Carina Barbosa Pereira

Dr. Carina Barbosa Pereira

Universitätsklinikum Aachen, Aachen, North Rhine-Westphalia, Germany
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2015 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
Carina Barbosa PereiraCarina Barbosa Pereira
Carina Barbosa Pereira
XYXinchi Yu
Xinchi Yu
MCMichael Czaplik
Michael Czaplik
RRRolf Rossaint
Rolf Rossaint
VBVladimir Blazek
Vladimir Blazek
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
An atypical or irregular respiratory frequency is considered to be one of the earliest markers of physiological distress. In addition, monitoring of this vital parameter plays a major role in diagnosis of respiratory disorders, as well as in early detection of sudden infant death syndrome. Nevertheless, the current measurement modalities require attachment of sensors to the patient’s body, leading to discomfort and stress. The current paper presents a new robust algorithm to remotely monitor breathing rate (BR) by using thermal imaging. This approach permits to detect and to track the region of interest (nose) as well as to estimate BR. In order to study the performance of the algorithm, and its robustness against motion and breathing disorders, three different thermal recordings of 11 healthy volunteers were acquired (sequence 1: normal breathing; sequence 2: normal breathing plus arbitrary head movements; and sequence 3: sequence of specific breathing patterns). Thoracic effort (piezoplethysmography) served as “gold standard” for validation of our results. An excellent agreement between estimated BR and ground truth was achieved. Whereas the mean correlation for sequence 1–3 were 0.968, 0.940 and 0.974, the mean absolute BR errors reached 0.33, 0.55 and 0.96 bpm (breaths per minute), respectively. In brief, this work demonstrates that infrared thermography is a promising, clinically relevant alternative for the currently available measuring modalities due to its performance and diverse remarkable advantages.

23 August 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Carina Barbosa PereiraCarina Barbosa Pereira
Carina Barbosa Pereira
XYXinchi Yu
Xinchi Yu
TGTom Goos
Tom Goos
IRIrwin Reiss
Irwin Reiss
TOThorsten W. Orlikowsky
Thorsten W. Orlikowsky
DTDaniel Teichmann
Daniel Teichmann
Monitoring of respiratory rate (RR) is very important for patient assessment. In fact, it is considered one of the relevant vital parameters in critical care medicine. Nowadays, standard monitoring relies on obtrusive and invasive techniques which require adhesive electrodes or sensors to be attached to the patient's body. Unfortunately, these procedures cause stress, pain and frequently damage the vulnerable skin of preterm infants. The current paper presents a "black-box" algorithm for remote monitoring of RR in thermal videos. "Black-box" in this context means that the algorithm does not rely on tracking of specific anatomic landmarks. Instead, it automatically distinguishes regions of interest in the video containing the respiratory signal from those containing only noise. To examine its performance and robustness during physiological (phase A) and pathological scenarios (phase B), a study on twelve healthy volunteers was carried out. After a successful validation on adults, a clinical study on eight newborn infants was conducted. A good agreement between estimated RR and ground truth was achieved. In the study involving adult volunteers, a mean root-mean-square error (RMSE) of 0.31 ± 0.09 breaths/min and 3.27 ± 0.72 breaths/min was obtained for phase A and phase B, respectively. In the study involving infants, the mean RMSE hovered around 4.15 ± 1.44 breaths/min. In brief, this paper demonstrates that infrared thermography might become a clinically relevant alternative for the currently available RR monitoring modalities in neonatal care.

24 October 2016 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Closed access
PDF file
Carina Barbosa PereiraCarina Barbosa Pereira
Carina Barbosa Pereira
XYXinchi Yu
Xinchi Yu
MCMichael Czaplik
Michael Czaplik
VBVladimir Blazek
Vladimir Blazek
BVBoudewijn Venema
Boudewijn Venema
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt

13 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Carina Barbosa PereiraCarina Barbosa Pereira
Carina Barbosa Pereira
MCMichael Czaplik
Michael Czaplik
VBVladimir Blazek
Vladimir Blazek
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
DTDaniel Teichmann
Daniel Teichmann
Heart rate (HR) and respiratory rate (RR) are important parameters for patient assessment. However, current measurement techniques require attachment of sensors to the patient’s body, often leading to discomfort, stress and even pain. A new algorithm is presented for monitoring both HR and RR using thermal imaging. The cyclical ejection of blood flow from the heart to the head (through carotid arteries and thoracic aorta) leads to periodic movements of the head; these vertical movements are used to assess HR. Respiratory rate is estimated by using temperature fluctuations under the nose during the respiratory cycle. To test the viability and feasibility of this approach, a pilot study was conducted with 20 healthy subjects (aged 18–36 and 1 aged 50 years). The study consisted of two phases: phase A (frontal view acquisitions) and phase B (side view acquisitions). To validate the results, photoplethysmography and thoracic effort (piezoplethysmography) were simultaneously recorded. High agreement between infrared thermography and ground truth/gold standard was achieved. For HR, the root-mean-square errors (RMSE) for phases A and B were 3.53 ± 1.53 and 3.43 ± 1.61 beats per minute, respectively. For RR, the RMSE between thermal imaging and piezoplethysmography stayed around 0.71 ± 0.30 breaths per minute (phase A). This study demonstrates that infrared thermography may be a promising, clinically relevant alternative for the assessment of HR and RR.

18 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
NHNadine Hochhausen
Nadine Hochhausen
Carina Barbosa PereiraCarina Barbosa Pereira
Carina Barbosa Pereira
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
RRRolf Rossaint
Rolf Rossaint
MCMichael Czaplik
Michael Czaplik
The post-anesthesia care unit (PACU) is the central hub for recovery after surgery, especially when the surgery is performed under general anesthesia. Aside from clinical aspects, respiratory impairment is one of the major causes of morbidity and affected recovery in the PACU and should therefore be monitored. In previous studies, infrared thermography was applied to assess the breathing rate (BR) of healthy volunteers. Here, the transferability of published methods for postoperative patients in the PACU was examined. Video recordings of 28 patients were acquired using a long-wave infrared camera, and analyzed offline. For validation purposes, BRs derived from body surface electrocardiography were measured simultaneously. In general, a close agreement between the two techniques (r = 0.607, p = 0.002 upon arrival, and r = 0.849, p < 0.001 upon discharge from the PACU) was obtained. In conclusion, the algorithm was demonstrated to be feasible and reliable under these challenging conditions.

6 November 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Carina Barbosa PereiraCarina Barbosa Pereira
Carina Barbosa Pereira
HDHenriette Dohmeier
Henriette Dohmeier
JKJanosch Kunczik
Janosch Kunczik
NHNadine Hochhausen
Nadine Hochhausen
RTRené Tolba
René Tolba
MCMichael Czaplik
Michael Czaplik
Pig experiments have played an important role in medical breakthroughs during the last century. In fact, pigs are one of the major animal species used in translational research, surgical models and procedural training due to their anatomical and physiological similarities to humans. To ensure high bioethical standards in animal trials, new directives have been implemented, among others, to refine the procedures and minimize animals’ stress and pain. This paper presents a contactless motion-based approach for monitoring cardiorespiratory signals (heart rate and respiratory rate) in anesthetized pigs using infrared thermography. Heart rate monitoring is estimated by measuring the vibrations (precordial motion) of the chest caused by the heartbeat. Respiratory rate, in turn, is computed by measuring the mechanical chest movements that accompany the respiratory cycle. To test the feasibility of this approach, thermal videos of 17 anesthetized pigs were acquired and analyzed. A high agreement between infrared thermography and a gold standard (electrocardiography and capnography-derived respiratory rate) was achieved. The mean absolute error averaged 3.43 ± 3.05 bpm and 0.27 ± 0.48 breaths/min for heart rate and respiratory rate, respectively. In sum, infrared thermography is capable of assessing cardiorespiratory signals in pigs. Future work should be conducted to evaluate infared thermography capability of capturing information for long term monitoring of research animals in a diverse set of facilities.