Bogdan Milicevic

Dr. Bogdan Milicevic

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2018 in Materials
Verified
Journal Article
Open access
PDF file
MMMiljan Milosevic
Miljan Milosevic
Dusica StojanovicDusica Stojanovic
Dusica Stojanovic
Vladimir SimicVladimir Simic
Vladimir Simic
Bogdan MilicevicBogdan Milicevic
Bogdan Milicevic
ARAndjela Radisavljevic
Andjela Radisavljevic
Milos KojicMilos Kojic
Milos Kojic
Due to the relative ease of producing nanofibers with a core–shell structure, emulsion electrospinning has been investigated intensively in making nanofibrous drug delivery systems for controlled and sustained release. Predictions of drug release rates from the poly (d,l-lactic-co-glycolic acid) (PLGA) produced via emulsion electrospinning can be a very difficult task due to the complexity of the system. A computational finite element methodology was used to calculate the diffusion mass transport of Rhodamine B (fluorescent drug model). Degradation effects and hydrophobicity (partitioning phenomenon) at the fiber/surrounding interface were included in the models. The results are validated by experiments where electrospun PLGA nanofiber mats with different contents were used. A new approach to three-dimensional (3D) modeling of nanofibers is presented in this work. The authors have introduced two original models for diffusive drug release from nanofibers to the 3D surrounding medium discretized by continuum 3D finite elements: (1) A model with simple radial one-dimensional (1D) finite elements, and (2) a model consisting of composite smeared finite elements (CSFEs). Numerical solutions, compared to experiments, demonstrate that both computational models provide accurate predictions of the diffusion process and can therefore serve as efficient tools for describing transport inside a polymer fiber network and drug release to the surrounding porous medium.

22 April 2018 in Computer Methods in Applied Mechanics and Engineering
Verified
Journal Article
Closed access
MMMiljan Milosevic
Miljan Milosevic
VSV. Simic
V. Simic
Bogdan MilicevicBogdan Milicevic
Bogdan Milicevic
EKE.J. Koay
E.J. Koay
MFM. Ferrari
M. Ferrari
Milos KojicMilos Kojic
Milos Kojic

1 November 2021 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
MSMilorad Stojadinovic
Milorad Stojadinovic
Bogdan MilicevicBogdan Milicevic
Bogdan Milicevic
SJSlobodan Janković
Slobodan Janković

28 February 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
STSmiljana Tomašević
Smiljana Tomašević
MMMiljan Milosevic
Miljan Milosevic
Bogdan MilicevicBogdan Milicevic
Bogdan Milicevic
Vladimir SimicVladimir Simic
Vladimir Simic
MPMomcilo Prodanovic
Momcilo Prodanovic
Nenad FilipovicNenad Filipovic
Nenad Filipovic
Cardiomyopathy is associated with structural and functional abnormalities of the ventricular myocardium and can be classified in two major groups: hypertrophic (HCM) and dilated (DCM) cardiomyopathy. Computational modeling and drug design approaches can speed up the drug discovery and significantly reduce expenses aiming to improve the treatment of cardiomyopathy. In the SILICOFCM project, a multiscale platform is developed using coupled macro- and microsimulation through finite element (FE) modeling of fluid–structure interactions (FSI) and molecular drug interactions with the cardiac cells. FSI was used for modeling the left ventricle (LV) with a nonlinear material model of the heart wall. Simulations of the drugs’ influence on the electro-mechanics LV coupling were separated in two scenarios, defined by the principal action of specific drugs. We examined the effects of Disopyramide and Dygoxin which modulate Ca2+ transients (first scenario), and Mavacamten and 2-deoxy adenosine triphosphate (dATP) which affect changes of kinetic parameters (second scenario). Changes of pressures, displacements, and velocity distributions, as well as pressure–volume (P-V) loops in the LV models of HCM and DCM patients were presented. Additionally, the results obtained from the SILICOFCM Risk Stratification Tool and PAK software for high-risk HCM patients closely followed the clinical observations. This approach can give much more information on risk prediction of cardiac disease to specific patients and better insight into estimated effects of drug therapy, leading to improved patient monitoring and treatment.

27 August 2022 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
Bogdan MilicevicBogdan Milicevic
Bogdan Milicevic
MIMiloš Ivanović
Miloš Ivanović
BSBoban Stojanović
Boban Stojanović
MMMiljan Milosevic
Miljan Milosevic
MKMiloš Kojić
Miloš Kojić
Nenad FilipovicNenad Filipovic
Nenad Filipovic

30 July 2024 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
AMAntonio Martino
Antonio Martino
Rossana TerraccianoRossana Terracciano
Rossana Terracciano
Bogdan MilicevicBogdan Milicevic
Bogdan Milicevic
MMMiljan Milosevic
Miljan Milosevic
Vladimir SimicVladimir Simic
Vladimir Simic
Carly FilgueiraCarly Filgueira
Carly Filgueira
Blood vessels are essential for maintaining tumor growth, progression, and metastasis, yet the tumor vasculature is under a constant state of remodeling. Since the tumor vasculature is an attractive therapeutic target, there is a need to predict the dynamic changes in intratumoral fluid pressure and velocity that occur across the tumor microenvironment (TME). The goal of this study was to obtain insight into perfusion anisotropy within lung tumors. To achieve this goal, we used the perfusion marker Hoechst 33342 and vascular endothelial marker CD31 to stain tumor sections from C57BL/6 mice harboring Lewis lung carcinoma tumors on their flank. Vasculature, capillary diameter, and permeability distribution were extracted at different time points along the tumor growth curve. A computational model was generated by applying a unique modeling approach based on the smeared physical fields (Kojic Transport Model, KTM). KTM predicts spatial and temporal changes in intratumoral pressure and fluid velocity within the growing tumor. Anisotropic perfusion occurs within two domains: capillary and extracellular space. Anisotropy in tumor structure causes the nonuniform distribution of pressure and fluid velocity. These results provide insights regarding local vascular distribution for optimal drug dosing and delivery to better predict distribution and duration of retention within the TME.