Ahmed samir mabrouk oraby elkattan

Dr. Ahmed samir mabrouk oraby elkattan

Dentist, Barcelonabeta, Barcelona, Catalonia, Spain
+1
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2024 in Journal of Evidence-Based Dental Practice
Verified
Journal Article
Open access
GCGisela Cristina Vianna Camolesi
Gisela Cristina Vianna Camolesi
Ahmed samir mabrouk oraby elkattanAhmed samir mabrouk oraby elkattan
Ahmed samir mabrouk oraby elkattan
JLJosé Lopez-Lopez
José Lopez-Lopez
ABAndrés Blanco-Carrión
Andrés Blanco-Carrión
AGAbel García-García
Abel García-García
MPMario Pérez-Sayáns
Mario Pérez-Sayáns
To assess the impact of photobiomodulation therapy in pain, facial oedema, and trismus mitigation in the postoperative period after lower third molar extractions. We conducted a comparison between active photobiomodulation and simulated photobiomodulation after both lower third molars extraction in the same patients, within a double-center clinical trial. The role of photobiomodulation was evaluated based on pain, measured using the VAS scale. Oedema and trismus, assessed through millimetric measurements. Additionally, analgesic consumption was monitored during the 7-day's postoperative period. The study adhered to the CONSORT checklist and was registered on the ClinicalTrials (NCT05255731). The Levene test was used to assess precision (α=0.05), and statistical analysis was performed using Jamovi software. Paired t-tests or the Wilcoxon test were employed to analyze the primary and secondary outcomes. The study included 83 patients and 166 randomization units. The study group showed a significant reduction in pain at all evaluation times (P < .01), as well as reductions in facial oedema and trismus on postoperative days 2 and 7 (P < .01). A significant difference in analgesic use was observed on all days, except on the seventh postoperative day. The photobiomodulation protocol, using an 808 nm, 100 mW Ga-Al-As diode laser, applied both intraorally and extraorally in a single 30 seconds (3 Joules/per point) postoperative session, significantly reduced pain, oedema, and trismus following mandibular third molar extraction, particularly on postoperative days 2 and 7. Photobiomodulation can be an effective complementary therapy for reducing pain, facial oedema, and trismus in patients after lower third molar extraction.

20 February 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ahmed samir mabrouk oraby elkattanAhmed samir mabrouk oraby elkattan
Ahmed samir mabrouk oraby elkattan
NVNatalia Torres Velázquez
Natalia Torres Velázquez
Monica Blazquez-HinarejosMonica Blazquez-Hinarejos
Monica Blazquez-Hinarejos
SESonia Egido-Moreno
Sonia Egido-Moreno
Raúl Ayuso‐MonteroRaúl Ayuso‐Montero
Raúl Ayuso‐Montero
José López-LópezJosé López-López
José López-López
Purpose: To conduct a comprehensive systematic review and meta-analysis on marginal bone loss (MBL) in dental implants, enhancing the understanding and management of both bone-level and tissue-level implants. Methods: MEDLINE-PubMed and Scopus databases were searched for relevant English articles (up to April 2024), assessing the MBL as the primary outcome. The relevant data were extracted, and a meta-analysis was performed to evaluate the effect of implant neck design. Results: A total of 17 studies were included for qualitative analysis. Out of the 21 articles included, 15 studies established a statistically significant difference in MBL between the study groups; however, the differences were not found to be clinically relevant. Bone-level implants with platform-switched abutments in most of the cases showed better marginal bone stability compared to tissue-level implants or bone-level implants with matching abutments. Seven RCT studies were evaluated for the MBL between bone-level and tissue-level implants. The difference in MBL between bone-level implants and tissue-level implants was statistically significant, with a greater loss of bone in bone-level implants (Mean Difference: 0.11, 95% CI:0.02 to 0.19, p = 0.01 and I2 heterogeneity: 81%, p < 0.0001). Conclusions: This review underscores the need for standardized measurement techniques, consideration of patient-specific factors in clinical decision-making, and further long-term studies to optimize dental implant success and patient outcomes.

4 August 2026 in European Journal of Dentistry
Verified
Journal Article
Open access
Ahmed samir mabrouk oraby elkattanAhmed samir mabrouk oraby elkattan
Ahmed samir mabrouk oraby elkattan
Monica Blazquez-HinarejosMonica Blazquez-Hinarejos
Monica Blazquez-Hinarejos
HAHassan Ahmed Assiri
Hassan Ahmed Assiri
SESonia Egido-Moreno
Sonia Egido-Moreno
FPFrancisco Javier Parra-Moreno
Francisco Javier Parra-Moreno
José López-LópezJosé López-López
José López-López
This randomized clinical trial aimed to assess the relation of insertion torque value (ITV) and implant stability quotient (ISQ) between bone-level (BL) and tissue-level (TL) dental implants (ISQ recorded immediately and 3 months after implant placement). A total of 90 dental implants (44 BL, 46 TL; BioHorizons Camlog, Iberica) were placed in 21 patients. ITV was recorded at placement. ISQ (Penguin device, Klockner) was measured horizontally (ISQ-H) and vertically (ISQ-V) at baseline and at the 90-day follow-up. The Mann–Whitney U test and Spearman's correlation tests (α = 0.05) were used for the analyses. No significant difference in ITV was found between the BL (36.0 ± 11.5 Ncm) and TL (38.0 ± 11.5 Ncm) groups (p = 0.381). Similarly, no significant differences were observed in baseline ISQ-H (p = 0.928) or ISQ-V (p = 0.874). At 90 days, ISQ-H values were marginally higher in the TL group (66.5 ± 20.9) compared to the BL group (57.1 ± 18.9; p = 0.029). A significant positive correlation was found between ITV and baseline ISQ (r = 0.493, p < 0.001), but not with 90-day ISQ values. Implant design (BL vs. TL) did not significantly influence ITV or ISQ. The finding of greater horizontal stability for TL implants at 90 days, while marginal, suggests a potential long-term biomechanical difference warranting further study. The dissociation between insertion torque and 90-day stability indicates that secondary stability is governed by factors beyond initial mechanical engagement.

9 November 2026 in Tomography
Verified
Journal Article
Open access
PDF file
Ahmed samir mabrouk oraby elkattanAhmed samir mabrouk oraby elkattan
Ahmed samir mabrouk oraby elkattan
MDMONICA PIÑA D'ABREU
MONICA PIÑA D'ABREU
PRPere Riutord-Sbert
Pere Riutord-Sbert
Monica Blazquez-HinarejosMonica Blazquez-Hinarejos
Monica Blazquez-Hinarejos
José López-LópezJosé López-López
José López-López
ÁGÁngel Arturo López González
Ángel Arturo López González
Background: This review examined whether within-device exposure-setting or nominal voxel-size changes in cone-beam computed tomography (CBCT) affect linear alveolar bone measurements for implant planning, separating accuracy from agreement. Methods: Database-specific search strategies and retrieval counts are reported for PubMed/MEDLINE, Ovid Embase, Scopus, and Web of Science Core Collection. Study selection is presented in the updated PRISMA flow diagram. The reported International Prospective Register of Systematic Reviews (PROSPERO) identifier is CRD420261361509. Studies were grouped by outcome, protocol contrast, and experimental model. The Quality Assessment Tool for In Vitro Studies (QUIN) appraisal was performed by one reviewer. A revision-stage source and analysis-unit audit led to withdrawal of the planned inverse-variance meta-analyses and their ±0.5 mm equivalence claims; structured study-level synthesis was used instead. Results: Eight studies addressed linear measurements; two additional reports were retained only as methodological context. Seven linear-measurement studies compared protocols within a device, and one compared different devices. All were experimental. In one five-skull study, mean absolute errors were 0.50, 0.46, and 0.51 mm at 40, 20, and 7 s, respectively. A cadaver study reported mean absolute errors of approximately 1.10–1.20 mm. Small mean between-protocol differences sometimes coexisted with impaired anatomical visibility. Repeated observations were not equivalent to independent specimens, and several required sampling variances could not be reconstructed. Conclusions: Selected within-device protocol changes may preserve average measurements under controlled experimental conditions. The evidence does not establish statistical equivalence, interchangeability of protocol classes, or clinical safety near critical anatomy. Validation in living patients is needed before broad implementation.