Caterina Amendola

Ms. Caterina Amendola

Politecnico di Milano - Dipartimento di Fisica
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Caterina AmendolaCaterina Amendola
Caterina Amendola
MLMichele Lacerenza
Michele Lacerenza
IPIleana Pirovano
Ileana Pirovano
DCDavide Contini
Davide Contini
LSLorenzo Spinelli
Lorenzo Spinelli
Rebecca ReRebecca Re
Rebecca Re
The interest for Fused Deposition Modelling (FDM) in the field of Diffuse Optics (DO) is rapidly increasing. The most widespread FDM materials are polylactic acid (PLA) and acrylonitrile butadiene styrene (ABS), thanks to their low cost and easiness-to-print. This is why, in this study, 3D printed samples of PLA and ABS materials were optically characterized in the range from the UV up to the IR wavelengths, in order to test their possible employment for probe construction in DO applications. To this purpose, measurements with Near Infrared Spectroscopy and Diffuse Correlation Spectroscopy techniques were considered. The results obtained show how the material employed for probe construction can negatively affect the quality of DO measurements.

15 June 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
PLPranav Lanka
Pranav Lanka
LYLin Yang
Lin Yang
DODavid Orive-Miguel
David Orive-Miguel
JVJoshua D. Veesa
Joshua D. Veesa
STSusanna Tagliabue
Susanna Tagliabue
APAntonio Pifferi
Antonio Pifferi
Diffuse optics (DO) encompasses a range of photonics tools based on the study of random photon migration in highly scattering media—biological tissues in particular. Due to its unique features, DO is emerging as a powerful means for clinical or homecare diagnostics.1 The basic physics of DO is related to the detection of temporal or spatial alteration in photon distribution re-emitted on the tissue surface.2 Due to the low power (typically few mW) of injected near-infrared light (600- to 1100-nm range), DO is inherently noninvasive. The photon temporal (or spatial) distribution carries information on the absorption—ultimately related to tissue chemical composition, such as water, lipid, collagen content, oxy- and deoxy-hemoglobin concentration, cytochrome c-oxidase3—and scattering properties—linked to tissue microstructure. Further, DO is one of the few noninvasive modalities capable of providing functional information, e.g., brain or muscle activation.4 It can be operated noncontact through remote light illumination and collection.5 It explores the tissue well below the skin at depths of up to 2 to 4 cm. It can provide quantitative operator-independent assessment of the tissue status, such as hemoglobin oxygenation level in the brain. Finally, it is highly scalable, sharing the same technology from large clinical tomographic systems down to wearable devices or homecare appliances.6 For all these aspects, DO is attracting more and more interest in many fields, such as monitoring vital signs like brain oxygenation in critical care or during interventions,7 tumor diagnostics as for breast cancer,8 investigating the impact of lifestyle and nutrition on our body,9 or other fields such as neuroscience and psychology,10 sports, and leisure.11 Even further, the operator independence, the depth sensitivity, and the scalability in addition to noninvasiveness make this option attractive for telemedicine and homecare of patients remotely.

28 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Caterina AmendolaCaterina Amendola
Caterina Amendola
MLMichele Lacerenza
Michele Lacerenza
MBMauro Buttafava
Mauro Buttafava
ATAlberto Tosi
Alberto Tosi
LSLorenzo Spinelli
Lorenzo Spinelli
Alessandro TorricelliAlessandro Torricelli
Alessandro Torricelli
In this work, we present a new multi-distance diffuse correlation spectroscopy (DCS) device integrated with a compact state-of-the-art time domain near infrared spectroscopy (TD-NIRS) device. The hybrid DCS and TD-NIRS system allows to retrieve information on blood flow, tissue oxygenation, and oxygen metabolic rate. The DCS device performances were estimated in terms of stability, repeatability, ability in retrieving variations of diffusion coefficient, influence of the tissue optical properties, effect of varying count rates and depth sensitivity. Crosstalk between DCS and TD-NIRS optical signals was also evaluated. Finally, in vivo experiments (venous and arterial cuff occlusions on the arm) were conducted to test the ability of the hybrid system in measuring blood flow variations.

17 July 2023 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Caterina AmendolaCaterina Amendola
Caterina Amendola
DCDavide Contini
Davide Contini
Rebecca ReRebecca Re
Rebecca Re
Lorenzo SpinelliLorenzo Spinelli
Lorenzo Spinelli
LFLorenzo Frabasile
Lorenzo Frabasile
Alessandro TorricelliAlessandro Torricelli
Alessandro Torricelli
There is a growing number of applications at both a clinical and consumer level where near infrared spectroscopy (NIRS) is used to noninvasively monitor tissue hemodynamics in skeletal muscle or cerebral cortex. By exploiting the capability of near infrared light to penetrate deeply into biological tissues and the specific spectral features of oxygenated and deoxygenated hemoglobin, it is in fact possible, from light attenuation measurements, to noninvasively estimate the molar concentration of these chromophores in the tissue under investigation, and then retrieve tissue oxygen saturation (StO2). This parameter can be used as a biomarker for physio-pathological conditions in the clinics1 or as an indicator of skeletal muscle fatigue during exercise and sports activities.2 Due to the diffusive nature of biological tissues, StO2 estimate requires either discrimination of absorption and scattering contribution, as provided by the time domain (TD) NIRS or frequency domain (FD) NIRS,3 or the adoption of specific measurement strategy, like in the space-resolved reflectance (SRS) approach.4

1 March 2025 in La Rivista del Nuovo Cimento
Verified
Journal Article
Open access
PDF file
Rebecca ReRebecca Re
Rebecca Re
Lorenzo SpinelliLorenzo Spinelli
Lorenzo Spinelli
FMFabrizio Martelli
Fabrizio Martelli
LSLaura Di Sieno
Laura Di Sieno
IBIlaria Bargigia
Ilaria Bargigia
Alessandro TorricelliAlessandro Torricelli
Alessandro Torricelli
The term diffusive media refers to all the media for which the photon diffusion equation provides an accurate description of light propagation. Indeed, this is the case for a plethora of natural media, such as biological tissues and agricultural products, when illuminated by red and near-infrared light. Diffuse Optics (DO) is the branch of Optics that studies how absorption and scattering phenomena affect light propagation in diffusive media. In this review paper, we present an introduction to time domain (TD) DO, a specific implementation of DO that employs picosecond light pulses, fast and sensitive photodetectors and timing electronics to record the distribution of photon time-of-flight (or photon path lengths) in diffusive media. By interpreting the TD DO signals with the physical model provided by the photon diffusion theory, it is possible to estimate the absorption and scattering properties of the medium that in case of biological tissues can be related to physiological and pathological conditions. We focus on the physical principles of TD DO, the building blocks of TD DO instrumentation, and the applications of TD DO targeting human biological tissues (such as the brain, breast, muscle, and others).

24 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Rebecca ReRebecca Re
Rebecca Re
IPIleana Pirovano
Ileana Pirovano
DCDavide Contini
Davide Contini
Caterina AmendolaCaterina Amendola
Caterina Amendola
LCLetizia Contini
Letizia Contini
Lorenzo SpinelliLorenzo Spinelli
Lorenzo Spinelli
A high power setup for multichannel time-domain (TD) functional near infrared spectroscopy (fNIRS) measurements with high efficiency detection system was developed. It was fully characterized based on international performance assessment protocols for diffuse optics instruments, showing an improvement of the signal-to-noise ratio (SNR) with respect to previous analogue devices, and allowing acquisition of signals with sampling rate up to 20 Hz and source-detector distance up to 5 cm. A resting-state measurement on the motor cortex of a healthy volunteer was performed with an acquisition rate of 20 Hz at a 4 cm source-detector distance. The power spectrum for the cortical oxy- and deoxyhemoglobin is also provided.