Bogdan Dugonik

Dr. Bogdan Dugonik


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2020 in Materials
Verified
Journal Article
Open access
PDF file
RŠRiko Šafarič
Riko Šafarič
Lidija Fras ZemljičLidija Fras Zemljič
Lidija Fras Zemljič
MNMiroslav Novak
Miroslav Novak
Bogdan DugonikBogdan Dugonik
Bogdan Dugonik
BBBožidar Bratina
Božidar Bratina
Simona StrnadSimona Strnad
Simona Strnad
The growth of poultry meat production is increasing industrial waste quantities every year. Feathers represent a huge part of the waste, and international directives and restrictions prevent landfilling of such biodegradable materials with high burning values. Furthermore, with their unique properties, poultry waste feathers are already a reliable resource for many byproducts, such as keratin extraction, fibres, hydrogel production, etc., all trying to achieve a high-added value. However, mass reduction of waste feathers into useful applications, such as development of alternative building materials, is also an important aspect. To take advantage of feathers’ thermal insulation capabilities, sound damping, and biodegradability, we worked towards mixing waste feathers with wood residues (wood shavings, dust, and mixed residues) for production of composite fibreboards, comparable to the market’s medium density fibreboards. The emphasis was to evaluate waste poultry feathers as the component of natural insulation composites, along with mixed waste wood residues, to improve their mechanical properties. Various composite fibreboards with different shares of wood and feathers were produced and tested for mechanical, thermal, and acoustic properties, and biodegradability, with comparison to typical particle boards on the market. The addition of waste feather fibres into the fibreboards’ structure improved thermal insulation properties, and the biodegradability of fibreboards, but decreased their bending strength. The sound transition acoustic loss results of the presented combination fibreboards with added feathers improved at mid and high frequencies. Finally, production costs are estimated based on small scale laboratory experiments of feather processing (cleaning and drying), with the assumption of cost reduction in cases of large industrial application.

21 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Bogdan DugonikBogdan Dugonik
Bogdan Dugonik
ADAleksandra Dugonik
Aleksandra Dugonik
MMMaruska Marovt
Maruska Marovt
MGMarjan Golob
Marjan Golob
The fast-growing incidence of skin cancer, especially melanoma, is the guiding principle for intense development of various digital image-capturing devices providing easier recognition of melanoma by dermatologists. Handheld and digital dermoscopy, following of mole changes with smartphones and digital analysing of mole images, is based on evaluation of the colours, shape and deep structures in the skin moles. Incorrect colour information of an image, under- or overexposed images, lack of sharpness and low resolution of the images, can lead to melanoma misdiagnosis. The purpose of our study was to determine the colour error in the image according to the given lighting conditions and different camera settings. We focused on measuring the image quality parameters of smartphones and high-resolution cameras to compare them with the results of state-of-the-art dermoscopy device systems. We applied standardised measuring methods. The spatial frequency response method was applied for measuring the sharpness and resolution of the tested camera systems. Colour images with known reference values were captured from the test target, to evaluate colour error as a CIELAB (Commission Internationale de l’Eclairage) ΔE*ab colour difference as seen by a human observer. The results of our measurements yielded two significant findings. First, all tested cameras produced inaccurate colours when operating in automatic mode, and second, the amount of sharpening was too intensive. These deficiencies can be eliminated through adjusting the camera parameters manually or by image post-production. The presented two-step camera calibration procedure improves the colour accuracy of captured clinical and dermoscopy images significantly.

31 March 2025 in Journal of Imaging
Verified
Journal Article
Open access
Bogdan DugonikBogdan Dugonik
Bogdan Dugonik
MGMarjan Golob
Marjan Golob
Marko MarhlMarko Marhl
Marko Marhl
ADAleksandra Dugonik
Aleksandra Dugonik
The rising incidence of skin cancer, particularly melanoma, underscores the need for improved diagnostic tools in dermatology. Accurate imaging plays a crucial role in early detection, yet challenges related to color accuracy, image distortion, and resolution persist, leading to diagnostic errors. This study addresses these issues by evaluating color reproduction accuracy across various imaging devices and lighting conditions. Using a ColorChecker test chart, color deviations were measured through Euclidean distances (ΔE*, ΔC*), and nonlinear color differences (ΔE00, ΔC00), while the color rendering index (CRI) and television lighting consistency index (TLCI) were used to evaluate the influence of light sources on image accuracy. Significant color discrepancies were identified among mobile phones, DSLRs, and mirrorless cameras, with inadequate dermatoscope lighting systems contributing to further inaccuracies. We demonstrate practical applications, including manual camera adjustments, grayscale reference cards, post-processing techniques, and optimized lighting conditions, to improve color accuracy. This study provides applicable solutions for enhancing color accuracy in dermatological imaging, emphasizing the need for standardized calibration techniques and imaging protocols to improve diagnostic reliability, support AI-assisted skin cancer detection, and contribute to high-quality image databases for clinical and automated analysis.

16 March 2011
Verified
Book Chapter
Open access
PDF file
Dejan DinevskiDejan Dinevski
Dejan Dinevski
RKRobi Kelc
Robi Kelc
Bogdan DugonikBogdan Dugonik
Bogdan Dugonik
Video Communication in Telemedicine | InTechOpen, Published on: 2011-03-16. Authors: Dejan Dinevski, Robi Kelc and Bogdan Dugonik

11 November 2017 in Journal of Medical Systems
Verified
Journal Article
Closed access
PDF file
Bogdan DugonikBogdan Dugonik
Bogdan Dugonik
ADA. Dugonik
A. Dugonik
DHD. Horvat
D. Horvat
BŽB. Žalik
B. Žalik
DŠD. Špelič
D. Špelič

24 February 2025 in Elektronika ir Elektrotechnika
Verified
Journal Article
Open access
PDF file
Bogdan DugonikBogdan Dugonik
Bogdan Dugonik
MGMarjan Golob
Marjan Golob
High-resolution, small-form-factor image sensors enable the integration of mobile device cameras, which are increasingly being used for photographic documentation in many fields, including medicine. With the interface and handheld dermatoscopy, the smartphone camera forms an alternative tool to professional dermatoscopic systems for performing teledermatology and teledermoscopy. For the accurate diagnosis of skin diseases, image quality is essential, with sharpness and resolution being essential criteria. This paper focusses on measuring the sharpness and resolution of cameras used for image acquisition in dermatology using the spatial frequency response (SFR) method, which is based on standardised test charts featuring characteristic slanted contrast edges, known as edge SFR (eSFR) charts. The images were captured with mirrorless and DSLR cameras, smartphones, and a professional dermatoscopy video camera under typical dermatological conditions with digital cameras, mobile phones, and professional video dermatoscopes. Captured images were analysed, and the modulation transfer function (MTF) was defined to evaluate the performance of different camera optical systems applied for dermatological imaging. The results provide insight into the strengths and limitations of the various imaging devices and highlight their effectiveness in meeting the requirements of dermatological practice.