica Blazquez-Hinarejos
CSConstanza Saka-Herrán
Constanza Saka-Herrán
VDVictor Diez-Alonso
Victor Diez-Alonso
Raúl Ayuso‐MonteroRaúl Ayuso‐Montero
Raúl Ayuso‐Montero
Eugenio Velasco-OrtegaEugenio Velasco-Ortega
Eugenio Velasco-Ortega
José López-LópezJosé López-López
José López-López
Resonance frequency analysis (RFA) is the most extended method for measuring implant stability. The implant stability quotient (ISQ) is the measure obtained by different RFA devices; however, inter- and intra-rater reliability and agreement of these instruments remain unknown. Thirty implants were placed in three different pig mandibles. ISQ was measured parallel and perpendicular (lingual) to the peg axis with Osstell® Beacon, Penguin® and MegaISQ® by two different investigators and furthermore, one performed a test-retest. Intraclass correlation coefficient was calculated to assess the intra- and inter-rater reliability. Pearson correlation coefficient was used to assess the agreement. Intraclass correlation coefficients ranged from 0.20 to 0.65 for the Osstell® Beacon; 0.57 to 0.86 for the Penguin®; and −0.01 to 0.60 for the MegaISQ®. The highest ISQ values were obtained using Penguin® (66.3) in a parallel measurement; the lowest, using the MegaISQ® (60.1) in a parallel measurement. The highest correlation values with the other devices were obtained by MegaISQ® in a parallel measurement. Osstell® Beacon and MegaISQ® showed lower reliability than Penguin®. Osstell® had good agreement for measuring ISQ both in parallel and perpendicular, and MegaISQ® had the best agreement for measuring ISQ in parallel.

21 August 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AEAya El Kanfoud Ezzarraa
Aya El Kanfoud Ezzarraa
SESonia Egido-Moreno
Sonia Egido-Moreno
Ani Matinyan HakobyanAni Matinyan Hakobyan
Ani Matinyan Hakobyan
Monica Blazquez-HinarejosMonica Blazquez-Hinarejos
Monica Blazquez-Hinarejos
BNBeatriz González Navarro
Beatriz González Navarro
José López-LópezJosé López-López
José López-López
Background/Objectives: Cardiovascular diseases (CVD) remain the leading cause of mortality worldwide. Early identification of individuals at risk is essential to reduce disease burden. Lingual varices (LV), a common oral vascular condition, have been suggested as a potential non-invasive clinical marker of systemic vascular alterations. This study aimed to evaluate the association between lingual varices and cardiovascular diseases through a systematic review and meta-analysis. Methods: A systematic review was conducted according to PRISMA guidelines and Cochrane recommendations and registered in PROSPERO (CRD420251172737). Electronic searches were performed in PubMed, Web of Science, and Scopus databases. Observational studies assessing the association between lingual varices and cardiovascular diseases in adults were included. Odds ratios (OR) with 95% confidence intervals (CI) were calculated, and meta-analysis was performed using fixed- or random-effects models depending on heterogeneity. Results: Thirteen studies involving 6322 participants were included. The overall prevalence of lingual varices was 34.8%. The meta-analysis demonstrated a significant association between lingual varices and cardiovascular disease (OR = 4.54; 95% CI: 3.35–6.17). Among the cardiovascular conditions evaluated, hypertension also showed a significant association with lingual varices (OR = 4.14; 95% CI: 1.66–10.29). Lingual varices were also significantly associated with smoking (OR = 3.06; 95% CI: 1.61–5.82) and lower extremity varicose veins (OR = 1.64; 95% CI: 1.04–2.58). No significant association was observed with sex (OR = 0.95; 95% CI: 0.67–1.34; p = 0.77). Conclusions: Lingual varices are significantly associated with cardiovascular disease. Although they may represent a readily identifiable oral finding associated with cardiovascular risk profile, the available evidence does not support their use as an independent screening or diagnostic marker. Further prospective studies are required to determine their predictive value and clinical utility.

9 November 2026 in Tomography
Verified
Journal Article
Open access
PDF file
Ahmed samir mabrouk oraby elkattanAhmed samir mabrouk oraby elkattan
Ahmed samir mabrouk oraby elkattan
MDMONICA PIÑA D'ABREU
MONICA PIÑA D'ABREU
PRPere Riutord-Sbert
Pere Riutord-Sbert
Monica Blazquez-HinarejosMonica Blazquez-Hinarejos
Monica Blazquez-Hinarejos
José López-LópezJosé López-López
José López-López
ÁGÁngel Arturo López González
Ángel Arturo López González
Background: This review examined whether within-device exposure-setting or nominal voxel-size changes in cone-beam computed tomography (CBCT) affect linear alveolar bone measurements for implant planning, separating accuracy from agreement. Methods: Database-specific search strategies and retrieval counts are reported for PubMed/MEDLINE, Ovid Embase, Scopus, and Web of Science Core Collection. Study selection is presented in the updated PRISMA flow diagram. The reported International Prospective Register of Systematic Reviews (PROSPERO) identifier is CRD420261361509. Studies were grouped by outcome, protocol contrast, and experimental model. The Quality Assessment Tool for In Vitro Studies (QUIN) appraisal was performed by one reviewer. A revision-stage source and analysis-unit audit led to withdrawal of the planned inverse-variance meta-analyses and their ±0.5 mm equivalence claims; structured study-level synthesis was used instead. Results: Eight studies addressed linear measurements; two additional reports were retained only as methodological context. Seven linear-measurement studies compared protocols within a device, and one compared different devices. All were experimental. In one five-skull study, mean absolute errors were 0.50, 0.46, and 0.51 mm at 40, 20, and 7 s, respectively. A cadaver study reported mean absolute errors of approximately 1.10–1.20 mm. Small mean between-protocol differences sometimes coexisted with impaired anatomical visibility. Repeated observations were not equivalent to independent specimens, and several required sampling variances could not be reconstructed. Conclusions: Selected within-device protocol changes may preserve average measurements under controlled experimental conditions. The evidence does not establish statistical equivalence, interchangeability of protocol classes, or clinical safety near critical anatomy. Validation in living patients is needed before broad implementation.