Camilo Ordonez

Mr. Camilo Ordonez

University of Seville (Spain)
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
Camilo OrdonezCamilo Ordonez
Camilo Ordonez
AGAntonio Gomez-Exposito
Antonio Gomez-Exposito
JOJose Maria Maza Ortega
Jose Maria Maza Ortega
This paper reviews the basics of series compensation in transmission systems through a literature survey. The benefits that this technology brings to enhance the steady state and dynamic operation of power systems are analyzed. The review outlines the evolution of the series compensation technologies, from mechanically operated switches to line- and self-commutated power electronic devices, covering control issues, different applications, practical realizations, and case studies. Finally, the paper closes with the major challenges that this technology will face in the near future to achieve a fully decarbonized power system.

20 August 2013 in Electric Power Components and Systems
Verified
Journal Article
Closed access
Camilo OrdonezCamilo Ordonez
Camilo Ordonez
Mario RiosMario Rios
Mario Rios
Situational awareness has become an important subject for the operation of power systems because it will give information of the state of functioning of the system and important data for taking control actions in the power systems. Among the different aspects to be included in the situational awareness to be monitored in a wide-area monitoring system, the supervision of the behavior of damping of electromechanical modes has an important role. It is well known that this supervision corresponds to an estimation process of dynamic characteristics in a non-linear system. However, an important balance between the requirements of quantity of data and time for estimation must be achieved for this important task. So, this article proposes the utilization of both fixed sliding-window and size-controlled window analysis to be used in on-line wide-area monitoring system based identification of electromechanical modes using a multi-Prony estimation. The proposed methods are simulated for the reduced-order equivalent of the interconnected New England Test System and New York Power System.

1 July 2012
Verified
Conference Paper
Closed access
HCH. R. Chamorro
H. R. Chamorro
Camilo OrdonezCamilo Ordonez
Camilo Ordonez
JVJosé Fernando Jiménez Vargas
José Fernando Jiménez Vargas
Hierarchical coordinated control architectures applied to Microgrids (MG) are a requirement in order to monitor and supervise the power stages involved and to provide some autonomous and smartness behaviour to the grid. In this document, a hierarchical controller based on a Petri Nets methodology to low voltage MG with wind energy is applied. The control strategy designed configures and distributes the local controller actions which are in charge to manage the active and reactive power flow in grid connected and standalone modes, through Voltage Source Converter (VSC) in multi-terminal connections where wind generation are included. Simulation results show the coordination flexibility and adaptability of Petri Nets in different study cases. Finally conclusions and future work are given.

21 September 2019
Verified
Book Chapter
Closed access
PDF file
RCRodrigo Chamorro
Rodrigo Chamorro
Camilo OrdonezCamilo Ordonez
Camilo Ordonez
JPJimmy C.-H. Peng
Jimmy C.-H. Peng
FGFrancisco Gonzalez-Longatt
Francisco Gonzalez-Longatt
VSVijay K. Sood
Vijay K. Sood

1 June 2013
Verified
Conference Paper
Closed access
Mario RiosMario Rios
Mario Rios
Camilo OrdonezCamilo Ordonez
Camilo Ordonez
This paper proposes the identification of electromechanical modes based on signals obtained from Phasor Measurement Unit using a moving time window and a growing window during the post-disturbance state, considering both Prony's method and the Hankel's total least square method. Results show that the two methods can be used for online identification of oscillation modes; however, the moving window must not be shorter than the period of the lowest frequency determined by offline Eigenvalues analysis.

1 February 2018
Verified
Conference Paper
Open access
HCHarold R. Chamorro
Harold R. Chamorro
Camilo OrdonezCamilo Ordonez
Camilo Ordonez
JPJimmy C-H. Peng
Jimmy C-H. Peng
FGFrancisco Gonzalez-Longatt
Francisco Gonzalez-Longatt
VSVijay K. Sood
Vijay K. Sood
ASAdel M. Sharaf
Adel M. Sharaf
The large scale penetration of non-synchronous generation has been causing several impacts on the power systems dynamics. The low-frequency oscillations affect the power exchanged along the transmission lines/corridors. This paper uses the Multi-Prony Analysis mode estimation technique to monitor and suggest the dominant oscillation modes which can be useful for wide-area control purposes. Moreover, the oscillation modes are also monitored under gradual cases of non-synchronous generation integration in the system. The methodology is applied to two different test transmission systems: i) the two area system and, ii) the Nordic 32 system. The results illustrate the similarity and differences in the scenarios proposed.