Brian Senf

Mr. Brian Senf

Washington State University
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2018 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
RRRavi Kondama Reddy
Ravi Kondama Reddy
RPRubin Pooni
Rubin Pooni
DZDessi Zaharieva
Dessi Zaharieva
BSBrian Senf
Brian Senf
JYJoseph El Youssef
Joseph El Youssef
PJPeter Jacobs
Peter Jacobs
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Wrist-worn activity monitors are often used to monitor heart rate (HR) and energy expenditure (EE) in a variety of settings, including more recently in medical applications. The use of real time physiological signals to inform medical systems including drug delivery systems and decision support systems will depend on the accuracy of the signals being measured including accuracy of HR and EE. Prior studies assessed accuracy of wearables only during steady state aerobic exercise. Objective: The objective of this study was to validate the accuracy of both HR and EE for two common wrist-worn devices during a variety of dynamic activities that represent various physical activities associated with daily living including structured exercise. Methods: We assessed the accuracy of both HR and EE for two common wrist-worn devices (Fitbit Charge 2TM, Garmin vívosmart® HR+) during dynamic activities. Over a two-day period, 20 healthy adults (age: 27.5 ± 6.0 yrs; BMI: 22.5 ± 2.3 kg/m2; 11 females) performed a maximal oxygen uptake test, free-weight resistance circuit, interval training session, and activities of daily living. Validity was assessed using a HR chest strap (Polar®) and portable indirect calorimetry (Cosmed). Accuracy of the commercial wearables versus research-grade standards was determined using Bland-Altman analysis, correlational analysis, and error bias. Results: Fitbit and Garmin were reasonably accurate at measuring HR but with an overall negative bias. There was more error observed during high intensity activities, when there was a lack of repetitive wrist motion, and when the exercise mode indicator was not used. The Garmin estimated HR with a mean relative error (%RE) of -3.3% ± 16.7 while Fitbit estimated HR with a %RE of -4.7% ± 19.6 across all activities. The highest error was observed during high intensity intervals on bike (Fitbit: -11.4% ± 35.7; Garmin: -14.3% ± 20.5) and lowest error during high intensity intervals on treadmill (Fitbit: -1.7% ± 11.5; Garmin: -0.5% ± 9.4). Fitbit and Garmin EE estimates differed significantly with Garmin having less negative bias (Fitbit: -19.3% ± 29.9, Garmin: -1.6% ± 30.6, P<.001) across all activities, with both correlating poorly with indirect calorimetry measures. Conclusions: Two common wrist-worn devices show good HR accuracy, with a small negative bias, and reasonable EE estimates during low to moderate intensity exercise and during a variety of common daily activities and exercise. Accuracy was compromised markedly when the activity indicator was not used on the watch or when activities involving less wrist motion such as cycle ergometry were done.

11 May 2018 in Diabetes Care
Verified
Journal Article
Open access
PDF file
JCJessica R. Castle
Jessica R. Castle
JYJoseph El Youssef
Joseph El Youssef
LWLeah M. Wilson
Leah M. Wilson
RRRavi Reddy
Ravi Reddy
NRNavid Resalat
Navid Resalat
PJPeter Jacobs
Peter Jacobs
OBJECTIVE Automated insulin delivery is the new standard for type 1 diabetes, but exercise-related hypoglycemia remains a challenge. Our aim was to determine whether a dual-hormone closed-loop system using wearable sensors to detect exercise and adjust dosing to reduce exercise-related hypoglycemia would outperform other forms of closed-loop and open-loop therapy. RESEARCH DESIGN AND METHODS Participants underwent four arms in randomized order: dual-hormone, single-hormone, predictive low glucose suspend, and continuation of current care over 4 outpatient days. Each arm included three moderate-intensity aerobic exercise sessions. The two primary outcomes were percentage of time in hypoglycemia (<70 mg/dL) and in a target range (70–180 mg/dL) assessed across the entire study and from the start of the in-clinic exercise until the next meal. RESULTS The analysis included 20 adults with type 1 diabetes who completed all arms. The mean time (SD) in hypoglycemia was the lowest with dual-hormone during the exercise period: 3.4% (4.5) vs. 8.3% (12.6) single-hormone (P = 0.009) vs. 7.6% (8.0) predictive low glucose suspend (P < 0.001) vs. 4.3% (6.8) current care where pre-exercise insulin adjustments were allowed (P = 0.49). Time in hypoglycemia was also the lowest with dual-hormone during the entire 4-day study: 1.3% (1.0) vs. 2.8% (1.7) single-hormone (P < 0.001) vs. 2.0% (1.5) predictive low glucose suspend (P = 0.04) vs. 3.1% (3.2) current care (P = 0.007). Time in range during the entire study was the highest with single-hormone: 74.3% (8.0) vs. 72.0% (10.8) dual-hormone (P = 0.44). CONCLUSIONS The addition of glucagon delivery to a closed-loop system with automated exercise detection reduces hypoglycemia in physically active adults with type 1 diabetes.

18 September 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
BSBrian Senf
Brian Senf
Woon-Hong YeoWoon-Hong Yeo
Woon-Hong Yeo
JKJong-Hoon Kim
Jong-Hoon Kim
A recent development in portable biosensors allows rapid, accurate, and on-site detection of biomarkers, which helps to prevent disease spread by the control of sources. Less invasive sample collection is necessary to use portable biosensors in remote environments for accurate on-site diagnostics and testing. For non- or minimally invasive sampling, easily accessible body fluids, such as saliva, sweat, blood, or urine, have been utilized. It is also imperative to find accurate biomarkers to provide better clinical intervention and treatment at the onset of disease. At the same time, these reliable biomarkers can be utilized to monitor the progress of the disease. In this review, we summarize the most recent development of portable biosensors to detect various biomarkers accurately. In addition, we discuss ongoing issues and limitations of the existing systems and methods. Lastly, we present the key requirements of portable biosensors and discuss ideas for functional enhancements.

23 August 2019 in Journal of Diabetes Science and Technology
Verified
Journal Article
Closed access
PDF file
LWLeah M. Wilson
Leah M. Wilson
NTNichole Tyler
Nichole Tyler
PJPeter Jacobs
Peter Jacobs
VGVirginia Gabo
Virginia Gabo
BSBrian Senf
Brian Senf
JCJessica R. Castle
Jessica R. Castle
Background: Decision support smartphone applications integrated with continuous glucose monitors may improve glycemic control in type 1 diabetes (T1D). We conducted a survey to understand trends and needs of potential users to inform the design of decision support technology. Methods: A 70-question survey was distributed October 2017 through May 2018 to adults aged 18-80 with T1D from a specialty clinic and T1D Exchange online health community ( myglu.org ). The survey responses were used to evaluate potential features of a diabetes decision support tool by Likert scale and open responses. Results: There were 1542 responses (mean age 46.1 years [SD 15.2], mean duration of diabetes 26.5 years [SD 15.8]). The majority (84.2%) have never used an app to manage diabetes; however, a large majority (77.8%) expressed interest in using a decision support app. The ability to predict and avoid hypoglycemia was the most important feature identified by a majority of the respondents, with 91% of respondents indicating the highest level of interest in these features. The task that respondents find most difficult was management of glucose during exercise (only 47% of participants were confident in glucose management during exercise). The respondents also highly desired features that help manage glucose during exercise (85% of respondents were interested). The responses identified integration and interoperability with peripheral devices/apps and customization of alerts as important. Responses from participants were generally consistent across stratified categories. Conclusions: These results provide valuable insight into patient needs in decision support applications for management of T1D.

24 January 2022 in Micro
Verified
Journal Article
Open access
PDF file
BSBrian Senf
Brian Senf
JKJong-Hoon Kim
Jong-Hoon Kim
Biosample analysis often requires the purification, separation, or fractionation of a biofluid prior to transport to the biosensor. Deterministic lateral displacement (DLD) is a size-based microfluidic separation technique that shows promise for biosample preparation. Recently, high-throughput DLD separation has been demonstrated with airfoil-shaped pillars at higher flow rates, but this also changes separation dynamics as the Reynolds number (Re) increases. In this work, the particle trajectories in the airfoil DLD with two different angle-of-attacks (AoAs) were studied at a range of Re with alterations of fluid viscosity to mimic biological fluids. Previous studies have found that the critical diameter (Dc) decreases as Re climes. We demonstrated that variations of the fluid viscosity do not alter the separation dynamics if the Re is kept constant. As the associated Re of the flow increases, the Dc decreases regardless of viscosity. The negative AoA with an airfoil DLD pillar design provided the stronger Dc shift to negate pressure increases.

19 March 2018 in JMIR Preprints
Verified
Preprint
Open access
RRRavi Kondama Reddy
Ravi Kondama Reddy
RPRubin Pooni
Rubin Pooni
DZDessi Zaharieva
Dessi Zaharieva
BSBrian Senf
Brian Senf
JYJoseph El Youssef
Joseph El Youssef
PJPeter Jacobs
Peter Jacobs
BACKGROUND Wrist-worn activity monitors are often used to monitor heart rate (HR) and energy expenditure (EE) in a variety of settings including more recently in medical applications. The use of real-time physiological signals to inform medical systems including drug delivery systems and decision support systems will depend on the accuracy of the signals being measured, including accuracy of HR and EE. Prior studies assessed accuracy of wearables only during steady-state aerobic exercise. OBJECTIVE The objective of this study was to validate the accuracy of both HR and EE for 2 common wrist-worn devices during a variety of dynamic activities that represent various physical activities associated with daily living including structured exercise. METHODS We assessed the accuracy of both HR and EE for two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) during dynamic activities. Over a 2-day period, 20 healthy adults (age: mean 27.5 [SD 6.0] years; body mass index: mean 22.5 [SD 2.3] kg/m2; 11 females) performed a maximal oxygen uptake test, free-weight resistance circuit, interval training session, and activities of daily living. Validity was assessed using an HR chest strap (Polar) and portable indirect calorimetry (Cosmed). Accuracy of the commercial wearables versus research-grade standards was determined using Bland-Altman analysis, correlational analysis, and error bias. RESULTS Fitbit and Garmin were reasonably accurate at measuring HR but with an overall negative bias. There was more error observed during high-intensity activities when there was a lack of repetitive wrist motion and when the exercise mode indicator was not used. The Garmin estimated HR with a mean relative error (RE, %) of −3.3% (SD 16.7), whereas Fitbit estimated HR with an RE of −4.7% (SD 19.6) across all activities. The highest error was observed during high-intensity intervals on bike (Fitbit: −11.4% [SD 35.7]; Garmin: −14.3% [SD 20.5]) and lowest error during high-intensity intervals on treadmill (Fitbit: −1.7% [SD 11.5]; Garmin: −0.5% [SD 9.4]). Fitbit and Garmin EE estimates differed significantly, with Garmin having less negative bias (Fitbit: −19.3% [SD 28.9], Garmin: −1.6% [SD 30.6], P<.001) across all activities, and with both correlating poorly with indirect calorimetry measures. CONCLUSIONS Two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) show good HR accuracy, with a small negative bias, and reasonable EE estimates during low to moderate-intensity exercise and during a variety of common daily activities and exercise. Accuracy was compromised markedly when the activity indicator was not used on the watch or when activities involving less wrist motion such as cycle ergometry were done.