Bogdan Dybała

Dr. Bogdan Dybała

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2011 in Materials Characterization
Verified
Journal Article
Closed access
ECEdward Chlebus
Edward Chlebus
BKBogumiła Kuźnicka
Bogumiła Kuźnicka
TKTomasz Kurzynowski
Tomasz Kurzynowski
BDBogdan Dybała
Bogdan Dybała

1 August 2014 in Archives of Civil and Mechanical Engineering
Verified
Journal Article
Closed access
EŁE. Łyczkowska
E. Łyczkowska
Patrycja Szymczyk-ZiółkowskaPatrycja Szymczyk-Ziółkowska
Patrycja Szymczyk-Ziółkowska
BDBogdan Dybała
Bogdan Dybała
ECE. Chlebus
E. Chlebus

1 January 2014 in Procedia Engineering
Verified
Journal Article
Open access
Bartosz GapińskiBartosz Gapiński
Bartosz Gapiński
Michal WieczorowskiMichal Wieczorowski
Michal Wieczorowski
LMLidia Marciniak-Podsadna
Lidia Marciniak-Podsadna
BDBogdan Dybała
Bogdan Dybała
Grzegorz ZiółkowskiGrzegorz Ziółkowski
Grzegorz Ziółkowski
Never-ending evolution of market expectations leads to new solutions in quality control. Nowadays, in most cases control of geometry in industry is carried out using devices that apply coordinate measuring technique. Since couple of years metrological computed tomography X-ray 3D has became on a market. It is the latest field of coordinate measuring technique what makes many aspects of its accuracy and possible applications still open. The paper presents information on the functioning and measurement using computed tomography X -ray 3D.Results of comparative tests carried out on a coordinate measuring machine (CMM), optical scanner, and metrology computed tomography X -ray 3D are presented. The results allow us to conclude that computed tomography makes it possible to obtain comparable results with CMM and the optical scanner. Conducted investigations show areas where the use of the devices is appropriate and those in which the device is not adequate. In the case of X- ray 3D CT considerable versatility is presented which allow to describe the measured part with a cloud of points. Obtained information has an equal density of the part exterior and interior. This allows to reliably assess the test characteristics. The difference in presented results do not exceed 0.05mm. One of the reasons for them is the method of measurement - for CMM tactile measurement causes information gap between the data points. In the case of the optical scanner is difficult to collect data points in holes of small diameter, what causes errors in the assessment of the position and diameter. For the CT, a significant reduction in the absorption of X-rays, which translates into an actual measurement volume and the occurrence of artefacts. The paper shows the effect of different research methods on the obtained results and their application areas. This information can help a potential user to select the appropriate measuring device

1 October 2012 in Forensic Science International
Verified
Journal Article
Closed access
KWKrzysztof Woźniak
Krzysztof Woźniak
EREwa Rzepecka-Woźniak
Ewa Rzepecka-Woźniak
AMArtur Moskała
Artur Moskała
JPJerzy Pohl
Jerzy Pohl
KLKatarzyna Latacz
Katarzyna Latacz
BDBogdan Dybała
Bogdan Dybała

30 December 2020 in Materials
Verified
Journal Article
Open access
PDF file
Viktoria HoppeViktoria Hoppe
Viktoria Hoppe
Patrycja Szymczyk-ZiółkowskaPatrycja Szymczyk-Ziółkowska
Patrycja Szymczyk-Ziółkowska
MRMałgorzata Rusińska
Małgorzata Rusińska
BDBogdan Dybała
Bogdan Dybała
DPDominik Poradowski
Dominik Poradowski
Maciej JaneczekMaciej Janeczek
Maciej Janeczek
The purpose of this work is to obtain comprehensive reference data of the Ti-13Nb-13Zr alloy base material: its microstructure, mechanical, and physicochemical properties. In order to obtain extensive information on the tested materials, a number of examination methods were used, including SEM, XRD, and XPS to determine the phases occurring in the material, while mechanical properties were verified with static tensile, compression, and bending tests. Moreover, the alloy’s corrosion resistance in Ringer’s solution and the cytotoxicity were investigated using the MTT test. Studies have shown that this alloy has the structure α’, α, and β phases, indicating that parts of the β phase transformed to α’, which was confirmed by mechanical properties and the shape of fractures. Due to the good mechanical properties (E = 84.1 GPa), high corrosion resistance, as well as the lack of cytotoxicity on MC3T3 and NHDF cells, this alloy meets the requirements for medical implant materials. Ti-13Nb-13Zr alloy can be successfully used in implants, including bone tissue engineering products and dental applications.

1 December 1999 in International Journal of Machine Tools and Manufacture
Verified
Journal Article
Closed access
ECEdward Chlebus
Edward Chlebus
BDBogdan Dybała
Bogdan Dybała