Rubin Pooni

Rubin Pooni

Auto-generated profile, based on publicly available information

Rubin Pooni

School of Kinesiology and Health Science, York University

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2018 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
RRRavi Kondama Reddy
Ravi Kondama Reddy
RPRubin Pooni
Rubin Pooni
DZDessi Zaharieva
Dessi Zaharieva
BSBrian Senf
Brian Senf
JYJoseph El Youssef
Joseph El Youssef
PJPeter Jacobs
Peter Jacobs
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Wrist-worn activity monitors are often used to monitor heart rate (HR) and energy expenditure (EE) in a variety of settings, including more recently in medical applications. The use of real time physiological signals to inform medical systems including drug delivery systems and decision support systems will depend on the accuracy of the signals being measured including accuracy of HR and EE. Prior studies assessed accuracy of wearables only during steady state aerobic exercise. Objective: The objective of this study was to validate the accuracy of both HR and EE for two common wrist-worn devices during a variety of dynamic activities that represent various physical activities associated with daily living including structured exercise. Methods: We assessed the accuracy of both HR and EE for two common wrist-worn devices (Fitbit Charge 2TM, Garmin vívosmart® HR+) during dynamic activities. Over a two-day period, 20 healthy adults (age: 27.5 ± 6.0 yrs; BMI: 22.5 ± 2.3 kg/m2; 11 females) performed a maximal oxygen uptake test, free-weight resistance circuit, interval training session, and activities of daily living. Validity was assessed using a HR chest strap (Polar®) and portable indirect calorimetry (Cosmed). Accuracy of the commercial wearables versus research-grade standards was determined using Bland-Altman analysis, correlational analysis, and error bias. Results: Fitbit and Garmin were reasonably accurate at measuring HR but with an overall negative bias. There was more error observed during high intensity activities, when there was a lack of repetitive wrist motion, and when the exercise mode indicator was not used. The Garmin estimated HR with a mean relative error (%RE) of -3.3% ± 16.7 while Fitbit estimated HR with a %RE of -4.7% ± 19.6 across all activities. The highest error was observed during high intensity intervals on bike (Fitbit: -11.4% ± 35.7; Garmin: -14.3% ± 20.5) and lowest error during high intensity intervals on treadmill (Fitbit: -1.7% ± 11.5; Garmin: -0.5% ± 9.4). Fitbit and Garmin EE estimates differed significantly with Garmin having less negative bias (Fitbit: -19.3% ± 29.9, Garmin: -1.6% ± 30.6, P<.001) across all activities, with both correlating poorly with indirect calorimetry measures. Conclusions: Two common wrist-worn devices show good HR accuracy, with a small negative bias, and reasonable EE estimates during low to moderate intensity exercise and during a variety of common daily activities and exercise. Accuracy was compromised markedly when the activity indicator was not used on the watch or when activities involving less wrist motion such as cycle ergometry were done.

1 October 2022 in Applied Physiology, Nutrition, and Metabolism
Verified
Journal Article
Closed access
RPRubin Pooni
Rubin Pooni
HEHeather Edgell
Heather Edgell
HTHala Tamim
Hala Tamim
Jennifer L. KukJennifer L. Kuk
Jennifer L. Kuk
The purpose of this study was to examine whether using both objectively (accelerometer) and subjectively (questionnaire) measured moderate- to vigorous-intensity physical activity (MVPA) and sedentary time (SED) improves the prediction of prediabetes and type 2 diabetes (pre/T2D) using data from the Framingham Heart Study ( n = 4200). Logistic regression was used to examine the odds ratio of pre/T2D in groups cross-classified by subjective and objective MVPA and SED. Less than half of participants fell into concordant categories of MVPA and SED using subjective and objective measures, with 7.0%–9.4% of participants in the extreme discordant categories of high-low or low-high subjective–objective MVPA or SED. Low objective MVPA, regardless of subjective MVPA status, was associated with a higher prevalence of pre/T2D ( P < 0.05). When cross-classifying by MVPA and SED, the majority of participants fell into concordant categories of MVPA-SED, with <4% of participants in the extreme discordant categories of MVPA-SED. Low objective MVPA, regardless of objective SED, was associated with a higher prevalence of pre/T2D ( P < 0.05). These findings suggest that low objectively measured MVPA appears more closely associated with pre/T2D risk compared with subjective measures, and there does not appear to be an additive effect of SED on pre/T2D risk after accounting for MVPA.

1 June 2020 in Diabetes
Verified
Journal Article
Closed access
SMSarah M. Mcgaugh
Sarah M. Mcgaugh
DZDessi Zaharieva
Dessi Zaharieva
RPRubin Pooni
Rubin Pooni
NDNinoschka C. D’sOuza
Ninoschka C. D’sOuza
JYJane Yardley
Jane Yardley
MRMichael Riddell
Michael Riddell
Glycemic control may differ throughout the menstrual cycle, with increased incidence of hyperglycemia in the luteal phase. However, it is unclear if glycemic differences exist in the follicular vs. luteal phase during prolonged fasted exercise in T1D. The aim of this study was to determine if the early follicular vs. luteal phase impacts blood glucose levels during and post-exercise. Females with T1D (n = 7, age 28±6 years, A1c 6.9±0.6%) completed two 2-hr aerobic exercise sessions (∼45% VO2peak), during the luteal (days 18-24) and early-follicular phases (days 1-6) of menstruation. Carbohydrate (CHO) intake (0.3g/kg/hr) occurred every 30-min if glucose was between 72-180 mg/dL. No differences existed between the two phases for starting glucose, changes in glucose, CHO consumption and CHO oxidation during exercise (Table). Baseline glucagon was elevated in the luteal (28±25pg/mL) vs. follicular phase (13±12pg/mL; P180 mg/dL) was greater in the luteal (59±44%) vs. follicular phase (21±30%; P<0.05). Overall, glycemic responses during prolonged fasting exercise are similar between luteal and follicular phases in women with T1D, as are CHO intake needs. However, after exercise in the luteal phase, glycemia tends to be elevated and appears to contribute to greater time in hyperglycemia. Disclosure S.M. McGaugh: None. D. Zaharieva: Speaker’s Bureau; Self; Ascensia Diabetes Care, Insulet Corporation, Medtronic. R. Pooni: None. N.C. D’Souza: None. J.E. Yardley: Research Support; Self; Abbott, Dexcom, Inc., LifeScan Canada. Speaker’s Bureau; Self; Dexcom, Inc. M. Riddell: Advisory Panel; Self; Zucara Therapeutics Inc. Consultant; Self; Lilly Diabetes. Research Support; Self; Dexcom, Inc., Insulet Corporation. Speaker’s Bureau; Self; Medtronic, Novo Nordisk A/S.

19 March 2018 in JMIR Preprints
Verified
Preprint
Open access
RRRavi Kondama Reddy
Ravi Kondama Reddy
RPRubin Pooni
Rubin Pooni
DZDessi Zaharieva
Dessi Zaharieva
BSBrian Senf
Brian Senf
JYJoseph El Youssef
Joseph El Youssef
PJPeter Jacobs
Peter Jacobs
BACKGROUND Wrist-worn activity monitors are often used to monitor heart rate (HR) and energy expenditure (EE) in a variety of settings including more recently in medical applications. The use of real-time physiological signals to inform medical systems including drug delivery systems and decision support systems will depend on the accuracy of the signals being measured, including accuracy of HR and EE. Prior studies assessed accuracy of wearables only during steady-state aerobic exercise. OBJECTIVE The objective of this study was to validate the accuracy of both HR and EE for 2 common wrist-worn devices during a variety of dynamic activities that represent various physical activities associated with daily living including structured exercise. METHODS We assessed the accuracy of both HR and EE for two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) during dynamic activities. Over a 2-day period, 20 healthy adults (age: mean 27.5 [SD 6.0] years; body mass index: mean 22.5 [SD 2.3] kg/m2; 11 females) performed a maximal oxygen uptake test, free-weight resistance circuit, interval training session, and activities of daily living. Validity was assessed using an HR chest strap (Polar) and portable indirect calorimetry (Cosmed). Accuracy of the commercial wearables versus research-grade standards was determined using Bland-Altman analysis, correlational analysis, and error bias. RESULTS Fitbit and Garmin were reasonably accurate at measuring HR but with an overall negative bias. There was more error observed during high-intensity activities when there was a lack of repetitive wrist motion and when the exercise mode indicator was not used. The Garmin estimated HR with a mean relative error (RE, %) of −3.3% (SD 16.7), whereas Fitbit estimated HR with an RE of −4.7% (SD 19.6) across all activities. The highest error was observed during high-intensity intervals on bike (Fitbit: −11.4% [SD 35.7]; Garmin: −14.3% [SD 20.5]) and lowest error during high-intensity intervals on treadmill (Fitbit: −1.7% [SD 11.5]; Garmin: −0.5% [SD 9.4]). Fitbit and Garmin EE estimates differed significantly, with Garmin having less negative bias (Fitbit: −19.3% [SD 28.9], Garmin: −1.6% [SD 30.6], P<.001) across all activities, and with both correlating poorly with indirect calorimetry measures. CONCLUSIONS Two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) show good HR accuracy, with a small negative bias, and reasonable EE estimates during low to moderate-intensity exercise and during a variety of common daily activities and exercise. Accuracy was compromised markedly when the activity indicator was not used on the watch or when activities involving less wrist motion such as cycle ergometry were done.